Figure 7
DP
DL/DB
Cable relief
Mains cable
DL/DB
Electric connection of the DB/DL system
The control box must only be connected to the voltage stated on the label.
It is important to ensure that the motor cables are fixed, but not tightened, near the control box
and
near the columns.
Fix the cable to the tabletop using a clip observing the
30 mm minimum bending radius (R).
Connecting the system
1. Connect the first DL/DB to socket 1 next to port A2 on the control box using the 6-pin plug on the motor cable.
Channel 1 is the channel closest to the control port.
2. Connect further DL/DB to sockets 2, 3 and 4 in sequence.
3. Connect the desk panel to control port A1 or control port A2.
4. Check that the voltage stated on the label corresponds to the mains power.
If not, do
not
plug in mains cable.
5. Plug in the mains cable.
6. Switch on the power.