Anti-Collision

TM

This function is an option for the standard CBD6S (SMPS) control box.

Enabling the anti-collision

To enable the anti-collision function a little plug called a dongle must be mounted in one of the 2 control ports. The function is 
only active when the dongle is mounted. – If you remove the dongle again you disable the function.

Method of operation

When the lifting columns are running the CBD6S (SMPS) monitors the current consumption on each channel using a special 
algorithm. If the current consumption on one channel is increased more than a predefined slope, a collision is assumed, and 
all channels are stopped immediately, and all lifting columns will start to run in the opposite direction (approx. 50 mm). This 
return drive is done automatically and continues with or without any control key pressed (for max. 2.5 sec.).

The anti-collision sensitivity is different in upward and downward direction. In downward direction the software is less sensitive 
and requires a higher load to activate the function. Thus, the Anti-Collision™ is not recommended for applications with light-
weight desks.

The Anti-Collision function is not activated if the collision happens: 

•  during the initialisation procedure 
•  within the first second of desk panel activation (ramp-up time) or within the first second after the desk panel 
  has been released (ramp-down time) 
•  in downward direction and the load at the point of collision is too low 
•  over too long time, e.g., if the collision is with a soft object

Содержание DB14

Страница 1: ...Page 1 of 42 LINAK COM DESKLINE DL12 DL14 DB14 and DL17 system with CBD6S User manual...

Страница 2: ...of double insulated products 12 ETL markering 13 Description of the DESKLINE system 14 Installation of the DL14 system 15 Mounting the top 15 Mounting the foot 16 Installation of the DL12 system 18 M...

Страница 3: ...ality testing Should you nevertheless experience problems with your LINAK product system you are always welcome to contact your local contact LINAK subsidiaries and some distributors situated all over...

Страница 4: ...he label Columns DL12 DL14 DL17 Built in actuators DB14 Control boxes CBD6S 200 W CBD6S 300 W Controls DPF1M DPG1M DPG1B if memory function is required DP1CS DPT DPF1C DPG1C if memory function and dis...

Страница 5: ...e NOTE symbol may result in serious damage to the system or one of its components It is important for everyone who is to connect install or use the systems to have the necessary information and access...

Страница 6: ...dividual parts must be connected before connecting the control box to the mains See the User Manual for LINAK actuators if necessary During operation If the control box makes unusual noises or smells...

Страница 7: ...s with reduced physical sensory or mental abilities must not use the product products unless they are under surveillance or they have been thoroughly instructed in the use of the apparatus by a person...

Страница 8: ...l gaskets must be fitted Products under warranty must also be returned to authorised LINAK service centres Further information on the LINAK warranty can be found on the LINAK website www linak com war...

Страница 9: ...a0b00470645 where a can be 0 or R b can be A B C or D DL2 DL2abCcdefffggg where a can be 3 6 or 7 b can be from 0 to 3 c can be A or B d can be 0 F or G e can be from 0 to 7 fff can be from 300 to 500...

Страница 10: ...from 300 to 500 ggg can be from 445 to 655 BASELIFT BASE1000A0F100100 Desk Panel s DPA DPB DPH DPF1K DPF1M DPF2K DPF3K DPF1C DPF1D DPF1U DPF1W DPF4T DPG1K DPG1M DPG1B DPG1C DPT DP1V01 DP1CS DP1K DP1U...

Страница 11: ...ugs and check for correct functioning as well as fixing points Cleaning the desk panel Clean your desk panel with a soft damp cloth Universal cleaning detergents may be used For disinfection of the de...

Страница 12: ...usually achieved at least in part by having two layers of insulating material surrounding live parts or by using reinforced insulation There is no earthing grounding means provided on the product and...

Страница 13: ...CSA Std C22 2 No 68 09 ETL Recognized Component mark for Canada and United States C N 4009507 Conforms to UL962 Cert to CSA Std C22 2 No 68 09 ETL Recognized Component mark for Canada and United Stat...

Страница 14: ...oad followed by 9 minutes pause stated in the data sheets must NOT be exceeded as this will result in a superheating of the motor and the control box Exceeding the duty cycle will result in a dramatic...

Страница 15: ...readed holes for mounting onto the top frame 1 Mount the column top on the top frame using four M6 screws or two M8 screws with the following specifications Quality Min grade 8 8 Length Min 9 mm plus...

Страница 16: ...d holes 1 Mount the column bottom on the desk feet using four M6 screws with the following specifications Quality Min grade 8 8 Length Min 10 mm plus desk feet thickness Max 16 mm plus desk feet thick...

Страница 17: ...esk Mounting the tabletop The sound from the lifting column spreads as vibrations to the tabletop which amplifies the sound This can however be reduced 1 Place vibration shock absorbing material betwe...

Страница 18: ...he top The DL12 top plate is supplied with four M6 threaded holes for mounting onto the top frame 1 Mount the column top on the top frame using four M6 screws with the following specifications Quality...

Страница 19: ...ications Quality Min grade 8 8 Length Min 10 mm plus top frame thickness Max 14 mm plus top frame thickness 2 Fasten the screws thoroughly torque max 10 Nm Mounting the foot The DL17 bottom plate is s...

Страница 20: ...ecommend orienting the column so that the cable is pointing towards the centre of the desk As the desktop amplifies the sound we advise you to place a vibration shock absorbing material between the de...

Страница 21: ...SKLINE system Mounting the top The top of the motor is supplied with holes for the self tapping special screws On the top of the motor there is the special rubber suspension which should always be use...

Страница 22: ...groove and spline Mounting the middle tube The DB14 gives the possibility of synchronous drive of the middle profile To make sure that the profiles are in the right place you have to ensure that both...

Страница 23: ...of 10 mm 8 to 10 mm can be used 5 Fasten the mounting screws max torque 1 Nm Notes If the control box is mounted in a top frame bar with the width of the motor housing it can be mounted with one screw...

Страница 24: ...using a clip observing the 30 mm minimum bending radius R Connecting the system 1 Connect the first DL DB to socket 1 next to port A2 on the control box using the 6 pin plug on the motor cable Channe...

Страница 25: ...e the button and press down again within 10 seconds The desk will run further in and then run approx 5 mm out again Only release the down button when the movement has stopped completely If the button...

Страница 26: ...otecting the desk from being damaged when driven into such objects This feature is called an anti collision system To a certain extent this feature also increases the personal safety but it does not c...

Страница 27: ...the system also increases the personal safety but it does not comply with legislation describing personal safety PIEZO allows the DL12 DL14 and DL17 columns to have the standard built in dimension an...

Страница 28: ...ly and all lifting columns will start to run in the opposite direction approx 50 mm This return drive is done automatically and continues with or without any control key pressed for max 2 5 sec The an...

Страница 29: ...ributor or subsidiary Accessories Please contact your nearest LINAK contract distributor or subsidiary Warning By unauthorised opening of the system there is a risk that it may malfunction at a later...

Страница 30: ...ow almost all our cast plastic parts are supplied with an interior code for plastic types and fibre contents if any Main groups of disposal Product main groups Metal scrap Cable scrap Electronics scra...

Страница 31: ...Page 31 of 42 Label for DL14 Label for DB14 Label for DL17 Label for DL12 Label for CBD6S 200 W SMPS Label for CBD6S 300 W SMPS up to 4 channels Labels...

Страница 32: ...Page 32 of 42 DRAWING APPENDIX DL12...

Страница 33: ...Page 33 of 42 DL12XL extended version Column top dimensions mm Bottom plate dimensions mm DL12XL dimensions mm...

Страница 34: ...Page 34 of 42 DL12 with motor housing DL12 with motor housing dimensions mm...

Страница 35: ...mm DL14 built in length stroke length and outer profile length mm Version Combination code S Stroke length mm B Built in length mm O Outer profile length mm Standard columns EU DL14xxxxxx660525 525 6...

Страница 36: ...Page 36 of 42 Combination code Std bracket DL14xx1xxxxxxxxx X Bracket options dimensions in mm Standard PLUS without trim ring PLUS with trim ring Profile designs...

Страница 37: ...Page 37 of 42 DL17 without bracket The bracket is not available with PLUS columns Standard bracket dimensions mm...

Страница 38: ...Page 38 of 42 DL17 with bench bracket Left column...

Страница 39: ...Page 39 of 42 DL17 with bench bracket Right column DB14 Drawing No DB14_NEW_MOTOR 45 12 4 48 12 73 12 73 Nominal length 508 3mm Minimum length retracted at max load 503 36 42 Drawing No DB14_NEW_MOTOR...

Страница 40: ...Page 40 of 42 CBD6S 200W SMPS CBD6S 300W SMPS up to 4 channels...

Страница 41: ...under which LINAK products will be installed used and operated as each individual application is unique The suitability and functionality of the LINAK product and its performance under varying condit...

Страница 42: ...011 4303 8989 8900 Fax 011 4032 0184 www novotecargentina com Colombia MEM Ltda Tel 57 1 334 7666 Fax 57 1 282 1684 www mem net co India Mechatronics Control Equipments India Pvt Ltd Tel 91 44 2855848...