IDEALARC DC-600
F-52
TROUBLESHOOTING & REPAIR
SCR / SCR OUTPUT BRIDGE REMOVAL
NOTE: If it is necessary to remove and
replace the entire SCR Output Bridge
Assembly, use these procedures.
1.
Disconnect the Gate Lead Molex
Plug J4 from the Firing Board (later
models).
a.
If working on an earlier model
and there is no Gate Lead
Molex Board, identify and label
the six Gate leads and cut or
unsolder the leads from their
respective snubber boards.
2.
Remove the four self-tapping bolts
that mount the SCR Bridge
Assembly to the horizontal rails
using a 9/16" socket wrench. See
Figure F.20.
a.
Note placement of insulting
washers, tubes, and pads so
they can be replaced correctly.
3.
Identify and label the six trans-
former secondary (heavy alu-
minum) leads that connect to the
anodes of the SCR Head Sink
Assemblies. See Figure F.20.
4.
Remove the transformer secondary
leads using a 1/2" socket wrench.
FIGURE F.20 - SCR Output Bridge Removal
B. REMOVAL OF COMPLETE BRIDGE ASSEMBLY