background image

D-1

MAINTENANCE

D-1

INVERTEC®  100S

SAFETY PRECAUTIONS

ELECTRIC SHOCK

can kill.

• Have an electrician install and serv-

ice this equipment.

• Turn the input power off at the fuse

box, disconnect supply lines and
allow machine to sit for five minutes
minimum to allow the power capaci-
tors to discharge before working
inside this equipment.

• Do not touch electrically hot parts.

------------------------------------------------------------

INPUT FILTER CAPACITOR

DISCHARGE PROCEDURE

For any maintenance or repair operations it is recom-
mended  to  contact  the  nearest  technical  service  cen-
ter  or  Lincoln  Electric.    Maintenance  or  repairs  per-
formed  by  unauthorized  service  centers  or  personnel
will null and void the manufacturers warranty.

The  machine  has  internal  capacitors  which  are
charged to a high voltage during power-on conditions.
This  voltage  is  dangerous  and  must  be  discharged
before  the  machine  can  be  serviced.    Discharging  is
done  automatically  by  the  machine  each  time  the
power  is  switched  off.    However,  you  must  allow  the
machine  to  sit  for  at  least  5  minutes  to  allow  time  for
the process to take place.

------------------------------------------------------------------------

ROUTINE MAINTENANCE

The  frequency  of  the  maintenance  operations  may
vary  in  accordance  with  the  working  environment.
Any  noticeable  damage  should  be  reported  immedi-
ately.

• Check cables and connections integrity.  Replace, if

necessary.

• Clean  the  power  source  inside  by  means  of  low  -

pressure compressed air.

• Keep  the  machine  clean.  Use  a  soft  dry  cloth  to

clean the external case, especially the airflow inlet /
outlet louvers

Do not open this machine and do not introduce any-

thing into its openings.  Power supply must be discon-
nected  from  the  machine  before  each  maintenance
and service.  After each repair, perform proper tests to
ensure safety.

Power supply must be disconnected from the machine
before  each  maintenance  and  service.   Always  use
gloves in compliance with the safety standards.

------------------------------------------------------------

WARNING

WARNING

CAUTION

WARNING

WARNING

Содержание INVERTEC 100S

Страница 1: ...9 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind However your overal...

Страница 2: ...KER WEARERS SHOULD CONSULT WITH THEIR DOCTOR bEFORE OPERATING Read and understand the following safety highlights For additional safety information it is strongly recommended that you purchase a copy...

Страница 3: ...cooling 3 h Never simultaneously touch electrically hot parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welder...

Страница 4: ...s to adjacent areas Avoid welding near hydraulic lines Have a fire extinguisher readily available 6 b Where compressed gases are to be used at the job site special precautions should be used to preven...

Страница 5: ...opri s et non inflammables 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise paisse pa...

Страница 6: ...he situation with the technical assistance of the manufacturer In some cases this remedial action may be as simple as earthing grounding the welding circuit see Note In other cases it could involve co...

Страница 7: ...s Welding Cables The welding cables should be kept as short as possible and should be positioned close together running at or close to floor level Equipotential Bonding Bonding of all metallic compone...

Страница 8: ..._______________________ Date Purchased___________________________________________________________________________ Where Purchased_______________________________________________________________________...

Страница 9: ...B 2 Making the Weld B 3 B 4 ________________________________________________________________________ Accessories Section C Optional Accessories and Compatible Equipment C 1 Factory Field Installed C...

Страница 10: ...SIONS TEMPERATURE RANGES OPERATING TEMPERATURE RANGE 10 C to 40 C STORAGE TEMPERATURE RANGE 25 C to 55 C RECOMMENDED INPUT WIRE AND FUSE SIzES FOR MAXIMUM RATED OUTPUT INPUT VOLTAGE FREQUENCY Hz 120 6...

Страница 11: ...ay result in injury or equipment damage Read the section on electromagnetic compatibility in this manual Do not operate in areas with an ambient tempera ture greater than 40 C STACKING The INVERTEC 10...

Страница 12: ...RTEC 100S A 3 120V INPUT The rated output of the Invertec 100S is available when connected to a 20A branch circuit When con nected to a branch circuit with lower ampacity lower welding current and dut...

Страница 13: ...exhaust to remove fumes from breathing zone ARC RAYS can burn Wear eye ear and body protection WELDING CUTTING and GOUGING SPARKS can cause fire or explosion Keep flammable material away Do not weld c...

Страница 14: ...is established in this gap and is held and moved along the joint to be welded melting the metal as it is moved ELECTRIC ARC See Figure B 4 Action that takes place in the electric arc FIGURE b 4 CONTR...

Страница 15: ...well as hot and cannot be looked at with the naked eye without risking painful injury A very dark lens specifically designed for arc welding must be used with a hand or face shield whenever viewing th...

Страница 16: ...way of an electric arc Unlike stick welding in which the electrode is consumed in the arc the tung sten electrode is not consumed Instead filler metal is added to the weld by manually dipping a filler...

Страница 17: ...82 11 25 0 Ft 1 Piece Cable K1782 13 12 5 Ft 1 Piece Ultra Flex Cable K960 2 TIG Torch Adapter for connection of PTA 17V torches 1 piece cable to power sources without gas passing through the Twist Ma...

Страница 18: ...can be serviced Discharging is done automatically by the machine each time the power is switched off However you must allow the machine to sit for at least 5 minutes to allow time for the process to...

Страница 19: ...beled POSSIBLE CAUSE lists the obvious external possibilities that may contribute to the machine symptom Step 3 RECOMMENDED COURSE OF ACTION This column provides a course of action for the Possible Ca...

Страница 20: ...gh progression speed 2 Welding current too low 3 Narrow chamfering 1 Arc too short 2 Current too low 1 Humidity in electrode 2 Long arc 1 Current too high 2 Dirty materials 3 Hydrogen in weld present...

Страница 21: ...OF ACTION Oxidation Tungsten inclusions Porosity Hot cracking 1 lnsufficient gas 2 No protection on the back side 1 lncorrect electrode sharpening 2 Electrode too small 3 Operating failure contact of...

Страница 22: ...nit has been operated beyond its capacity rating 2 Airflow through machine is restrict ed or fan has failed 1 Check the output current poten tiometer and replace it if neces sary 2 Verify output cable...

Страница 23: ...may not be accurate for all machines covered by this manual The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels If the diagram is illegible write to...

Страница 24: ...RBEITGEBERS l Do not touch electrically live parts or electrode with skin or wet clothing l Insulate yourself from work and ground l No toque las partes o los elec trodos bajo carga con la piel o ropa...

Страница 25: ...nes de travail l Vermeiden Sie das Einatmen von Schweibrauch l Sorgen Sie f r gute Be und Entl ftung des Arbeitsplatzes l Mantenha seu rosto da fuma a l Turn power off before servic ing l Desconectar...

Страница 26: ...s Leader in Welding and Cutting Products Sales and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectr...

Отзывы: