Method of operation
The DS1 operates on the gyroscope principle detecting tilting of the desk. If the desk starts tilting while driving
up or down, the DS1 reacts
to
an angle change. If the angle change is larger than 0.7° per second, the DS1
immediately stops the desk and drives it in the opposite direction. This return drive automatically continues for
maximum 4 seconds (approximately 40 mm). The return drive is independent of the user’s interaction with the
control but will never run farther than the run causing the collision.
The original angle of the DS1 is updated each time the desk is operated after the control has been in sleep
mode (approximately 10 seconds after operation). The gyroscope will allow a slight change in angle (below 0.7°
per second), for example if a heavy load is placed on one side of the desk forcing the desk to lean slightly, but
if the absolute tilt exceeds 10° compared to the original angle of the DS1, the desk will stop and drive in the
opposite direction.
The desk construction may influence the DS1 function:
• On a desk with a very fixed frame, the force required for the desk to tilt is bigger, thus collision
(e.g. with soft objects) may not cause the desk to tilt at all.
• On a desk with a very loose frame, the tabletop may tilt easily and cause undesired triggering,
even when no collision is actually happening.
The Anti-Collision function is not activated if the collision happens:
•
during the initialisation procedure
•
within the first 0.8 seconds of desk panel activation (ramp-up time)
The DS1 is very sensitive and may cause false triggering if not mounted correctly. To achieve the best possible
performance of the DS1, install the DS1 on the tabletop via either a CBD6S or a T-splitter.
In case of false triggering, please check this list:
• Make sure that the control box or T-splitter is fixed securely to the table.
• Make sure the cables connected next to the DS1 in the control box or T-splitter are fastened thoroughly
and
cannot
touch the DS1.
• If the desk is unstable, it may result in false triggering. Make sure the desk is stable and cannot tilt back
and forth by adjusting the screws under the feet correctly.
• Make sure that no objects such as cables or furniture under the desk can stop the driving up or down of the desk.
• If none of the above helps:
- unplug the DS1
- wait 10 seconds
- plug the DS1 back in
Содержание Desk Sensor1
Страница 1: ...Page 1 of 20 LINAK COM DESKLINE Desk SensorTM 1 User manual...
Страница 11: ...Page 11 of 20 Valid for This User manual is valid for the following product Desk SensorTM 1...
Страница 16: ...Page 16 of 20 DRAWING APPENDIX Desk SensorTM 1 T splitter 10 8 60 1 14 6...
Страница 17: ...Page 17 of 20 Label Desk Sensor 1 T splitter...
Страница 19: ...Page 19 of 20...