A-2

INSTALLATION   

INVERTEC® 100S

A-2

Read  entire  installation  section  before  starting
installation.

SAFETY PRECAUTIONS

ELECTRIC SHOCK can kill.

Only qualified personnel should per-
form this installation.

• Disconnect input power by removing

plug  from  receptacle  before  working
inside  INVERTEC®  100S.  Allow
machine  to  sit  for  5  minutes  mini-
mum to allow the power capacitors
to discharge before working inside
this equipment.

Insulate yourself from the work and ground.

Always wear dry insulating gloves.

• Always  connect  the  INVERTEC®  100S  to  a  power

supply  grounded  according  to  the  National
Electrical Code and local codes.

------------------------------------------------------------

SELECT SUITAbLE LOCATION

This machine can operate in harsh environments.  
However,  it  is  important  that  simple  preventative
measures are followed to assure long life and reliable
operation:

• This  machine  must  be  located  where  there  is  free

circulation  of  clean  air  without  restrictions  for  air
movement to and from the air vents.  Do not cover
the machine with paper, cloth or rags when switched
on.

• Dirt  and  dust  that  can  be  drawn  into  the  machine

should be kept to a minimum.

• This  machine  has  a  protection  rating  of  IP21S.

Keep it dry and do not place it on wet ground or in
puddles. Do not use in wet or damp locations. Store
indoors.

• Locate  the  machine  away  from  radio  controlled

machinery.    Normal  operation  may  adversely  affect
the  operation  of  nearby  radio  controlled  machinery,
which  may  result  in  injury  or  equipment  damage.
Read the section on electromagnetic compatibility in
this manual.

• Do  not  operate  in  areas  with  an  ambient  tempera-

ture greater than 40°C.

STACKING

The INVERTEC® 100S  cannot be stacked.

TILTING

Place the machine directly on a secure, level surface.
Do  not  place  or  operate  this  machine  on  a  surface
with  an  incline  greater  than  15°  from  horizontal.  The
machine  may  topple  over  if  this  procedure  is  not  fol-
lowed.

INPUT CONNECTIONS

• 

A grounding conductor is supplied in the
input  cord  and  plug,  it  is  important  that
the supply receptacle ground is connect-
ed. 

------------------------------------------------------------

WARNING

WARNING

INPUT POWER CONNECTION

Check  the  input  voltage,  phase,  and  frequency  sup-
plied to this machine before turning it on.  The allow-
able input voltage is indicated in the technical specifi-
cation section of this manual and on the rating plate of
the machine.  Be sure that the machine is grounded.

Make sure the power available at the input connection
is adequate for normal operation of the machine.  The
fuse  rating  and  cable  sizes  are  both  indicated  in  the
technical specification section of this manual.

Fuse the input circuit with time delay fuses marked “D”
or  delay  type

(1)

circuit  breakers.  Using  fuses  or  circuit

breakers  smaller  than  recommended  may  result  in
“nuisance” shut-offs from welder inrush currents even
if not welding at high currents.

(1)

Also  called  “inverse  time”  or  “thermal/magnetic”  circuit  breakers.

These  circuit  breakers  have  a  delay  in  tripping  action  that
 decreases as the magnitude of the current increases.

The  INVERTEC®  100S  is  recommended  for  use  on
an individual branch circuit.

Содержание INVERTEC 100S

Страница 1: ...9 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind However your overal...

Страница 2: ...KER WEARERS SHOULD CONSULT WITH THEIR DOCTOR bEFORE OPERATING Read and understand the following safety highlights For additional safety information it is strongly recommended that you purchase a copy...

Страница 3: ...cooling 3 h Never simultaneously touch electrically hot parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welder...

Страница 4: ...s to adjacent areas Avoid welding near hydraulic lines Have a fire extinguisher readily available 6 b Where compressed gases are to be used at the job site special precautions should be used to preven...

Страница 5: ...opri s et non inflammables 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise paisse pa...

Страница 6: ...he situation with the technical assistance of the manufacturer In some cases this remedial action may be as simple as earthing grounding the welding circuit see Note In other cases it could involve co...

Страница 7: ...s Welding Cables The welding cables should be kept as short as possible and should be positioned close together running at or close to floor level Equipotential Bonding Bonding of all metallic compone...

Страница 8: ..._______________________ Date Purchased___________________________________________________________________________ Where Purchased_______________________________________________________________________...

Страница 9: ...B 2 Making the Weld B 3 B 4 ________________________________________________________________________ Accessories Section C Optional Accessories and Compatible Equipment C 1 Factory Field Installed C...

Страница 10: ...SIONS TEMPERATURE RANGES OPERATING TEMPERATURE RANGE 10 C to 40 C STORAGE TEMPERATURE RANGE 25 C to 55 C RECOMMENDED INPUT WIRE AND FUSE SIzES FOR MAXIMUM RATED OUTPUT INPUT VOLTAGE FREQUENCY Hz 120 6...

Страница 11: ...ay result in injury or equipment damage Read the section on electromagnetic compatibility in this manual Do not operate in areas with an ambient tempera ture greater than 40 C STACKING The INVERTEC 10...

Страница 12: ...RTEC 100S A 3 120V INPUT The rated output of the Invertec 100S is available when connected to a 20A branch circuit When con nected to a branch circuit with lower ampacity lower welding current and dut...

Страница 13: ...exhaust to remove fumes from breathing zone ARC RAYS can burn Wear eye ear and body protection WELDING CUTTING and GOUGING SPARKS can cause fire or explosion Keep flammable material away Do not weld c...

Страница 14: ...is established in this gap and is held and moved along the joint to be welded melting the metal as it is moved ELECTRIC ARC See Figure B 4 Action that takes place in the electric arc FIGURE b 4 CONTR...

Страница 15: ...well as hot and cannot be looked at with the naked eye without risking painful injury A very dark lens specifically designed for arc welding must be used with a hand or face shield whenever viewing th...

Страница 16: ...way of an electric arc Unlike stick welding in which the electrode is consumed in the arc the tung sten electrode is not consumed Instead filler metal is added to the weld by manually dipping a filler...

Страница 17: ...82 11 25 0 Ft 1 Piece Cable K1782 13 12 5 Ft 1 Piece Ultra Flex Cable K960 2 TIG Torch Adapter for connection of PTA 17V torches 1 piece cable to power sources without gas passing through the Twist Ma...

Страница 18: ...can be serviced Discharging is done automatically by the machine each time the power is switched off However you must allow the machine to sit for at least 5 minutes to allow time for the process to...

Страница 19: ...beled POSSIBLE CAUSE lists the obvious external possibilities that may contribute to the machine symptom Step 3 RECOMMENDED COURSE OF ACTION This column provides a course of action for the Possible Ca...

Страница 20: ...gh progression speed 2 Welding current too low 3 Narrow chamfering 1 Arc too short 2 Current too low 1 Humidity in electrode 2 Long arc 1 Current too high 2 Dirty materials 3 Hydrogen in weld present...

Страница 21: ...OF ACTION Oxidation Tungsten inclusions Porosity Hot cracking 1 lnsufficient gas 2 No protection on the back side 1 lncorrect electrode sharpening 2 Electrode too small 3 Operating failure contact of...

Страница 22: ...nit has been operated beyond its capacity rating 2 Airflow through machine is restrict ed or fan has failed 1 Check the output current poten tiometer and replace it if neces sary 2 Verify output cable...

Страница 23: ...may not be accurate for all machines covered by this manual The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels If the diagram is illegible write to...

Страница 24: ...RBEITGEBERS l Do not touch electrically live parts or electrode with skin or wet clothing l Insulate yourself from work and ground l No toque las partes o los elec trodos bajo carga con la piel o ropa...

Страница 25: ...nes de travail l Vermeiden Sie das Einatmen von Schweibrauch l Sorgen Sie f r gute Be und Entl ftung des Arbeitsplatzes l Mantenha seu rosto da fuma a l Turn power off before servic ing l Desconectar...

Страница 26: ...s Leader in Welding and Cutting Products Sales and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectr...

Отзывы: