Installation
Ensure that the CBD6S and/or T-splitter are fixed securely to the tabletop for optimal DS1 performance.
The DS1 reacts to angle changes from its original position. Thus, the DS1 mounting direction is
not
important.
If the DS1 is removed from the system or is no longer mounted correctly, the desk panel will show error
94 at the first activation. At the next activation, however, the desk will drive as intended.
System with Control Box CBD6S
1.
Plug DS1 into port A1 on CBD6S.
Ensure that the cable mounted in port A2 is fastened thoroughly
and
cannot
touch the DS1 while the desk is running.
System with IC columns
1.
Mount T-splitter on tabletop using two M4.5 x 25 screws.
2. Plug DS1 into port on single-port side of T-splitter.
Always use the port on the single-port side of the T-splitter for the DS1 to ensure that the DS1 is not
undesirably triggered by movement of the serial cable or the cable for the desk panel.
The DS1 can be installed in any direction as tilting is detected in three planes.