B-4

OPERATION

B-4

WELDING CONTROLS (Items 10 through 19)

10. OUTPUT CONTROL: 

The OUTPUT dial is used to pre-

set the output voltage or current as displayed on the dig-
ital meters for the four welding modes. When in the CC-
STICK, DOWNHILL PIPE or CV-WIRE modes and when
a remote control is connected to the 6-Pin or 14-Pin
Connector, the auto-sensing circuit automatically switch-
es the OUTPUT CONTROL from control at the welder to
the remote control. In the CV-WIRE mode, when the
wire feeder control cable is connected to the 14-Pin
Connector, the auto-sensing circuit automatically makes
OUTPUT CONTROL inactive and the wire feeder volt-
age control active.

When in the TOUCH START TIG mode and when a
Amptrol is  connected to the 6-Pin Connector, the OUT-
PUT dial is used to set the maximum current range of the
CURRENT CONTROL of the Amptrol.

11. DIGITAL OUTPUT METERS: 

The digital meters allow the output voltage (CV-WIRE
mode) or current (CC-STICK, DOWNHILL PIPE and TIG
modes) to be set prior to welding using the OUTPUT con-
trol knob. During welding, the meters display the actual
output voltage (VOLTS) and current (AMPS). A memory
feature holds the display of both meters on the seven
seconds after welding is stopped. This allows the opera-
tor to read the actual current and voltage just prior to
when welding was ceased. While the display is being held
the left-most decimal point in each display will be flashing.
The accuracy of the meters is ± 3%.

12. WELD

MODE

SELECTOR

SWITCH:

(Provides four selectable welding modes)

CV-WIRE
DOWNHILL PIPE
CC-STICK
TOUCH START TIG

13. ARC

CONTROL:

The ARC

CONTROL WIRE/STICK knob is active in the

WIRE and STICK modes, and has different functions in
these modes. This control is not active in the TIG mode.

CC-STICK mode: In this mode, the ARC CONTROL knob
sets the short circuit current (arc-force) during stick
welding. Increasing the number from -10(Soft) to
+10(Crisp) increases the short circuit current and prevents
sticking of the electrode to the plate while welding.

This can also increase spatter. It is recommended that the
ARC

CONTROL be set to the minimum number without

electrode sticking. Start with a setting at 0. 

DOWNHILL PIPE mode: In this mode, the ARC CONTROL
knob sets the short circuit current (arc-force) during stick
welding to adjust for a soft or a more forceful digging arc
(Crisp). 

Increasing the number from -10(Soft) to +10(Crisp) increas-
es the short circuit current which results in a more forceful
digging arc. Typically a forceful digging arc is preferred for
root and hot passes. A softer arc is preferred for fill and cap
passes where weld puddle control and deposition (“stack-
ing” of iron) are key to fast travel speeds. It is recommended
that the ARC CONTROL  be set initially at 0.

The OUTPUT dial is used to preset the output voltage or

current as displayed on the digital meters for the five weld-
ing modes. When in the CC-STICK, ARC GOUGING or CV-
WIRE modes and when a remote control is connected to the
6-Pin or 14-Pin Connector, the auto-sensing circuit automat-
ically switches the OUTPUT CONTROL from control at the
welder to the remote control.

When in the DOWNHILL PIPE mode and when a

remote control is connected to the 6-Pin or 14-Pin
connector, the output control is used to set the max-
imum current range of the remote.

EXAMPLE: 

When the OUTPUT CONTROL on the

welder is set to 200 amps the current range on the
remote control will be 40-200 amps, rather than the
full 40-300 amps. Any current range that is less than
the full range provides finer current resolution for 
more fine tuning of the output.

In the CV-WIRE mode, if the feeder being used has a
voltage control when the wire feeder control cable is con-
nected to the 14-Pin Connector, the auto-sensing circuit
automatically makes OUTPUT CONTROL inactive and
the wire feeder voltage control active. Otherwise, the
OUTPUT CONTROL is used  to preset the voltage

14. WELDING TERMINALS SWITCH

In the WELD

TERMINALS

ON position, the output is elec-

trically hot all the time. In the REMOTELY

CONTROLLED

position, the output is controlled by a wire feeder or amp-
trol device, and is electrically off until a remote switch is
depressed.

15. WIRE

FEEDER

VOLTMETER

SWITCH:

Matches the polarity of the wire feeder voltmeter to the
polarity of the electrode.

16.  6 - PIN CONNECTOR

For attaching optional remote control equipment. Includes
auto-sensing remote control circuit.

17.  14 - PIN CONNECTOR

For attaching wire feeder control cables. Includes contac-
tor closure circuit, auto-sensing remote control circuit, and
120VAC and 42VAC power.

NOTE:

When a wire feeder with a built in welding voltage

control is connected to the 14-pin connector, do not con-
nect anything to the 6-pin connector.

VANTAGE® 500 DEUTZ

Содержание AIR VANTAGE 500

Страница 1: ...r machine www lincolnelectric com register Authorized Service and Distributor Locator www lincolnelectric com locator Need Help Call 1 888 935 3877 to talk to a Service Representative Hours of Operati...

Страница 2: ...KER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING Read and understand the following safety highlights For additional safety information it is strongly recommended that you purchase a copy...

Страница 3: ...r cooling 3 h Never simultaneously touch electrically hot parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welde...

Страница 4: ...to adjacent areas Avoid welding near hydraulic lines Have a fire extinguisher readily available 6 b Where compressed gases are to be used at the job site special precautions should be used to prevent...

Страница 5: ...opri s et non inflammables 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise paisse pa...

Страница 6: ...important when identifying the correct replacement parts On Line Product Registration Register your machine with Lincoln Electric either via fax or over the Internet For faxing Complete the form on t...

Страница 7: ...Premises Wiring A 7 Connection of Lincoln Electric Wire Feeders A 8 A 9 Operation Section B Safety Instructions B 1 General Description B 1 Recommended Applications B 1 Controls and Settings B 2 Engi...

Страница 8: ...ion D Safety Precautions D 1 Routine and Periodic Maintenance D 1 Engine Maintenance D 1 Air Filter D 1 D 2 Fuel Filters D 3 Cooling System D 3 Battery Handling D 3 Charging the Battery D 4 Nameplate...

Страница 9: ...lts at Rated Amps 100 500 Amps DC multi purpose 40 Volts 60 550 Amps DC multi purpose 36 volts 50 575 Amps DC multi purpose 35 volts PHYSICAL DIMENSIONS Height 2 Width Depth Weight 42 0 in 31 5 in 63...

Страница 10: ...side area DO NOT MOUNT OVER COMBUSTIBLE SURFACES Where there is a combustible surface directly under stationary or fixed electrical equipment that surface should be covered with a steel plate at least...

Страница 11: ...necessary For maximum output cur rent ratings derate welder voltage rating 2 volts for every 21 F 10 C above 104 F 40 C TOWING The recommended trailer for use with this equipment for road in plant an...

Страница 12: ...y To prevent EXPLOSION when INSTALLING A NEW BATTERY disconnect negative cable from old battery first and connect to new bat tery last WARNING PRE OPERATION ENGINE READ the engine operating and mainte...

Страница 13: ...welding terminals when in the WELD TERMINALS ON position or cold welding termi nals when in the REMOTELY CONTROLLED position WELDING OUTPUT CABLES With the engine off route the electrode and work cab...

Страница 14: ...welding voltage control is connected to the 14 pin connec tor do not connect anything to the 6 pin connec tor AUXILIARY POWER RECEPTACLES The auxiliary power capacity of the VANTAGE 500 DEUTZ is 12 0...

Страница 15: ...r cable of the desired length The 50 amp 120 240 VAC plug is available in the optional K802R plug kit 4 Plug this cable into the 50 Amp 120 240 Volt recep tacle on the VANTAGE 500 DEUTZ case front Fig...

Страница 16: ...the gun trigger is closed When the gun trigger is closed the wire will begin to feed and the welding process is started Shut the welder off For electrode Positive connect the electrode cable to the te...

Страница 17: ...ess Generally welding is best if the ARC CON TROL is set to SOFT for MIG and CRISP for INNERSHIELD You may however want to start in the middle and adjust as needed from there Set the IDLE switch to th...

Страница 18: ...lways operate the welder with the sliding door closed and the side panels in place as these pro vide maximum protection from moving parts and insure proper cooling air flow GENERAL DESCRIPTION The VAN...

Страница 19: ...this can cause dam age to the ring gear and or starter motor 3 HOUR METER The hour meter displays the total time that the engine has been running This meter is a useful indi cator for scheduling preve...

Страница 20: ...governor B In the Auto position the idler operates as follows a When switched from High to Auto or after starting the engine the engine will operate at full speed for approximately 12 seconds and then...

Страница 21: ...g stick welding to adjust for a soft or a more forceful digging arc Crisp Increasing the number from 10 Soft to 10 Crisp increas es the short circuit current which results in a more forceful digging a...

Страница 22: ...e AUXILIARY POWER RECEPTACLES section in the installation chapter for further information about these receptacles Also refer to the AUXILIARY POWER OPERATION section later in this chapter 22 GROUND ST...

Страница 23: ...ng to adjust for a soft or a more forceful digging arc Crisp Increasing the number from 10 Soft to 10 Crisp increases the short circuit current which results in a more forceful digging arc Typically a...

Страница 24: ...mm in Tungsten Tungsten Size 4 5 25 0 010 2 15 3 2 4 3 8 2 4 3 8 4 5 6 50 0 020 5 20 3 3 5 5 10 3 5 5 10 1 0 0 040 15 80 3 3 5 5 10 3 5 5 10 1 6 1 16 70 150 10 20 3 5 5 10 4 6 9 13 5 6 2 4 3 32 150 2...

Страница 25: ...t the IDLER control switch to the desired operating mode Full power is available regardless of the welding control settings if no weld ing current is being drawn The auxiliary power of the VANTAGE 500...

Страница 26: ...5 150 125 53 107 42 84 69 53 46 38 300 600 225 450 250 300 250 200 91 183 69 137 76 91 76 61 Maximum Allowable Cord Length in ft m for Conductor Size Conductor size is based on maximum 2 0 voltage dro...

Страница 27: ...ual voltage plug rated at 120 240V 50 amps single phase Pipe Thawing with an arc welder can cause fire explosion damage to electric wiring or to the arc welder if done improperly The use of an arc wel...

Страница 28: ...tactor K126 2 Magnum 350 Innershield Gun for LN 25 For self shielded wire with 15 ft 4 5m cable For 062 3 32 1 6 2 4mm wire KP653 3 32 Drive Roll and Guide Tube Kit for LN 25 For 068 3 32 1 8 2 4mm co...

Страница 29: ...to 3 seconds Repeat the above drainage procedure until diesel fuel is detected in the container WEEKLY Blow out the machine with low pressure air periodical ly In particularly dirty locations this ma...

Страница 30: ...itself and distribute the sealing pressure evenly To complete a tight seal apply pressure by hand at the outer rim of the filter not the flexible center Avoid pushing on the center of the urethane end...

Страница 31: ...battery last CONNECTING A BATTERY CHARGER Remove battery from welder by dis connecting negative cable first then positive cable and battery clamp When reinstalling connect negative cable last Keep wel...

Страница 32: ...uctions of the battery charger manu facturer for proper charger settings and charging time NAMEPLATES WARNING DECALS MAIN TENANCE Whenever routine maintenance is performed on this machine or at least...

Страница 33: ...IBLE CAUSE lists the obvious external possibilities that may contribute to the machine symptom Step 3 RECOMMENDED COURSE OF ACTION This column provides a course of action for the Possible Cause genera...

Страница 34: ...e Service Shop 1 Out of fuel 2 Fuel shut off valve is in the off position make sure the valve lever is in the open position lever in line with the Hose 3 Engine shut down solenoid not pulling in 4 On...

Страница 35: ...e fan belt may need tighten ing 1 Idler switch in HIGH idle position make sure switch is set to AUTO 2 External load on welder or auxil iary power 3 Mechanical problem in idler sole noid linkage 4 Fau...

Страница 36: ...auxiliary power 1 Faulty Peripheral PCB Idler Engine Protection PCB or Weld Control PCB 1 Broken lead in rotor circuit 2 Faulty field diode module 3 Faulty Weld Control PCB 4 Faulty rotor 1 Faulty re...

Страница 37: ...It may not be accurate for all machines covered by this manual The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels If the diagram is illegible write...

Страница 38: ...F 2 CONNECTION DIAGRAMS F 2 VANTAGE 500 DEUTZ...

Страница 39: ...ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE IF THIS VOLTAGE GOES OVER 140 VOLTS...

Страница 40: ...F 4 CONNECTION DIAGRAMS F 4 VANTAGE 500 DEUTZ...

Страница 41: ...F 5 CONNECTION DIAGRAMS F 5 VANTAGE 500 DEUTZ...

Страница 42: ...ASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE IF THIS VOLTAGE GOES OVER 140 VOLTS WIRE FEED...

Страница 43: ...F 7 CONNECTION DIAGRAMS F 7 VANTAGE 500 DEUTZ...

Страница 44: ...ION ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE AC WIRE FEEDER VOLTAGE WHICH CAN DAMAGE THE CONTROL CIRCU...

Страница 45: ...F 9 CONNECTION DIAGRAMS F 9 VANTAGE 500 DEUTZ...

Страница 46: ...F 10 CONNECTION DIAGRAMS F 10 VANTAGE 500 DEUTZ...

Страница 47: ...F 11 CONNECTION DIAGRAMS F 11 VANTAGE 500 DEUTZ...

Страница 48: ...F 12 CONNECTION DIAGRAMS F 12 VANTAGE 500 DEUTZ...

Страница 49: ...8962 5 A 28 99 19 63 6 53 24 97 6 55 23 69 50 38 54 44 14 63 37 30 45 38 6 56 42 00 50 81 15 50 31 50 45 67 BOTTOM VIEW OF WELDER BASE CENTER OF GRAVITY WITH OIL IN ENGINE AND EMPTY FUEL TANK 34 62 TR...

Страница 50: ...NOTES VANTAGE 500 DEUTZ...

Страница 51: ...electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese del trabajo y...

Страница 52: ...e Be und Entl ftung des Arbeitsplatzes Mantenha seu rosto da fuma a Use ventila o e exhaust o para remover fumo da zona respirat ria Turn power off before servicing Desconectar el cable de ali mentaci...

Страница 53: ...later than the following business day For Service outside the USA Email globalservice lincolnelectric com Cleveland Ohio 44117 1199 USA TEL 1 216 481 8100 FAX 1 216 486 1751 WEB SITE lincolnelectric...

Отзывы: