DIAGRAMS

F-1

COMMANDER 400

NO

TE:

This diag

ram is f

or ref

erence only

.

It ma

y not be accur

ate f

or all machines co

v

ered b

y

 this man

ual.

The specific dia-

g

ram f

or y

our par

ticular machine is pasted inside the machine on one of the enclosure panels

.

WIRING DIAGRAM:

240 uF

240 uF

240 uF

STATOR

ASSEMBLY

RECTIFIER

SHUNT

600 AMP

CHOKE

OUTPUT

SCR A

SCR B

SCR C

G1

G2

G3

G1

G2

G3

1

2

3

6

8

2

3

1

2

3

204S

206S

204S

206S

207

SNUBBER PC BOARD

1

2

3

221

220

219

218

217

216

215

214

213

222

1

2

3

4

5

6

7

8

9

10

213

214

215

216

217

218

219

220

221

222

261

223

204

50 Ohm

100 W

120 V

WHITE

120/240V

15A

CB4

15A

CB3

CB1

CB2

11

12

9

6A

50A

50A

9

11

12

TERM.

3A

GREEN

GREEN

GREEN

WHITE

BLACK

BLACK

BLACK

8

8

GND-C

GND-D

E1

E2

3

IDLER

SWITCH

AUTO

S4

SWITCH

FINE CONTROL

POT

SELECTOR

S1

4

2

76

75

75

77

77

76B

77B

76

12 VOLT

BATTERY

(+)

(-)

COIL

COIL

PULL

HOLD

SOLENOID

IDLE

ENGINE GROUND 

1

J2

1

3

4

B1

E2

E1

MOTOR

+

-

232

231A

231A

236C

240

234

233A

255

GROUND SCREW

3

GND-E

5C

5A

5

5C

5C

236B

236A

METER

HOUR

SENSOR

SENSOR

FUEL LVL.

S2

232A

239A

229

241

J10

6

WHITE

5E

5G

5G

5E

5H

5H

5C

GROUND SCREW

IN CONTROL BOX

GND-D

GND-C

GND-E

IN CONTROL BOX

6B

3B

S3

START BUTTON

HIGH

3

BLACK

6

BLACK

IN CONTROL BOX

T1

1002

1004

1006

1008

1011

1013

1015

1009

1010

1012

1014

1016

1017

1019

1021

1023

1018

1020

1022

1024

1001

1003

1005

1007

1002

1004

1006

1008

CAPACITOR

T2

T3

S8

W5

CONNECTOR CAVITY NUMBERING SEQUENCE

(VIEWED FROM COMPONENT SIDE OF BOARD)

ELECTRICAL SYMBOLS PER E1537

NEG.

POS.

RUN

STOP

242E

239A

229B

245

243

5

67

8

242D

247

227

239

EXC

NEG

POS

SENSE

226

225

224

STARTER

SOLENOID

ALTERNATOR

242

242

NEXT AVLB.

S6

A

C

B

D

E

F

 AMPHENOL 2

77D

76D

75D

2D

4D

REMOTE

CONTROL

GROUND

TRIGGER

77C

GFCI

LINE

LOAD

LOAD

LINE

HOT

WHITE

WHITE

HOT

227

75B

J12

METER

 PCB

1

2

3

4

1

2

3

4

250

251

252

253

9

8

7

6

5

4

3

2

1

A

226

234

246

242G

1

2

3

4

5

6

SENSOR

SWITCH

SWITCH

228A

241A

229A

239

239B

1

2

3

4

5

6

7

8

ENGINE TO PCB HARNESS

PANEL TO PANEL WIRES

PANEL TO PCB HARNESS

120 V

GFCI

LINE

LOAD

LOAD

LINE

HOT

WHITE

WHITE

HOT

J11

239B

242I

204B

209

9

237

J16

P16

254

COIL

COIL

PULL

HOLD

SOLENOID

SHUTDOWN

256

232

224

242D

76C

228

STARTING

206

6

8

15

16

SPI

SCI

OUTPUT

SOURCE

CONTROL

ALWAYS ON

OUTPUT REMOTELY

CONTROLLED

CW

VIEWED FROM

BACK

11

12

13

14

23

5

6

8

9

4

267

238

262

262

261

204

223

CC

BYPASS PC

BOARD

260

1

2

3

4

5

6

7

8

9

10

270

269

268

272

273

270

269

268

272

273

REMOTE/

LOCAL

SWITCH

GND-F

GND-F

8

7

6

5

204A

2

4

WELDED STUD

ON OUTPUT PANEL

GND-A

DC

DB

DA

DD

AUX. POWER 

B3

B2

4

J30

260

ENGINE PROT.

BOARD

J23

J8

J4

J1

J6

J7

J3

237

274

280

10

207

233

280

279

10

11

256

255

STAINLESS STEEL

STAND-OFF

FRAME GROUND

1

47

12

1

4

47

9

204A

T3

T2

T1

6

5

5A

3

EXCITER

WINDINGS

W1

W5

W2

W6

W3

W3

W6

W1

W4

W2

240

287

SOLENOID GROUND

STUD ON ENGINE

4

279

236A

233A

233

240

240A

MOTHER

CONTROL

PC BOARD

J5

J40

J50

STUD ON ENGINE

MOUNT CHANNEL

ST

UD

ON

ENGINE

CONNECTIONS TO

CAPACITORS MADE

EXC

ITER

V

OLTAG

E

FEEDBACK BOARD

5D

3D

3D

3D

5D

3D

5D

3D

NEUTRAL T2 STUD

T1 INSULATED STUD

     T3

INSULATED STUD

(optional)

232H

CONNECTIONS

WK

G

OIL TEMP. SENSOR & SWITCH

+

-

AMMETER

229A

+

-

+

-

+

-

FUEL

S

SS

228A

241A

232B

TEMP.

232C

232A

242B

242A

242C

LOW

FUEL

LOW

PRESS.

245

OIL

PRESS.

TEMP.

ALT.

243

236C

229B

247

246

238

242G

232E

232G

232F

232D

L11008

COMMANDER 400-STICK MODEL WIRING DIAGRAM

1

2

3

4

5

J60

2

4D

75D

76D

2D

77D

3

4

5

6

1

7

8

6

77C

75B

76C

4B

2B

4B

2B

FRAME GROUND

J61

(VIEWED FROM BACK)

REMOTE PROTECTION PCB

AUXILIARY BYPASS PCB

5J

9A

5K

8A

5J

9A

5K

8A

AUX. CURRENT

SENSE TOROID

8A

5J

9A

5K

8A

5J

9A

5K

B4

B5

B6

B7

9A

5K

5J

8A

5D

274

240A

CONTROL HARNESS

CONTROL HARNESS

CONTROL HARNESS

ENGINE HARNESS TO PANEL WIRES

ENGINE HARNESS

CONTROL PANEL 

GND-H

ON CONTROL PANEL

SMALL

TAB

LARGE

TAB

SILVER

TAB

SILVER

TAB

SILVER

TAB

STUD ON GENERATOR

MOUNT CHANNEL

STAINLESS STEEL

STAND-OFF

FRAME GROUND

STAINLESS STEEL

STAND-OFF

FRAME GROUND

W4

W6

242I

CONNECTIONS ON CONTROL BOARD

(VIEWED AS INSTALLED)

J2

J6

J5

J8

J7

J1

J4

J3

B1

B2

B3

J23

ENGINE

PROT.

BOARD

POSITION   NAMEPLATE SETTING

SELECTOR SWITCH (S8)

1          NO FUNCTION

2       NO FUNCTION

3          90 MAX

4          120 MAX

5          180 MAX

6          230 MAX

7          270 MAX

8          400 MAX

9          50-575

(SEE SELECT SWITCH CHART)

STAINLESS STEEL

   STAND-OFF

COMMON BATT.

285

285

OIL PRESSURE SWITCH

& SENSOR

286

BOLT ONTO

SENDER BRK’T

VIA BOLTED

5-15-98A

Содержание Commander 400

Страница 1: ...IS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT And most importantly think before you act and be careful For use with machines having Code Numbers 9978 10580 S...

Страница 2: ...PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING Read and understand the following safety highlights For additional safety information it is strongly recommended that you pur chase...

Страница 3: ...ical earth ground 3 f Maintain the electrode holder work clamp welding cable and welding machine in good safe operating condition Replace damaged insulation 3 g Never dip the electrode in water for co...

Страница 4: ...vent the welding sparks from starting a fire Remember that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas Avoid welding near hydraulic...

Страница 5: ...pri s et non inflammables 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise paisse pan...

Страница 6: ...e information must be followed to avoid minor personal injury or damage to this equipment CAUTION Please Examine Carton and Equipment For Damage Immediately When this equipment is shipped title passes...

Страница 7: ...Controls B 5 Auxiliary Power Controls B 5 Engine Operation B 6 Starting the Engine B 6 Stopping the Engine B 6 Break In Period B 6 Typical Fuel Consumption B 6 Welder Operation B 7 Stick Welding B 7...

Страница 8: ...mm 1683 lbs 763 kg Stick Wire model OUTPUT WELDER AND GENERATOR Duty Cycle Welding Output Volts at Rated Amps 100 400 amps DC Constant Current 40 volts 400 amps DC Constant Voltage 40 volts 60 500 am...

Страница 9: ...performance the Commander 400 should be run in a level position The maximum angle of operation for the Deutz engine is 20 degrees in a direction to cause the control panel to be angled up 30 degrees f...

Страница 10: ...moke when fueling Fill fuel tank at a moderate rate and do not overfill Wipe up spilled fuel and allow fumes to clear before starting engine Keep sparks and flame away from tank OIL The Commander is s...

Страница 11: ...g the clamp provided secure the outlet pipe to the outlet tube with the pipe positioned such that it will direct the exhaust in the desired direction SPARK ARRESTER Some federal state or local laws ma...

Страница 12: ...h the symbol is provided on the front of the welder AUXILIARY POWER RECEPTACLES The auxiliary power capacity of the Commander 400 is 10 000 watts of 60 Hz single phase power The auxil iary power capac...

Страница 13: ...able of the desired length The 50 amp 120 240 VAC plug is available in the optional K802R plug kit 4 Plug this cable into the 50 Amp 120 240 Volt recep tacle on the Commander 400 case front Figure A 2...

Страница 14: ...f 120 240 volt AC power As a welder it provides up to 400 amps of DC constant current output in six slope controlled ranges In addition a seventh general purpose welding range provides up to 575 amps...

Страница 15: ...nds engine life Single side engine service with over the top access to the engine Copper alternator windings and high temperature insulation for dependability and long life ADDITIONAL DESIGN FEATURES...

Страница 16: ...3 FUEL LEVEL GAUGE AND LIGHT Displays the level of diesel fuel in the 25 gallon fuel tank The yellow light turns on when the fuel gage reaches the reserve level Once the reserve level is reached the...

Страница 17: ...e to a faulty flashing circuit The light will remain on when the engine has been shut down due to a fault in the alter nator regulator or the cooling blower belt 7 IDLER SWITCH Has two positions as fo...

Страница 18: ...2 LOCAL REMOTE SWITCH The toggle switch on the control panel labeled Local Remote gives the operator the option of con trolling the output at the welder control panel or at a remote station For remote...

Страница 19: ...switch to RUN Observe that all engine protection lights momentarily turn on some lights may turn off before starting Check the fuel gauge to make sure that there is an adequate fuel level 6 Press and...

Страница 20: ...venth position of the OUTPUT RANGE switch is designed for horizontal welds with all types of elec trodes especially low hydrogen The OUTPUT CON TROL adjusts the full range of 50 to 575 amps This setti...

Страница 21: ...500 500 750 750 1000 3 3 3 10 20 15 30 25 40 40 55 55 80 80 125 3 8 2 4 5 10 3 5 5 10 3 5 5 10 3 5 13 17 6 8 15 23 7 11 21 25 10 12 23 27 11 13 28 32 13 15 3 8 2 4 5 10 3 5 5 10 3 5 9 13 4 6 11 15 5 7...

Страница 22: ...re model engine to go to the high idle speed the wire will begin to feed and the welding process started When welding is stopped the engine will revert to low idle speed after approximately 15 seconds...

Страница 23: ...different phases and cannot be paralleled The auxiliary power receptacles should only be used with three wire grounded type plugs or approved dou ble insulated tools with two wire plugs The current r...

Страница 24: ...frequent starting below 10 F 12 2 o C Required Ether tank is not provided with kit K899 1 SPARK ARRESTOR KIT Easily mounts to standard muffler K949 1 OIL DRAIN KIT Includes ball valve hose and clamp R...

Страница 25: ...o the Periodic Checks section of the Engine Operator s Manual for the recommended maintenance schedule of the following a Engine Oil and Filter b Air Cleaner c Fuel Filter and Delivery System d Coolin...

Страница 26: ...astic center cap and O ring 3 Remove the large white volume plug located direct ly under the center cap in the upper cavity of the fil ter header Use a small screwdriver or similar device to lift the...

Страница 27: ...e battery holder out from the welder 3 Disconnect the negative battery cable 4 Remove the engine end panel for access to the engine 5 Loosen the alternator mounting bolts and rotate the alternator tow...

Страница 28: ...ent Fuel Filter Element Water Separator Element Fuel Pre Filter Screen Battery MAKE Donaldson AC Lincoln Gates Deutz Purolator Napa Fram Deutz Purolator Napa Fram Lincoln Stanadyne Lincoln Stanadyne P...

Страница 29: ...put problems Step 2 PERFORM EXTERNAL TESTS The second column labeled POSSIBLE AREAS OF MISADJUSTMENT S lists the obvious external possibilities that may con tribute to the machine symptom Perform thes...

Страница 30: ...starting Battery does not stay charged 1 Contact your Local Lincoln Authorized Field Service Facility 1 Battery is low Charge Battery 2 Loose battery cable connections Inspect clean and tighten 1 Out...

Страница 31: ...e when attempting to weld Engine will not go to high idle when using auxiliary power 1 Idler switch in High idle position Set switch to Auto 2 External load on welder or auxil iary power Remove all ex...

Страница 32: ...chapter for proper switch function 1 Local Remote switch is in wrong position Place switch in Local position to control output at welder Place switch in Remote position to control output remotely Ref...

Страница 33: ...9B 242I 204B 209 9 237 J16 P16 254 COIL COIL PULL HOLD SOLENOID SHUTDOWN 256 232 224 242D 76C 228 STARTING 206 6 8 15 16 SPI SCI OUTPUT SOURCE CONTROL ALWAYS ON OUTPUT REMOTELY CONTROLLED CW VIEWED FR...

Страница 34: ...246 232A FUEL 232F LOW FUEL S TEMP OIL TEMP 243 232E S PRESS 229A 242 5K CONTROL 8A REMOTE B CONTROL C 75D D AUXILIARY BYPASS PCB J 9A 5K 5J 8A A GROUND 242I 242H AMPHENOL 2 75E 7 CB5 15AMP REMOTE 2E...

Страница 35: ...ONTROL MODULE Keep away from moving parts ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE Only qualified personnel should instal...

Страница 36: ...DER N A WELDING CABLE MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE APPLICATIONS SEE OPERATING MANUAL 14 PIN S22911 N D ON COMMANDER 400 STICK WIRE THE OUTPUT CONTR...

Страница 37: ...REMOTE OUTPUT CONTROL IS USED PLACE LOCAL REMOTE SWITCH IN REMOTE POSITION COMMANDER 400 STICK WIRE LN 25 ACROSS THE ARC CONNECTION DIAGRAM WITH OPTIONAL K857 REMOTE CONTROL S22912 12 13 96 N A WELDI...

Страница 38: ...O NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN SPARE 82 Only qualified personnel should install use 81 before servicing or service this equipment Keep away from moving parts N C Keep guards in place...

Страница 39: ...OPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE N C IF OPTIONAL REMOTE OUTPUT CONTROL IS USED PLACE LOCAL REMOTE SWITCH IN REMOTE POSITION COMMANDER 400 STICK WIRE LN 7 CONNECTION...

Страница 40: ...EADS AND INSULATE ELECTRODE K867 UNIVERSAL ADAPTER PLUG CAUTION ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN T...

Страница 41: ...AMPHENOL POWER SOURCE FRAME CONNECTION Do not operate with panels open WIRE FEEDER VOLTMETER CONNECTION REMOTE OUTPUT CONTROL CONNECTS TO WORK TERMINAL OF POWER SOURCE TO WIRE FEEDER CAUTION THE ENGI...

Страница 42: ...use or service this equipment TO LN 8 INPUT K595 CONTROL CABLE S22917 CABLE PLUG N B USE VOLTMETER SWITCH TO SELECT DESIRED ELECTRODE POLARITY POSITION THE RANGE SWITCH TO WIRE WELDING CV ELECTRODE C...

Страница 43: ...19 63 23 69 28 99 50 38 54 44 1 26 6 21 96 45 67 CENTER OF GRAVITY WITH OIL IN ENGINE AND FULL FUEL TANK 6 56 63 10 6 55 15 75 14 63 42 00 37 30 45 38 6 53 24 97 BOTTOM VIEW OF WELDER BASE 48 64 10 22...

Страница 44: ...F 12 NOTES F 12 COMMANDER 400...

Страница 45: ...letin ED 80 or call 216 383 2259 and ask for the Welding School Registrar Lincoln Welding School BASIC COURSE 700 00 5 weeks of fundamentals There is a 10 discount on all orders of 50 00 or more for s...

Страница 46: ...electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese del trabajo y...

Страница 47: ...e Be und Entl ftung des Arbeitsplatzes Mantenha seu rosto da fuma a Use ventila o e exhaust o para remover fumo da zona respirat ria Turn power off before servicing Desconectar el cable de ali mentaci...

Страница 48: ...y be used with the environ mental systems described above This includes hoses fil ters belts and hose adapters Expendable Parts Lincoln is not responsible for the replacement of any expendable part th...

Отзывы: