HOLD
Indoor Fixed Value
Fluorescent Light Fixed Value
User
Outdoor Fixed Value
: Convergence Operation is stopped when shifting to Hold mode, as the
color temperature is 2500K~9500K.
: Indoor Fixed Value mode should be set as color
temperature 3200K.
:
: Fluorescent Light Fixed Value mode should be
set as color temperature 4200K.
: User mode should be set as color temperature 4700K.
: Outdoor Fixed Value mode should be set as color
temperature 6300K.
LL (LINE-LOCK) / INT (INTERNAL SYNC.) SELECTION SWITCH
Selects the camera synchronization mode from internal sync. mode(INT) or
line-lock mode (LL).
LL
INT
: Set to line-lock mode. Make the vertical phase of the camera video signal
matched to the phase of AC power.
: Sets to internal 2:1 interlace.
14
When you use auto iris lens, do not set the level on the lens to too low, Color/Mono may
not change over automatically.
NOTE
AUTO IRIS LENS SELECTION SWITCH (DC/VS)
Switch for selecting the control signal for auto iris lens.
DC
VS
: For auto iris lenses controlled by DC (Direct drive) signals.
: For auto iris lenses controlled by Video signals.
13
Sync. mode is fixed to "INT" in DC12V input power.
NOTE
ATW
PUSH
: ATW is the Auto Trace White Balance mode that automatically aligns
the white balance, as the color temperature is 2500K~9500K.
: Push mode is performed at a faster operating speed than ATW without
and operation frame, as the color temperature is 2500K~9500K.
6