background image

Page 9 of 32

Repairs

In order to avoid the risk of malfunction, all DESKLINE

®

 repairs must only be carried out by authorised LINAK service centres or 

repairers, as special tools must be used and special gaskets must be fitted. Products under warranty must also be returned to 
authorised LINAK service centres. 
Further information on DESKLINE warranty can be found on the LINAK website 

www.linak.com/warranty. 

Warning!

If any of the DESKLINE

®

 products are opened, there will be a risk of subsequent malfunction.

Warning!

The DESKLINE

®

 systems do not withstand cutting oil.

Manufacturer’s declaration

 

 

 

 

 

DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY

 

 

 

LINAK A/S 

Smedevænget 8 

DK - 6430 Nordborg 

 

 

Herewith declares that LINAK DESKLINE

®

 products as characterized by the following models and types: 

 

Control Boxes  

CBD6S 

Linear Actuators 

DB5, DB6, DB14, LA23, LA31 

Lifting Columns 

DL1A, DL2, DL4S, DL5, DL5IC, DL6, DL6IC, DL7, DL8, DL8IC, DL9, DL9IC,  

 

DL10, DL10IC, DL11, DL11IC, DL12, DL14, DL15, DL16, DL16IC, DL17,  

 

DL19, DL19IC, BASE1 

 

Desk Panels  

DPA, DPB, DPH, DPF, DPG, DPT, DP, DP1CS 

 

RF Controls  

HB10RF, HB20RF, RFRL 

 

Accessories  

BA001, BLE2LIN, DS1, DF2, Kick & Click, SLS, SMPS001, SMPS002, SMPS006 

 

comply with the following parts of the Machinery Directive 2006/42/EC, ANNEX I, 

Essential health and 

safety requirements relating to the design and construction of machinery

 

1.5.1 Electricity supply

 

 

 

The relevant technical documentation is compiled in accordance with part B of Annex VII and that this 

documentation or part hereof will be transmitted by post or electronically to a reasoned request by the 

national authorities. 

 

This partly completed machinery must not be put into service until the final machinery into which 

it is to be incorporated has been declared in conformity with the provisions of the Machinery 

Directive 2006/42/EC where appropriate.

 

 

 

 

Nordborg,  2019-05-27 

 

 

 

 

 

LINAK A/S 

 

 

John Kling, B.Sc.E.E. 

 

 

Certification and Regulatory Affairs 

 

 

Authorized to compile the relevant technical documentation 

 

 

 

 

 

Original Declaration 

Содержание DESKLINE DL15 IC

Страница 1: ...Page 1 of 32 LINAK COM DESKLINE DL5 IC DL6 IC DL15 IC and DL16 IC system User manual ...

Страница 2: ...ity 10 Misc on the DESKLINE DL5 IC DL6 IC DL15 IC DL16 IC system 12 Warranty 12 Maintenance 12 ETL marking 13 Description of the DESKLINE DL5 IC DL6 IC DL15 IC DL16 IC system 14 Installation 15 Mounting guidelines for the DL5 IC DL6 IC DL15 IC DL16 IC system 15 Mounting guidelines for the DL5 IC DL6 IC DL15 IC DL16 IC foot part 16 Mounting the feet 17 Mounting a crossbar 18 Mounting the tabletop 1...

Страница 3: ...uality testing Should you nevertheless experience problems with your LINAK product system you are always welcome to contact your local contact LINAK subsidiaries and some distributors situated all over the world have authorised service centres which are always ready to help you LINAK provides a limited warranty on its products This warranty is however subject to correct use in accordance with the ...

Страница 4: ... for the following products See the first 3 5 characters on the label Columns 2 lifting columns DL5 IC standard DL5 IC PLUSTM DL6 IC standard DL6 IC PLUSTM DL15 IC DL16 IC Power supply SMPS001 SMPS002 or SMPS006 Controls DPA DPB DPH DP1K DPF1K DPG1K ...

Страница 5: ... or one of its components It is important for everyone who is to connect install or use the systems to have the necessary information and access to this User Manual Follow the instructions for mounting there is a risk of injury if these instructions are not followed The appliance is not intended for use by young children or infirm persons without supervision If there is visible damage to the produ...

Страница 6: ...y issues The builder of the equipment shall ensure that the use of the component complies with relevant standards like the Machine Directive Care must be taken to avoid squeezing of cables as it can cause movement of the system The SMPS001 SMPS002 SMPS006 must not be packed in heat insulating material but must be placed so that it can emit waste heat to the surroundings There are no ventilation ho...

Страница 7: ...connection The individual parts must be connected before connecting the control box to the mains See the User Manual for LINAK actuators if necessary During operation If the column makes unusual noise or smells switch off the mains voltage immediately Take care that the cables are not damaged Unplug the mains cable on mobile equipment before moving it The products must only be used in an environme...

Страница 8: ...ns with reduced physical sensory or mental abilities must not use the product products unless they are under surveillance or they have been thoroughly instructed in the use of the apparatus by a person who is responsible for the safety of these persons Moreover children must be under surveillance to ensure that they do not play with the product It is the operator s responsibility to ensure that th...

Страница 9: ...5IC DL6 DL6IC DL7 DL8 DL8IC DL9 DL9IC DL10 DL10IC DL11 DL11IC DL12 DL14 DL15 DL16 DL16IC DL17 DL19 DL19IC BASE1 Desk Panels DPA DPB DPH DPF DPG DPT DP DP1CS RF Controls HB10RF HB20RF RFRL Accessories BA001 BLE2LIN DS1 DF2 Kick Click SLS SMPS001 SMPS002 SMPS006 comply with the following parts of the Machinery Directive 2006 42 EC ANNEX I Essential health and safety requirements relating to the desi...

Страница 10: ... 65 EU according to the standard EN 50581 2012 And RF Control RFRL00x HB1xRF3000 HB2xRFx000 RFT000 complies with the Radio Equipment Directive 2014 53 EU EN 300220 2 2006 EN 61000 6 1 2007 EN 61000 6 3 2007 EN 60335 1 2012 EN 62311 2008 complies with RoHS2 Directive 2011 65 EU according to the standard EN 50581 2012 Nordborg 2017 08 25 LINAK A S John Kling B Sc E E Certification and Regulatory Aff...

Страница 11: ...omplies with the EMC Directive 2014 30 EU according to following standards EN 61000 6 1 2007 EN 61000 6 3 2007 complies with Low Voltage Directive 2014 35 EU according to the standard EN 61558 2 16 2009 complies with RoHS2 Directive 2011 65 EU according to the standard EN 50581 2012 This declaration of conformity is issued under the sole responsibility of the manufacturer ...

Страница 12: ...ectrical appliance is one which has been designed in such a way that it does not require a safety electric earth connection US ground The basic requirement is that no single failure can result in dangerous voltage becoming exposed so that it might cause an electric shock and that this is achieved without relying on an earthed metal casing This is usually achieved at least in part by having two lay...

Страница 13: ...o CSA Std C22 2 No 68 09 ETL Recognized Component mark for Canada and United States C N 4009507 Conforms to UL962 Cert to CSA Std C22 2 No 68 09 ETL Recognized Component mark for Canada and United States ETL marking Due to space limitations the complete ETL marking demands are not represented on the marking plates The full ETL Recognized Component markings are shown here C N 120690 Conforms to UL9...

Страница 14: ...data sheets must NOT be exceeded as this will result in a superheating of the motor the brake and the spindle nut Exceeding the duty cycle will result in a dramatic reduction of the life of the system A DL IC system typically consists of 2 lifting columns DL5 IC standard DL5 IC PLUSTM DL6 IC standard DL6 IC PLUSTM DL15 IC DL16 IC Power supply SMPS001 SMPS002 or SMPS006 Desk panel DPA DPB DPH DP1K ...

Страница 15: ...oughly torque max 7 5 Nm Always use six M6 screws for mounting the motor housing on the top frame Mounting screws must not go further than max 10 mm into the motor housing Sufficient stability of the desk is only obtained if all six M6 screws are used for mounting the motor housing on the top frame Tests with fixing the motor housing using only four M6 screws have proved that the torsional stabili...

Страница 16: ... two M8 screws with the following specifications Quality Min grade 8 8 Length Min 10 mm plus foot thickness Max 16 mm plus foot thickness for M6 Max 14 mm plus foot thickness for M8 2 Fasten screws thoroughly torque max 10 Nm The holes in the foot must be sufficiently larger than ø6 ø8 to ensure space for the screw heads to be screwed fully into the foot DL5 IC DL6 IC bottom plate Column bottom mo...

Страница 17: ...sing four M6 screws with the following specifications Quality Min grade 8 8 Length Min 10 mm plus foot thickness Max 20 mm plus foot thickness 2 Fasten screws thoroughly torque max 10 Nm The holes in the foot must be sufficiently larger than ø6 to ensure space for the screw heads to be screwed fully into the foot DL15 IC DL16 IC bottom plate ...

Страница 18: ...distance and type of monitor If this is the case the problem may be solved by placing an iron plate tube or another magnetic material somewhat larger than the motor housing between the motor and the tabletop Mounting the tabletop The sound from the lifting column spreads as vibrations to the tabletop which amplifies the sound This can however be reduced 1 Place vibration shock absorbing material b...

Страница 19: ...ed Motor cable SMPS cable Desk panel example 1 Connect the master and follower columns using the motor cable 2 Mount the desk panel onto the desk and connect it to the master column 3 Connect the SMPS to the master column and to the mains ...

Страница 20: ...tributor or subsidiary Accessories Please contact your nearest LINAK contact distributor or subsidiary Warning By unauthorised opening of the system there is a risk that it may malfunction at a later date Spare parts Please contact your nearest LINAK contact for information on spare parts ...

Страница 21: ...stion Electronics scrap By now almost all our casted plastic parts are supplied with an interior code for plastic type and fibre content if any Main groups of disposal Product main groups Metal Scrap Cable scrap Electronics scrap Plastic recycling or combustin Comments DLXX IC X X X X DPXX X X X SMPS X X Disposal of batteries Details regarding safe disposal of used and leaking batteries Batteries ...

Страница 22: ...bel for DL5 IC Master Label for DL5 IC PLUSTM Master Label for DL6 IC Master Label for DL6 IC PLUSTM Master Label for DL5 IC PLUSTM Follower Label for DL6 IC PLUSTM Follower Label for DL5 IC Follower Label for DL6 IC Follower ...

Страница 23: ...Page 23 of 32 Label for DL15 Master Label for DL15 Follower Label for DL16 Master Label for DL16 Follower Label for SMPS001 Label for SMPS002 Label for SMPS006 ...

Страница 24: ...5 built in length stroke length and outer profile length mm Version Combination code B Built in length mm S Stroke length mm O Outer profile length mm EU DL5xxxxxx645500 645 500 590 DL5 IC DL5 IC motor housing and profile dimensions mm ...

Страница 25: ...nsions in mm Combination code Bench left Bench right DL5xxLxxSxxxxxx X DL5xxRxxMxxxxxx X DL5 IC Bracket options Socket Socket combination Combination code Type DL5xxxxxMxxxxxx IC Master DL5xxxxxSxxxxxx IC Follower IC Master IC Follower ...

Страница 26: ...ength and outer profile length mm Version Combination code B Built in length mm S Stroke length mm O Outer profile length mm EU DL6xxxxxx650560 560 650 498 BIFMA DL6xxxxxx665518 518 665 456 DL6 IC DL6 IC motor housing and profile dimensions mm ...

Страница 27: ...nsions in mm Combination code Bench left Bench right DL6xxLxxSxxxxxx X DL6xxRxxMxxxxxx X DL6 IC Bracket options Socket Socket combination Combination code Type DL6xxxxxMxxxxxx IC Master DL6xxxxxSxxxxxx IC Follower IC Master IC Follower ...

Страница 28: ...Page 28 of 32 Standard PLUSTM Profile designs ...

Страница 29: ...Page 29 of 32 DL15 IC M Master DL15 IC S Follower ...

Страница 30: ...Page 30 of 32 DL16 IC M Master DL16 IC S Follower ...

Страница 31: ...Page 31 of 32 SMPS002 SMPS001 ...

Страница 32: ...ns under which LINAK products will be installed used and operated as each individual application is unique The suitability and functionality of the LINAK product and its performance under varying conditions application vibration load humidity temperature frequency etc can only be verified by testing and shall ultimately be the responsibility of the LINAK customer using any LINAK product LINAK shal...

Страница 33: ...ALIA S r l Phone 39 02 48 46 33 66 Fax 39 02 48 46 82 52 www linak it Japan LINAK K K Phone 81 45 533 0802 Fax 81 45 533 0803 www linak jp Malaysia LINAK Actuators Sdn Bhd Phone 60 4 210 6500 Fax 60 4 226 8901 www linak my Netherlands LINAK Actuator Systems B V Phone 31 76 5 42 44 40 www linak nl New Zealand LINAK New Zealand Ltd Phone 64 9580 2071 Fax 64 9580 2072 www linak com au Norway LINAK No...

Отзывы: