Note: Ensure that the device load balancing network configuration is the same for all devices, otherwise
communication may fail and the load balancing function will not work normally.
Power grid side smart meter: Configure the address of power grid side smart meter (address is in red column),
and the address of electricity meter is 2 by default.
Maximum current that can be set by user: the maximum allowable current of the current system
Three-phase current imbalance: After opening, adjust the three phase currents to make them balance when
conditions permit, make the imbalance rate is less than 15%.
12.4 Networking of Chargers
12.4.1 2 Chargers Networking (Ethernet connection)
When conduct networking of 2 chargers using Ethernet cables, you need to turn on the load balancing
function on APP for both of them, Set the master charger and slave charger modes (1 master and 1 slave), and
in the load balancing interface, set the "Networking Configuration " as Ethernet. Two chargers need to be set
with different IP addresses in the same network segment, and then connect the two chargers directly with a