LMS7002M Quick Starter Manual for EVB7 kit
66 |
P a g e
Version: 2.2
Last modified: 29/09/2014
TxTSP
7.17
The Tx_TSP tab controls the digital blocks of TxTSPA and TxTSPB modules.
Figure 42 GUI TxTSP tab
A picture of the tab is shown in Figure 42. A description of each function available in this tab is
shown below in Table 19.
Table 19 GUI TxTSP control description
Parameter
Description
Enable TxTSP
Enables TxTSP modules enable. Enabled by default.
CMIX_GAIN
CMIX gain control. Control range from -6 dB to +6d B. Step size 6 dB. Set to 0 dB by
default.
CMIX Spectrum control
Spectrum control of CMIX. By default set to downconvert.
Start BIST
Starts TxTSP built-in self-test. Keep it at 1 one at least three clock cycles.
Bypass
CMIX
Bypass CMIX module when selected.
GFIR3
Bypass GFIR3 module when selected.
GFIR1
Bypass GFIR1 module when selected.
Gain correction
Bypass Gain correction module when selected.
ISINC
Bypass ISINC module when selected.
GFIR2
Bypass GFIR2 module when selected.
DC Correction
Bypass DC correction module when selected.
Phase correction
Bypass Phase correction module when selected.
GFIR1
Length
Set GFIR parameter I. Control range from 0 to 7.
Clock Division Ration
Sets GFIR filter clock division ration. Control range from 0 to 255.
Coefficients
Sets/Load GFIR filters coefficients. By default all set to 0.
GFIR2
Length
Set GFIR parameter I. Control range from 0 to 7.