b. Prepare the individual conductors for clamping. After clamping the contacts, push them
into the proper holes in the accessory connector of this camera until they snap in place.
CAUTIONS : CONNECT THIS TO 24V AC CLASS 2 POWER SUPPLY ONLY.
Contact
UP
3. Video Out BNC Jack
Video Signal Output CVBS 1.0Vp-p 75
BNC
Recommended Data Cable: 5C2V
4. Alarm In/Out Connector
Each fast dome contains 6 alarm inputs and 1 alarm output.
Alarm Input Voltage: 5.6V max.
Alarm Output: 1A 24VDC
Recommended Data Cable: UL26 AWG 80°
300V
C
UL24 AWG 80°C 300V
6. Network Connector RJ45
LAN : 10/100Mbps
Recommended Data Cable : CAT5
Ω
Reset
NC
NO
COM.
GND
IN6
IN5
IN4
IN3
IN2
IN1
Alarm Out:
Alarm In:
(Pink)
(Brown)
(Gray)
(White)
(Black)
(Red)
(Green)
(Orange)
(Blue)
(Yellow)
(Violet)
Low Temperature Start-up
Camera may perform abnormally at low temperature. Hence, please operate low temperature
start-up procedure when the camera is off due to power outage or other issues and needs to be
restarted under -40°C to -5°C condition.
To connect the power cord for warming up the heater for an hour until the temperature
detector automatically turns on, then the system will run again.
Low temperature start-up procedure