Lincoln Electric INVERTEC CC400-T Скачать руководство пользователя страница 6

A-

2

                                                             

INSTALLATION

                                                    A-

2

 

 

Rev. 13 

INVERTEC

®

 CC400-T/TP

 

 

SAFETY PRECAUTIONS 

Read the entire installation section before starting 
installation.

 

 

ELECTRIC SHOCK can kill. 

 

Only qualified personnel should 
perform this installation. 

 

Turn the input power OFF at the 
main switch or fuse box before 
working on this equipment. Turn 

off the input power to any other equipment 
connected to the welding system at the main 
switch or fuse box before working on the 
equipment. 

 

Do not touch electrically 

“Hot” parts. 

 

Always connect the INVERTEC

®

 grounding lug 

(located at the rear of the case) to a proper safety 

(Earth) ground.

 

INVERTEC

®

 is for use on a 4 wire 

system with earthed neutral.

 

 

SELECT SUITABLE LOCATION 

This power source should not be subjected to falling 
water, nor should any parts of it be submerged in water. 
Doing so may cause improper operation as well as pose 
a safety hazard. The best practice is to keep the machine 
in a dry, sheltered area. 
 

 

The bottom of machine must always be placed on a 
firm, secure, level surface. There is a danger of the 
machine toppling over if this precaution is not taken. 

 
Place the welder where clean cooling air can freely 
circulate in through the back louvers and out through the 
case sides. Water,dirt, dust or any foreign material that 
can be drawn into the welder should be kept to a 
minimum. Failure to observe these precautions can result 
in excessive operating temperatures and nuisance 
shutdowns. 
 

Locate the INVERTEC

®

 machine away from radio 

controlled machinery. Normal operation of the welder 
may adversely affect the operation of RF controlled 
equipment, which may result in bodily injury or damage to 
the equipment. 
 
 

INPUT POWER AND GROUNDING 
CONNECTION 

 

Only a qualified electrician should connect the input 

leads to the INVERTEC

®

. Connections should be 

made in accordance with the connection diagram. 
Failure to do so may result in bodily injury or death. 

 
Open the input box on the rear of the case. Use a three-
phase supply line, the three live wires should go through 
the three holes of the input wire holder and be securely 
clamped and fixed. Connect L1, L2, L3 and ground 
according to the Input Supply Connection Diagram decal, 

refer to Figure A.1 on this page. 
 
Make sure the amount of power available from the input 
connection is adequate for normal operation of the 
machine. Refer to the Technical Specifications at the 
beginning of this Installation section for recommended  
fuse and wire sizes. Fuse the input circuit with the 
recommended super lug fuse or delay type breakers. 
Using fuses or circuit breakers smaller than 
recommended may result in “nuisance” shut-offs from 
welder inrush currents, even if the machine is not being 
used at high currents. 

 

CABLECONNECTIONS

 

 
Connect electrode and work leads with sufficient size 
between the proper output studs on the power source 
and the electrode or the work.  Be sure the connection to 
the work makes tight metal to metal electrical contact.  
Poor work lead connections can result in poor welding 
performance. 
 
To avoid interference problems with other equipment 
 and to achieve the best possible operation, route all 
cables directly to the electrode and the work. Avoid 
excessive lengths and do not coil excess cable. 
 
Cable sizes are increased for greater lengths primarily for 
the purpose of minimizing voltage drop in the cable. 
 
Minimum work and electrode cable sizes are as follows: 

TABLE A.1 

Current (60% Duty Cycle) 

Minimum Copper 

Work Cable Size 

 

200A 
300A 
400A 

Up To 30m Length 

30 mm

2

 

50 mm

2

 

70 mm

 
Note: The recommended cable size may need to change 
depending on its quality. When the rated current flow 
goes through, the total voltage drop on the ground cable 
and electrode cable must not exceed 4 volts. 

 

 

    WARNING

 

 

    CAUTION

 

 

    WARNING

 

 

 

 

FIGURE A.1  

Содержание INVERTEC CC400-T

Страница 1: ...07 www lincolnelectric com cn Copyright 2018 The Shanghai Lincoln Electric Company Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind However your overall safety can be increased by proper installation and thoughtful operation on you part DO NOT INSTALL OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MENUAL AND THE SAFETY PRECAUTIONS CON...

Страница 2: ...se record your equipment identification information in the table below Model Name Code Serial Number can be found on the machine rating plate Model Name INVERTEC CC400 T INVERTEC CC400 TP Code Serial number K60098 1 K60098 3 Date Where Purchased Authorized dealer s shop Declaration of conformity THE SHANGHAI LINCOLN ELECTRIC COMPANY Designed in conformance with the following norm GB15579 1 EN 6097...

Страница 3: ...le non flammable screening and or warn them not to watch the arc nor expose themselves to the arc rays or to hot spatter or metal ELECTRIC SHOCK can kill 3 a The electrode and work or ground circuits are electrically hot when the welder is on Do not touch these hot parts with your bare skin or wet clothing Wear dry hole free gloves to insulate hand 3 b Insulate yourself from work and ground using ...

Страница 4: ... equipment in accordance with the national standards and the menufacturer s recommendations WELDING SPARKS can cause fire or explosion 6 a Remove fire hazards from the welding area If this is not possible cover them to prevent the welding sparks from starting a fire Remember that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas Avoid w...

Страница 5: ...10 2 V 26V RECOMMENDED INPUT WIRE AND FUSE SIZES INVERTEC CC400 T TP Input Voltage Frequency Hz 380 415V Maximum Input Ampere 30 28A Maximum Effective Supply Current 23 22A 60 C Copper Wire in Conduct Sizes 6mm2 Fuse or Breaker Size Super Lag 40A Grounding Conductor Size 4mm2 PHYSICAL DIMENSIONS INVERTEC CC400 T TP Height 480mm Width 350mm Depth 730mm Weight 34Kg Temperature Range Operating Temper...

Страница 6: ...nnections should be made in accordance with the connection diagram Failure to do so may result in bodily injury or death Open the input box on the rear of the case Use a three phase supply line the three live wires should go through the three holes of the input wire holder and be securely clamped and fixed Connect L1 L2 L3 and ground according to the Input Supply Connection Diagram decal refer to ...

Страница 7: ...mal protection device When the machine has gone into thermal overload the output will be turned off and the thermal indicator light will be turned ON When the machine has cooled to a safe temperature the Thermal Indicator Light will go out and the machine may resume normal operation Note The machine s welding output will be available after a thermal protection shutdown GENERAL DESCRIPTION The INVE...

Страница 8: ...iper 76 C Output control pot H 75 D Output control trigger return 2 E Output control trigger 4 F Ground lead case G2 15 POSITIVE OUTPUT TERMINAL Note For positive polarity welding connect the electrode cable to the positive terminal and the work cable to the negative terminal For negative polarity welding reverse the electrode and work cables REAR PANEL PLEASE SEE FIGURE B 2 16 INPUT BOX This insu...

Страница 9: ...erface Output Current knob the Remote command will adjust the output current from a minimum of 5A to a maximum of 100A 4 Step and Spot functions are invaild remote command adjustment could be prohibited in function menu Please refer to function menu setting for detailed operation THERMAL LED This indicator will turn on when the machine is overheated and the output has been disabled immediately to ...

Страница 10: ...tivated the LED next to the button is turned ON Range of low frequency mode 0 2Hz 20Hz Range of high frequency mode 10 Hz 300 Hz In the modes of this function will be prohibited When Pulse is active is possible to set Duty cycle Frequency Hz and Background parameters Parameter adjustment knob It is used to set the Output Current used during welding This knob is also a multi purpose command V A Dis...

Страница 11: ...welding can be operated normally 4 If the arc starting fails then repeat the steps above HF TIG GTAW welding To select HF TIG welding Action Visualization Press MODE several times until the LED above lights up When the mode button is in HF TIG position the stick welding functions are disabled and the machine is ready for HF TIG welding During the HF TIG mode the TIG arc is started by HF without pr...

Страница 12: ...w Gas Gas Post flow 2 Step Trigger Sequence To select 2 Step sequence Action Visualization Press crater button until the LED above lights up With the 2 step trigger mode and a TIG welding mode selected the following welding sequence will occur 1 Press and hold the TIG torch trigger The machine will open the gas valve to start the flow of the shielding gas After the Pre flow time to purge air from ...

Страница 13: ...trigger during the downslope time the output current changes into the Crater current immediately When the trigger is released the output will turn OFF at the releasing point the downslope time is not over the output current keeps the crater current for the left time When the downslope time is over the machine is shut down Setup menu To enter the Setup menu Action At idle before welding Voltage Pre...

Страница 14: ...s closed and released quickly in the third step the welding current will be switched to second current value and then if the trigger is closed and released again quickly the welding current will be switched to the preset peak current and then if the trigger is closed consistently the welding will get into crater current This function is only available in non pulse and 4 step modes Factory default ...

Страница 15: ...95 1 50 Current selected value Frequency Not Current selected value Hz LF 0 2 20Hz 0 1Hz 2Hz HF 10 300Hz 1Hz 30Hz Background 0 100 1 50 Current selected value Downslope 0 15S 0 1S 0 5S Current selected value s Crater 0 100 1 50 Current selected value Postflow 0 1 15S 0 1S 0 5S Current selected value s SMAW Uo Set Current 5 400A 1A 150A Current selected value A Hot start 0 10 1 0 Current selected v...

Страница 16: ...the main power switch in control box of power cabin is turned on Thermal LED is lit 1 Check for proper fan operation Fan should run whenever output power is on Check for material blocking intake or exhaust louvers or for excessive dirt clogging cooling channels in machine 2 Machine may have been operated above it s duty cycle Clear obstruction or repair fan After machine has cooled reduce load dut...

Страница 17: ... board in machine is at fault contact an authorized Lincoln Electric Service facility for technical assistance Remote output control not functioning The machine operates normally on LOCAL control 1 Make sure the Local Remote switch is in the REMOTE position 2 The remote control device may be faulty Replace 3 The Local Remote switch must be in the LOCAL position unless a remote control device is at...

Страница 18: ...ssistance Observe all Safety Guidelines detailed in the beginning and throughout this menual Problems Symptoms Possible Areas of Misadjustment s Recommended Course of Action smaller 3 The harnesses aren t connected tightly 4 The arc striking coil is broken Note too bigger gap will make the control circuit damaged Reconnection Note the high voltage on the high frequency arc striking generator conta...

Страница 19: ...J0 6 J0 5 J4 J1M J1 2 J1 3 P 4 2 75 76 77 GND 24xA W G28 252 253 260 261 260A 261A 2 38 239 239 Black Red VIEW OF CONNECTOR ON PC BOARD ELECTRICAL SYMBOLS PER E1537 OHMS WATTS COMPONENT VALUE UNITS RESISTORS MFD VOLTS CAPACITORS 8 LATCH 0F CONNECTOR J5 EXAMPLE THIS IS PIN 7 3 2 LEAD COLORING CODE B BLACK 2 1 8 G GREEN O ORANGE R RED CONNECTOR PIN NUMBERS 7 14 U BLUE Y YELLOW W WHITE 1 3 J5 N BROWN...

Страница 20: ...E 1 NOTES E 1 Rev 13 INVERTEC CC400 T TP World s Leader in Welding and Cutting THE SHANGHAI LINCOLN ELECTRIC COMPANY No 195 Lane 5008 Hu Tai Rd Baoshan Shanghai PRC 201907 www lincolnelectric com cn ...

Страница 21: ... INVERTEC CC400 T Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies ...

Страница 22: ...P 7011 Rev 01 PA 1 INVERTEC CC400 T 2017 04 ILLUSTRATION OF SUB ASSEMBLIES V IV III I II Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies ...

Страница 23: ...ssemblies page and the table below to determine which sub assembly page and column the desired part is located on for your particular code machine SUB ASSEMBLY ITEM NO Ⅰ Ⅱ Ⅲ Ⅳ Ⅴ SUB ASSEMBLY PAGE NAME Case Front Assembly Divider Panel Assembly Base Center Assembly Case Back Assembly Wraparound Assembly PAGE NO PB 1 PC 1 PD 1 PE 1 PF 1 CODE NO 76211 1 1 1 1 1 Illustration of Sub Assemblies Illustra...

Страница 24: ...embly PB 1 INVERTEC CC400 T 2017 04 1 4 5 6 7 8 7 9 11 10 2 3 8c 9b 11a 11b 12 12c Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies Part Numbers Part Numbers Part Numbers Part Numbers ...

Страница 25: ...sher Not Shown S26638 1 4 X 8e M3 Lock Washer Not Shown S26639 1 4 X 8f M3 Hex Nut Not Shown S26640 1 4 X 9 Control Board Assembly S29845 1 X 9a Button Cap Not Shown S28768 X 1 5 X 9b M4x10 Combined Screw S28798 3 4 X 10 Switch Cover S27281 1 X 11 Line Switch S27016 1 X 11a M5x12 Combined Screw S28798 4 2 X 11b Din Rail S27200 1 X 12 Switch Bracket M21705 1 X 12a M4 Plain Washer Not Shown S26638 2...

Страница 26: ...VERTEC CC400 T 2017 04 2 3 5 6 7 8a 8c 8b 8f 1b 1c 1c 2a 1 3a 2a 2 6a 7a 9 9a 10a 10b 10c 10d 11 4 Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies Part Numbers Part Numbers Part Numbers Part Numbers ...

Страница 27: ...1 1 X 8a Resistor M20716 3 1 X 8b Spacer S26157 2 X 8c M5x76 Hex Washer Head Screw S26641 20 1 X 8d M5 Plain Washer Not Shown S26638 3 1 X 8e M5 Lock Washer Not Shown S26639 3 1 X 8f M5 Hex Nut S26640 3 1 X 9 Auxiliary Transformer M21437 15 1 X 9a M5x12 Combined Screw S28798 4 2 X 9b Aux Transformer Harness J1 Not Shown G6043 39 1 X 10 Pre charge and Capacitor Assembly Includes M22737 1 1 X 10a Pr...

Страница 28: ...6 7 6 8 5 11 12 13 14 5 17 15 18 19 3a 3b 3e 4a 4a 6a 6a 8a 9 9a 10a 10 11a 12a 12d 14a 16 16a 17a 5 19a 19d 15a 15a 5a 21 5a 1 Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies Part Numbers Part Numbers Part Numbers Part Numbers ...

Страница 29: ...Washer Not Shown S26638 3 4 X 11c M5 Lock Washer Not Shown S26639 3 4 X 11d M5 Hex Nut Not Shown S26640 3 4 X 11e Ferrite Core Not Shown S28558 7 4 X 11f Ferrite Core Not Shown S28558 5 2 X 12 Shunt S26194 2 1 X 12a M8x40 Hex Head Screw S26641 9 2 X 12b M8 Plain Washer Not Shown S26638 4 4 X 12c M8 Lock Washer Not Shown S26639 4 2 X 12d M8 Hex Nut S26640 4 2 X 12e Shunt Harness Not Shown Includes ...

Страница 30: ...Arc Start Coil M25155 2 1 X 19a M8x25 Hex Head Screw S26641 8 2 X 19b M8 Plain Washer Not Shown S26638 4 4 X 19c M8 Lock Washer Not Shown S26639 4 2 X 19d M8 Hex Nut S26640 4 2 X 20 Output MOV Assembly Not Shown S27147 6 1 X 21 Insulation Paper E4450 11 0 2m X NOTE Use only the parts marked X in the column under the heading number called for in the model index page NSS Not Sold Separately Index of...

Страница 31: ...ack Assembly PE 1 INVERTEC CC400 T 2017 04 Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies Part Numbers Part Numbers Part Numbers Part Numbers 1 2 3 5 6 7 4 4b 6a 7a 8 8a 5a ...

Страница 32: ...639 2 2 X 5d M4 Hex Nut Not Shown S26640 2 2 X 5e Input Snubber Assembly Not Shown S26781 2 1 X 6 Input Supply Box M20720 2 1 X 6a M4x30 Hex Head Screw S26641 3 2 X 6b M4 Plain Washer Not Shown S26638 2 2 X 6c M4 Lock Washer Not Shown S26639 2 2 X 7 Input Holder Base M20720 5 1 X 7a M3x10 Combined Screw S28798 6 2 X 8 Input Holder Cover M20720 4 1 X 8a M4x30 Hex Head Screw S26641 3 2 X 9 Ground De...

Страница 33: ...1 Wraparound Assembly PF 1 INVERTEC CC400 T 2017 04 1 2 3 4 5 6 7 Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies Part Numbers Part Numbers Part Numbers Part Numbers ...

Страница 34: ...26738 2 2 X 3 Case Top G5878 1 1 X 3a M5x12 Hex Washer Head Philips Screw Not Shown S26641 4 8 X 3b ST4 8x13 Hex Self Tapping Screw Not Shown S26738 2 2 X 4 Wiring Diagram NSS 1 X 5 Label Case Top M20952 1 X 6 LE Logo NSS 2 X 7 INVERTEC Family Nameplate NSS 2 X NOTE Use only the parts marked X in the column under the heading number called for in the model index page NSS Not Sold Separately Index o...

Страница 35: ... INVERTEC CC400 TP Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies ...

Страница 36: ...P 7013 Rev 01 PA 1 INVERTEC CC400 TP 2017 04 ILLUSTRATION OF SUB ASSEMBLIES V IV III I II Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies ...

Страница 37: ...Assemblies page and the table below to determine which sub assembly page and column the desired part is located on for your particular code machine SUB ASSEMBLY ITEM NO Ⅰ Ⅱ Ⅲ Ⅳ Ⅴ SUB ASSEMBLY PAGE NAME Case Front Assembly Divider Panel Assembly Base Center Assembly Case Back Assembly Wraparound Assembly PAGE NO PB 1 PC 1 PD 1 PE 1 PF 1 CODE NO 76213 1 1 1 1 1 Illustration of Sub Assemblies Illustr...

Страница 38: ...mbly PB 1 INVERTEC CC400 TP 2017 04 1 4 5 6 7 8 7 9 11 10 2 3 8c 9b 11a 11b 12 12c Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies Part Numbers Part Numbers Part Numbers Part Numbers ...

Страница 39: ... M3 Plain Washer Not Shown S26638 1 4 X 8e M3 Lock Washer Not Shown S26639 1 4 X 8f M3 Hex Nut Not Shown S26640 1 4 X 9 Control Board Assembly S29846 1 X 9a Button Cap Not Shown S28768 X 1 6 X 9b M4x10 Combined Screw S28798 3 4 X 10 Switch Cover S27281 1 X 11 Line Switch S27016 1 X 11a M5x12 Combined Screw S28798 4 2 X 11b Din Rail S27200 1 X 12 Switch Bracket M21705 1 X 12a M4 Plain Washer S26638...

Страница 40: ...ERTEC CC400 TP 2017 04 2 3 5 6 7 8a 8c 8b 8f 1b 1c 1c 2a 1 3a 2a 2 6a 7a 9 9a 10a 10b 10c 10d 11 4 Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies Part Numbers Part Numbers Part Numbers Part Numbers ...

Страница 41: ... X 8a Resistor M20716 3 1 X 8b Spacer S26157 2 X 8c M5x76 Hex Washer Head Screw S26641 20 1 X 8d M5 Plain Washer Not Shown S26638 3 1 X 8e M5 Lock Washer Not Shown S26639 3 1 X 8f M5 Hex Nut S26640 3 1 X 9 Auxiliary Transformer M21437 15 1 X 9a M5x12 Combined Screw S28798 4 2 X 9b Aux Transformer Harness J1 Not Shown G6043 39 1 X 10 Pre charge and Capacitor Assembly Includes M22737 3 1 X 10a Pre c...

Страница 42: ...6 7 6 8 5 11 12 13 14 5 17 15 18 19 3a 3b 3e 4a 4a 6a 6a 8a 9 9a 10a 10 11a 12a 12d 14a 16 16a 17a 5 19a 19d 15a 15a 5a 21 5a 1 Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies Part Numbers Part Numbers Part Numbers Part Numbers ...

Страница 43: ... Washer Not Shown S26638 3 4 X 11c M5 Lock Washer Not Shown S26639 3 4 X 11d M5 Hex Nut Not Shown S26640 3 4 X 11e Ferrite Core Not Shown S28558 7 4 X 11f Ferrite Core Not Shown S28558 5 2 X 12 Shunt S26194 2 1 X 12a M8x40 Hex Head Screw S26641 9 2 X 12b M8 Plain Washer Not Shown S26638 4 4 X 12c M8 Lock Washer Not Shown S26639 4 2 X 12d M8 Hex Nut S26640 4 2 X 12e Shunt Harness Not Shown Includes...

Страница 44: ... Arc Start Coil M25155 2 1 X 19a M8x25 Machine Screw S26641 8 2 X 19b M8 Plain Washer Not Shown S26638 4 4 X 19c M8 Lock Washer Not Shown S26639 4 2 X 19d M8 Hex Nut S26640 4 2 X 20 Output MOV Assembly Not Shown S27147 6 1 X 21 Insulation Paper E4450 11 0 2m X NOTE Use only the parts marked X in the column under the heading number called for in the model index page NSS Not Sold Separately Index of...

Страница 45: ...ack Assembly PE 1 INVERTEC CC400 TP 2017 04 Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies Part Numbers Part Numbers Part Numbers Part Numbers 1 2 3 5 6 7 4 4b 6a 7a 8 8a 5a ...

Страница 46: ...9 2 2 X 5d M4 Hex Nut Not Shown S26640 2 2 X 5e Input Snubber Assembly Not Shown S26781 2 1 X 6 Input Supply Box M20720 2 1 X 6a M4x30 Hex Head Screw S26641 3 2 X 6b M4 Plain Washer Not Shown S26638 2 2 X 6c M4 Lock Washer Not Shown S26639 2 2 X 7 Input Holder Base M20720 5 1 X 7a M3x10 Combined Screw S28798 6 2 X 8 Input Holder Cover M20720 4 1 X 8a M4x30 Hex Head Screw S26641 3 2 X 9 Ground Deca...

Страница 47: ...1 Wraparound Assembly PF 1 INVERTEC CC400 TP 2017 04 1 2 3 4 5 6 7 Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies Index of Sub Assemblies Part Numbers Part Numbers Part Numbers Part Numbers ...

Страница 48: ...26738 2 2 X 3 Case Top G5878 1 1 X 3a M5x12 Hex Washer Head Philips Screw Not Shown S26641 4 8 X 3b ST4 8x13 Hex Self Tapping Screw Not Shown S26738 2 2 X 4 Wiring Diagram NSS 1 X 5 Label Case Top M20952 1 X 6 LE Logo NSS 2 X 7 INVERTEC Family Nameplate NSS 2 X NOTE Use only the parts marked X in the column under the heading number called for in the model index page NSS Not Sold Separately Index o...

Отзывы: