IDEALARC DC-600
F-20
TROUBLESHOOTING & REPAIR
b.
If the Firing Board number is
G-1486 - 5 or higher, test for 75
VAC between the leads con-
nected to the firing board
Molex plugs. See Figure F.6.
c.
If one or more of the above
voltage tests are incorrect,
check for loose or faulty wiring.
d.
If the wiring is good, then the
Main Transformer may be
faulty. Replace.
MAIN TRANSFORMER (T1) VOLTAGE TEST
From
Plug Pin Lead
To
Plug Pin Lead
Expected VAC
J5 2 #203
J5 4 #204
75 VAC
J5 7 #205
J5 3 #206
75 VAC
J5 9 #207
J5 8 #208
75 VAC
FIGURE F.6 - Phase Angle Windings Test Points and Firing Board
Location.
FIRING BOARD
CONTROL BOARD
TERMINAL
STRIP
J5
PIN 8
(LEAD #208)
PIN 9
(LEAD #207)
PIN 4
(LEAD #204)
PIN 7
(LEAD #205)
PIN 2
(LEAD #203)
PIN 3
(LEAD #206)