IDEALARC DC-600
F-53
TROUBLESHOOTING & REPAIR
SCR / SCR OUTPUT BRIDGE REMOVAL
8.
Lift the SCR Bridge Assembly
straight up and out of the machine
being sure that no leads become
tangled or hooked on the other
machine parts.
a.
Be sure to locate the SCR
Bridge Assembly on a stable
work surface capable of hold-
ing the weight of the assembly.
9.
Remove individual SCR Heat Sinks
following the procedure described
in A above.
10. Replace all insulating materials,
including the insulators on the
frame rail and all insulating tubes,
when installing the SCR Output
Bridge Assembly.
11. The Output Bridge assembly
should be electrically isolated from
ground. Check with an analog ohm
meter. Minimum resistance is
500,000 ohms to ground.
5.
Remove the bolt that connects the
Shunt Assembly (heavy copper)
lead to the SCR Bridge Assembly.
The Shunt Assembly connects the
positive Weld Output Terminal to
the SCR Bridge Assembly.
6.
Remove the small snubber lead
from the left hand (facing the front
of the machine) rear heat sink
mounting bolt using a 1/2" socket
wrench.
7.
Clear all leads from any obstruc-
tions.