LMS7002M Quick Starter Manual for EVB7 kit
51 |
P a g e
Version: 2.2
Last modified: 29/09/2014
Input
stage
bias
current low band real
pole filter
This controls the operational amplifier's input stage bias current. Control range from 0 to 31.
Default is set to 12
Input
stage
bias
reference current of
high band low pass
filter
This controls the operational amplifiers input stage bias reference current of the high band
filter. Control range from 0 to 31. Default is set to 12.
Output stage bias
reference current of
high band low pass
filter
This controls the operational amplifiers output stage bias reference current of the high band
filter. Control range from 0 to 31. Default is set to 12.
Output stage bias
reference
for low
band ladder filter
This controls the operational amplifiers' output stages bias reference current of the low band
filter. Control range from 0 to 31. Default is set to 12.
Input
stage
bias
reference
for low
band ladder filter
This controls the operational amplifiers' input stages bias reference current of the low band
filter. Control range from 0 to 31. Default is set to 12.
Power down controls
LPFHTBB biquad
Enables LPFH filter when deselected. By default filter is powered down.
LPFIAMP front-end
current amp
Enables LPF current amplifier when deselected. By default current amplifier is enabled.
LPFLADTBB
low
pass ladder filter
Enables LPF ladder when deselected. By default current amplifier is enabled.
LPFS5TBB low pass
real-pole filter
Enables LPF real-pole filter when deselected. By default real-pole filter is enabled.
Turn
off
all
of
TBBTOP
Enables TBB blocks once selected. By default TBB blocks are enabled.
Enable direct control
of PDs and ENs
Enables direct control of PDs and ENs for TBB. Enabled when selected.
Resistor banks
Equivalent resistance
of biquad filter stage
Control LPFH bandwidth. Control range from 0 to 255. The higher number the higher
bandwidth. Default setting is 0.
Equivalent resistance
of low pass filter
ladder
Control LPFL bandwidth. Control range from 0 to 255. The higher number the higher
bandwidth. Default setting is 193.
Common
control
signal for all
A common control signal for all the capacitor banks of TBB filters. Control range from 0 to
31. Default register value set to 8.
Equivalent resistance
of real pole filter
stage
This controls the value of the equivalent resistance of the resistor banks of the real pole
filter stage. Control range from 0 to 255. Default register value set to 76.