Mounting guidelines for the DB14
For detailed information on how to mount the DB14, please contact DESKLINE Technical Support at LINAK A/S.
Please note: The screws and rubber washers for mounting the DB14 in profiles must be ordered separately,
please contact DESKLINE Technical Support at LINAK A/S.
Example of an assembled DESKLINE
®
system
Mounting the top
The top of the motor is supplied with holes for the self-tapping special screws.
On the top of the motor there is the special rubber suspension, which should always be used when the DB14 is mounted in
a column. The rubber suspension is grey; a grey rubber suspension means no PIEZO. The top flange onto which the motor is
mounted must be 4 mm thick ±0.1 mm, and the two mounting holes should be ø12 mm with a centre distance of 36 mm.
The
torque is 2 Nm ±0.1 Nm.
Special screws
Rubber washer
Rubber suspension
Motor