A-3

INSTALLATION   

VANTAGE® 500 DEUTZ

A-3

LIFTING

The VANTAGE® 500 DEUTZ lift bale should be used
to lift the machine. The VANTAGE® 500 DEUTZ is
shipped with the lift bale retracted. Before attempting
to lift the VANTAGE® 500 DEUTZ the lift bale must be
secured in a raised position. Secure the lift bale as fol-
lows:

a. Open the engine compartment door.

b. Locate the 2 access holes on the upper middle

region of compartment wall just below the lift
bale.

c. Use the lifting strap to raise the lift bale to the

full upright position. This will align the mount-
ing holes on the lift bale with the access holes.

d. Secure the lift bale with 2 thread forming

screws. The screws are provided in the
shipped loose parts bag.

• Lift only with equipment of ade-

quate lifting capacity.

• Be sure machine is stable when

lifting.

• Do not lift this machine using lift

bale if it is equipped with a heavy
accessory such as trailer or gas
cylinder.

FALLING 

• Do not lift machine if lift bale is 

EQUIPMENT can    damaged.

cause injury.      • Do not operate machine while

suspended from lift bale.

------------------------------------------------------------------------

HIGH ALTITUDE OPERATION

At higher altitudes, output derating may be necessary.
For maximum rating, derate the welder output 5% for
every 300 meters (984 ft.) above 1500 meters (4920
ft.). For output of 500A and below, derate the welder
output 5% for every 300 meters (984 ft.) above 2100
meters (6888 ft.).

Contact a Deutz Service Representative for any
engine adjustments that may be required.

HIGH TEMPERATURE OPERATION

At temperatures above 104°F (40°C), output voltage
derating may be necessary. For maximum output cur-
rent ratings, derate welder voltage rating 2 volts for
every 21°F (10°C) above 104°F (40°C).

TOWING

The recommended trailer for use with this equipment
for road, in-plant and yard towing by a vehicle 

(1)

is

Lincoln

ʼ

s K2636-1. If the user adapts a non-Lincoln

trailer, he must assume responsibility that the method
of attachment and usage does not result in a safety
hazard nor damage the welding equipment. Some of
the factors to be considered are as follows:

1. Design capacity of trailer vs. weight of Lincoln

equipment and likely additional attachments.

2. Proper support of, and attachment to, the base

of the welding equipment so that there will be
no undue stress to the trailer

ʼ

s framework.

3. Proper placement of the equipment on the

trailer to insure stability side to side and front
to back when being moved and when standing
by itself.

4. Typical conditions of use, such as travel

speed, roughness of surface on which the
trailer will be operated, and environmental
conditions.

5. Proper preventative maintenance of trailer.

6. Conformance with federal, state and local laws

(1)

.

(1) 

Consult applicable federal, state and local laws
regarding specific requirements for use on public
highways.

VEHICLE MOUNTING

Improperly mounted concentrated loads may
cause unstable vehicle handling and tires or other
components to fail.

• Only transport this Equipment on serviceable

vehicles which are rated and designed for such
loads.

• Distribute, balance and secure loads so vehicle

is stable under conditions of use.

• Do not exceed maximum rated loads for compo-

nents such as suspension, axles and tires.

• Mount equipment base to metal bed or frame of

vehicle.

• Follow vehicle manufacturer

ʼ

s instructions.

------------------------------------------------------------------------

WARNING

WARNING

Содержание AIR VANTAGE 500

Страница 1: ...r machine www lincolnelectric com register Authorized Service and Distributor Locator www lincolnelectric com locator Need Help Call 1 888 935 3877 to talk to a Service Representative Hours of Operati...

Страница 2: ...KER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING Read and understand the following safety highlights For additional safety information it is strongly recommended that you purchase a copy...

Страница 3: ...r cooling 3 h Never simultaneously touch electrically hot parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welde...

Страница 4: ...to adjacent areas Avoid welding near hydraulic lines Have a fire extinguisher readily available 6 b Where compressed gases are to be used at the job site special precautions should be used to prevent...

Страница 5: ...opri s et non inflammables 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise paisse pa...

Страница 6: ...important when identifying the correct replacement parts On Line Product Registration Register your machine with Lincoln Electric either via fax or over the Internet For faxing Complete the form on t...

Страница 7: ...Premises Wiring A 7 Connection of Lincoln Electric Wire Feeders A 8 A 9 Operation Section B Safety Instructions B 1 General Description B 1 Recommended Applications B 1 Controls and Settings B 2 Engi...

Страница 8: ...ion D Safety Precautions D 1 Routine and Periodic Maintenance D 1 Engine Maintenance D 1 Air Filter D 1 D 2 Fuel Filters D 3 Cooling System D 3 Battery Handling D 3 Charging the Battery D 4 Nameplate...

Страница 9: ...lts at Rated Amps 100 500 Amps DC multi purpose 40 Volts 60 550 Amps DC multi purpose 36 volts 50 575 Amps DC multi purpose 35 volts PHYSICAL DIMENSIONS Height 2 Width Depth Weight 42 0 in 31 5 in 63...

Страница 10: ...side area DO NOT MOUNT OVER COMBUSTIBLE SURFACES Where there is a combustible surface directly under stationary or fixed electrical equipment that surface should be covered with a steel plate at least...

Страница 11: ...necessary For maximum output cur rent ratings derate welder voltage rating 2 volts for every 21 F 10 C above 104 F 40 C TOWING The recommended trailer for use with this equipment for road in plant an...

Страница 12: ...y To prevent EXPLOSION when INSTALLING A NEW BATTERY disconnect negative cable from old battery first and connect to new bat tery last WARNING PRE OPERATION ENGINE READ the engine operating and mainte...

Страница 13: ...welding terminals when in the WELD TERMINALS ON position or cold welding termi nals when in the REMOTELY CONTROLLED position WELDING OUTPUT CABLES With the engine off route the electrode and work cab...

Страница 14: ...welding voltage control is connected to the 14 pin connec tor do not connect anything to the 6 pin connec tor AUXILIARY POWER RECEPTACLES The auxiliary power capacity of the VANTAGE 500 DEUTZ is 12 0...

Страница 15: ...r cable of the desired length The 50 amp 120 240 VAC plug is available in the optional K802R plug kit 4 Plug this cable into the 50 Amp 120 240 Volt recep tacle on the VANTAGE 500 DEUTZ case front Fig...

Страница 16: ...the gun trigger is closed When the gun trigger is closed the wire will begin to feed and the welding process is started Shut the welder off For electrode Positive connect the electrode cable to the te...

Страница 17: ...ess Generally welding is best if the ARC CON TROL is set to SOFT for MIG and CRISP for INNERSHIELD You may however want to start in the middle and adjust as needed from there Set the IDLE switch to th...

Страница 18: ...lways operate the welder with the sliding door closed and the side panels in place as these pro vide maximum protection from moving parts and insure proper cooling air flow GENERAL DESCRIPTION The VAN...

Страница 19: ...this can cause dam age to the ring gear and or starter motor 3 HOUR METER The hour meter displays the total time that the engine has been running This meter is a useful indi cator for scheduling preve...

Страница 20: ...governor B In the Auto position the idler operates as follows a When switched from High to Auto or after starting the engine the engine will operate at full speed for approximately 12 seconds and then...

Страница 21: ...g stick welding to adjust for a soft or a more forceful digging arc Crisp Increasing the number from 10 Soft to 10 Crisp increas es the short circuit current which results in a more forceful digging a...

Страница 22: ...e AUXILIARY POWER RECEPTACLES section in the installation chapter for further information about these receptacles Also refer to the AUXILIARY POWER OPERATION section later in this chapter 22 GROUND ST...

Страница 23: ...ng to adjust for a soft or a more forceful digging arc Crisp Increasing the number from 10 Soft to 10 Crisp increases the short circuit current which results in a more forceful digging arc Typically a...

Страница 24: ...mm in Tungsten Tungsten Size 4 5 25 0 010 2 15 3 2 4 3 8 2 4 3 8 4 5 6 50 0 020 5 20 3 3 5 5 10 3 5 5 10 1 0 0 040 15 80 3 3 5 5 10 3 5 5 10 1 6 1 16 70 150 10 20 3 5 5 10 4 6 9 13 5 6 2 4 3 32 150 2...

Страница 25: ...t the IDLER control switch to the desired operating mode Full power is available regardless of the welding control settings if no weld ing current is being drawn The auxiliary power of the VANTAGE 500...

Страница 26: ...5 150 125 53 107 42 84 69 53 46 38 300 600 225 450 250 300 250 200 91 183 69 137 76 91 76 61 Maximum Allowable Cord Length in ft m for Conductor Size Conductor size is based on maximum 2 0 voltage dro...

Страница 27: ...ual voltage plug rated at 120 240V 50 amps single phase Pipe Thawing with an arc welder can cause fire explosion damage to electric wiring or to the arc welder if done improperly The use of an arc wel...

Страница 28: ...tactor K126 2 Magnum 350 Innershield Gun for LN 25 For self shielded wire with 15 ft 4 5m cable For 062 3 32 1 6 2 4mm wire KP653 3 32 Drive Roll and Guide Tube Kit for LN 25 For 068 3 32 1 8 2 4mm co...

Страница 29: ...to 3 seconds Repeat the above drainage procedure until diesel fuel is detected in the container WEEKLY Blow out the machine with low pressure air periodical ly In particularly dirty locations this ma...

Страница 30: ...itself and distribute the sealing pressure evenly To complete a tight seal apply pressure by hand at the outer rim of the filter not the flexible center Avoid pushing on the center of the urethane end...

Страница 31: ...battery last CONNECTING A BATTERY CHARGER Remove battery from welder by dis connecting negative cable first then positive cable and battery clamp When reinstalling connect negative cable last Keep wel...

Страница 32: ...uctions of the battery charger manu facturer for proper charger settings and charging time NAMEPLATES WARNING DECALS MAIN TENANCE Whenever routine maintenance is performed on this machine or at least...

Страница 33: ...IBLE CAUSE lists the obvious external possibilities that may contribute to the machine symptom Step 3 RECOMMENDED COURSE OF ACTION This column provides a course of action for the Possible Cause genera...

Страница 34: ...e Service Shop 1 Out of fuel 2 Fuel shut off valve is in the off position make sure the valve lever is in the open position lever in line with the Hose 3 Engine shut down solenoid not pulling in 4 On...

Страница 35: ...e fan belt may need tighten ing 1 Idler switch in HIGH idle position make sure switch is set to AUTO 2 External load on welder or auxil iary power 3 Mechanical problem in idler sole noid linkage 4 Fau...

Страница 36: ...auxiliary power 1 Faulty Peripheral PCB Idler Engine Protection PCB or Weld Control PCB 1 Broken lead in rotor circuit 2 Faulty field diode module 3 Faulty Weld Control PCB 4 Faulty rotor 1 Faulty re...

Страница 37: ...It may not be accurate for all machines covered by this manual The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels If the diagram is illegible write...

Страница 38: ...F 2 CONNECTION DIAGRAMS F 2 VANTAGE 500 DEUTZ...

Страница 39: ...ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE IF THIS VOLTAGE GOES OVER 140 VOLTS...

Страница 40: ...F 4 CONNECTION DIAGRAMS F 4 VANTAGE 500 DEUTZ...

Страница 41: ...F 5 CONNECTION DIAGRAMS F 5 VANTAGE 500 DEUTZ...

Страница 42: ...ASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE IF THIS VOLTAGE GOES OVER 140 VOLTS WIRE FEED...

Страница 43: ...F 7 CONNECTION DIAGRAMS F 7 VANTAGE 500 DEUTZ...

Страница 44: ...ION ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE AC WIRE FEEDER VOLTAGE WHICH CAN DAMAGE THE CONTROL CIRCU...

Страница 45: ...F 9 CONNECTION DIAGRAMS F 9 VANTAGE 500 DEUTZ...

Страница 46: ...F 10 CONNECTION DIAGRAMS F 10 VANTAGE 500 DEUTZ...

Страница 47: ...F 11 CONNECTION DIAGRAMS F 11 VANTAGE 500 DEUTZ...

Страница 48: ...F 12 CONNECTION DIAGRAMS F 12 VANTAGE 500 DEUTZ...

Страница 49: ...8962 5 A 28 99 19 63 6 53 24 97 6 55 23 69 50 38 54 44 14 63 37 30 45 38 6 56 42 00 50 81 15 50 31 50 45 67 BOTTOM VIEW OF WELDER BASE CENTER OF GRAVITY WITH OIL IN ENGINE AND EMPTY FUEL TANK 34 62 TR...

Страница 50: ...NOTES VANTAGE 500 DEUTZ...

Страница 51: ...electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese del trabajo y...

Страница 52: ...e Be und Entl ftung des Arbeitsplatzes Mantenha seu rosto da fuma a Use ventila o e exhaust o para remover fumo da zona respirat ria Turn power off before servicing Desconectar el cable de ali mentaci...

Страница 53: ...later than the following business day For Service outside the USA Email globalservice lincolnelectric com Cleveland Ohio 44117 1199 USA TEL 1 216 481 8100 FAX 1 216 486 1751 WEB SITE lincolnelectric...

Отзывы: