B-1
OPERATION
B-1
Rev. 13
INVERTEC
®
CC400-T/TP
SAFETY PRECAUTIONS
Read this entire section of the operating
instructions before operating the machine.
ELECTRIC SHOCK can kill.
Do not touch electrically live
parts or electrode with skin or
wet clothing.
Insulate yourself from work and
ground.
Always wear dry insulating gloves.
FUMES AND GASES can be
dangerous.
Keep your head out of fumes.
Use ventilation or exhaust to
remove fumes from breathing
zone.
WELDING SPARKS can cause fire
or explosion.
Keep flammable material away.
Do not weld on closed
containers.
ARC RAYS can burn eyes and
skin.
Wear eye, ear and body
protection.
PLEASE SEE ADDITIONAL WARNING
INFORMATION AT THE FRONT OF THIS
OPERATOR’S MENUAL.
DUTY CYCLE
The duty cycle of a welding machine is the percentage of
time in a 10 minute cycle at which the welder can operate
the machine at rated welding current.
60% duty cycle:
Weld for 6 minutes
Break for 4 minutes
Excessive extension of the duty cycle may cause the
thermal protection circuit to activate.
THERMAL PROTECTION
The INVERTEC
®
machine is equipped with a thermal
protection device. When the machine has gone into
thermal overload, the output will be turned off and the
thermal indicator light will be turned
“ON“. When the
machine has cooled to a safe temperature, the Thermal
Indicator Light will go out and the machine may resume
normal operation.
Note:
The machine
’s welding output will be available after a
thermal protection shutdown.
GENERAL DESCRIPTION
The INVERTEC CC400-T/-TP is a 400A arc welding
power source that utilizes three phases input power, to
produce constant current output. The welding response of
this INVERTEC has been optimized for stick (SMAW) and
TIG (GTAW).
OPERATIONAL FEATURES AND
CONTROLS
FRONT PANEL (SEE FIGURE B.1)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
FIGURE B.1
1. ON/OFF POWER SWITCH
Place the lever in the upside position to energize the
machine. When the power is on the output will be
energized in STICK mode.Thermal indicator and alarm
light will keep blinking for a while and fan will start to run.
2. PULSE FREQUENCY SELECTION
This knob is used for pulse frequency selection
(INVERTEC
®
CC400-T has no such selction)
3. CRATER MODE SELECTION
This knob is used for 2T/4T selection.
4. PARAMETER SELECTION
This knob is used for parameter selection.
5. MODE SELELCTION
This knob is used for welding mode selection.
WARNING