FLUX HOPPER
The flux hopper may be mounted on either a horizontal
or vertical tube, or on the wire drive. For the best flow
of flux, keep the hose from the hopper to the nozzle as
vertical as possible.
CABLES
ArcLink Control Cables
ArcLink Control Cables are available in two forms:
• K1543-xx series for most indoor or factory installa-
tions.
• K2683-xx series for outdoor use or when the equip-
ment is frequently moved.
ArcLink/LincNet control cables are special high quality
cables for digital communication. The cables are cop-
per 5 conductor cable in a SO-type rubber jacket.
There is one 20 gauge twisted pair for network commu-
nications. This pair has an impedance of approximate-
ly 120 ohms and a propagation delay per foot of less
than 2.1 nanoseconds. There are two 12 gauge con-
ductors that are used to supply 40VDC to the network.
The fifth wire is 18 gauge and is used as an electrode
sense lead.
Use of non-standard cables may lead to system shut-
downs, poor arc starting and wire feeding problems.
The control cables connect the power source to the
wire feeder, and the wire feeder to other wire feeders.
Control cables may be connected end to end to extend
their length. Use a maximum of 200 feet (61 m) of con-
trol cable between components.
A-12
INSTALLATION
CRUISER
TM
FIGURE A.19 - VERTICAL TUBE MOUNTING
FIGURE A.20 - HORIZONTAL TUBE MOUNTING
FIGURE A.21 - WIRE DRIVE MOUNTING
FIGURE A.22 - ARCLINK CONTROL CABLES
A
B
C
D
E
A
B
C
D
E
Power Source
Wire Feeder
Pin
Function
Pin
Function
A
ArcLink
A
ArcLink
B
ArcLink
B
ArcLink
C
67 voltage sense
C
67 voltage sense
D
40 VDC
D
40 VDC
E
Common
E
Common