14
OPERATION
autoMatic tiG
The CrossLinc Remote can automatically optimize the power
source settings for scratch start TIG operation when it is
connected for electrode negative polarity and the power source is
in the SMAW mode. This must be disabled if stick welding with
negative polarity. When in the setup menu for Automatic TIG, the
display will show the following:
FIGURE B.8
Turn the knob to the right to select “Auto” TIG.
Turn the knob to the left to select “off”. This setting must be
turned “off” to stick weld with negative polarity.
The factory default is “Auto”.
VoltaGe calibration
To calibrate the arc voltage display,
before entering the setup
menu:
•
Determine the ratio of the actual arc voltage and the arc
voltage displayed by the CrossLinc Remote.
While in the setup menu, adjust the calibration factor as follows:
Actual arc voltage / displayed arc voltage = calibration factor
(Example: 20.0 / 20.5 = 0.97)
The calibration factor is factory set as 1.00
When in the setup menu for voltage calibration the display will
show the following:
FIGURE B.9
Turn the knob to the right to increase the calibration factor, and to
the left to decrease the calibration factor.
The factory default is 1.00
current calibration
To calibrate the arc current display,
before entering the setup
menu:
•
Determine the ratio of the actual arc current and the arc
current displayed by the CrossLinc Remote.
While in the setup menu, adjust the calibration factor as follows:
Actual arc current / displayed arc current = calibration factor
(Example: 200 / 205 = 0.97)
The calibration factor is factory set as 1.00
When in the setup menu for current calibration the display will
show the following:
FIGURE B.10
Turn the knob to the right to increase the calibration factor, and to
the left to decrease the calibration factor.
The factory default is 1.00.
Factory reset
In order to reset your setup parameters to the factory default, hold
the setup button for 5 seconds while the remote is in an idle state.
While resetting, the displays will show the following. The last digit
is the seconds to reset. At the end of the countdown, the reset
will take place and the display will return to its idle state. If the
setup button is released before the countdown is complete, the
reset will not take place.
FIGURE B.11
voL
CUr
rSt3