9
INSTALLATION
CROSSLINC
™
REMOTE
recoMMenDeD electroDe anD WorK cable
siZes For arc WelDinG
Tabulated below are copper cable sizes recommended for
different currents and duty cycles. Lengths stipulated are the
distance from the welder to work and back to the welder again.
Cable sizes are increased for greater lengths primarily for the
purpose of minimizing cable drop.
** Tabled values are for operation at ambient temperatures of 40°C and
below. Applications above 40°C may require cables larger than recom-
mended, or cables rated higher than 75°C
RECOMMENDED CABLE SIZES (RUBBER COVERED COPPER - RATED 75°C)**
AMPERES
PERCENT DUTY
CYCLE
CABLE SIZES FOR COMBINED LENGTHS OF ELECTRODE AND WORK CABLES
0 TO 50 FT.
50 TO 100 FT.
100 TO 150 FT. 150 TO 200 FT. 200 TO 250 FT.
200
60
2
2
2
1
1/0
200
100
2
2
2
1
1/0
225
20
4 OR 5
3
2
1
1/0
225
40 & 30
3
3
2
1
1/0
250
30
3
3
2
1
1/0
250
40
2
2
1
1
1/0
250
60
1
1
1
1
1/0
250
100
1
1
1
1
1/0
300
60
1
1
1
1/0
2/0
325
100
2/0
2/0
2/0
2/0
3/0
350
60
1/0
1/0
2/0
2/0
3/0
400
60
2/0
2/0
2/0
3/0
4/0
400
100
3/0
3/0
3/0
3/0
4/0
500
60
2/0
2/0
3/0
3/0
4/0