Pilot burner will not light or stay lit
Main burner will not light
FAULT FINDING (cont.)
Are the thermocouple/Interrupter
connections secure.
Check supply.
Yes.
Is there gas at the pilot when
holding control knob in the
pilot position.
No.
Tighten connection.
No
Yes.
Very little.
Check overtemperature
stat for open circuit.
If all of the above are OK the
control valve may be faulty.
Check pilot jet for
blockage and clean where
necessary.
Check supply.
Check thermocouple
voltage (minium 15mV).
Is the gas control set to the on position.
No
Yes.
Check output (200-400mV) from
thermopile while the pilot is in
operation.
If reading is lower replace
thermopile.
No.
Set to on position and retry.
No
Yes.
Yes.
Has the limit stat
operated.
Replace thermostat
and retry.
Is there continuity
through thermostat.
Re-set limit stat and
retry
Are the
thermopile/thermocouple
connections correct and
tight.
Correct and retry.
No.
Yes.
Is the pilot flame
impinging on the
thermopile.
Yes.
No.
Rectify and retry.