IDEALARC DC-600
F-30
TROUBLESHOOTING & REPAIR
TEST PROCEDURES
If LED 1 Does Not Glow When
ON/OFF PUSH BUTTON is Set to ON
1.
Test for 115 VAC between leads
#255 and #256 at Plug J2 on the
Control Board.
a.
Disconnect main AC input sup-
ply power to the machine.
b.
Locate the Control Board in the
Control Box.
c
Disconnect Molex Plug J2.
d.
Insert the probes into the Plug
lead cavities for leads
# 255 and # 256.
e.
Replace the Molex Plug J2.
f.
Connect main AC input power
to the machine.
g.
Set the ON/OFF PUSH BUT-
TON to ON.
h.
Read meter for 115 VAC.
If 115 VAC is present AND LED
1 does not glow, the Control
Board may be faulty. Replace.
If 115 VAC is not present,
• Inspect leads #255 and #256
and associated wiring for loose
or faulty connections. See
wiring diagram.
• Test for continuity (zero
ohms) between lead # 256 at
Plug J2 on the Control Board
and the ON/OFF PUSH BUT-
TON. See Figure F.10.
NOTE: Disconnect main AC
input power to the machine
• Test for continuity (zero
ohms) between lead #256 at
Plug J2 on the Control Board
and lead X2 at the secondary
thermostat. See Figure F.10.
NOTE: Disconnect main AC
input power to the machine.
FIGURE F.10 - LED 1 Test Points
CONTROL BOARD
CONTROL BOARD TEST