27
Required Components
• Aurora SE
• RGB LED fixture
• Voltmeter
Method
1. Power ON your Aurora SE system.
2. Turn the lights on all white to draw max power.
3. Measure the voltage between port 1 (+) and port 3 (-) on the female connector at
then end of the light run.
4. Ensure the measured voltage is greater than the thresholds listed above.
5. Remove the last section of lights if the voltage is too low.
6. Add a power Top-Up and reconnect lights.
7. Retest the end-of-line voltage to ensure it meets the threshold.
Approved Lamp Types
• Lamp type: LED 5050
• Lamp wattage: 1 W
• All RGB LED fixtures use LED 5050 as the lamp type.
Warning:
Please contact Limbic Media to use Aurora SE with fixtures other than those
listed in the following table.
Содержание Aurora SE
Страница 1: ...1 NOV 2019 v3 USER MANUAL For Software Version 1 9 0 ...
Страница 2: ...2 ...
Страница 24: ...24 Enclosure Measurements ...
Страница 25: ...25 Aurora SE Measurements ...
Страница 31: ...31 ...
Страница 32: ...32 limbicmedia ca 2 740 Discovery Street Victoria BC V8T 1H2 778 430 5123 info limbicmedia ca ...