AMM80 • SSI, BiSS, & RS-485
7.4 Data Field
Data Field DF is related to Control Field CF, for a correct Data ID see the “7.3.1
Control Field” section on page 45.
Data
ID
DF0
DF1
DF2
DF3
DF4
DF5
DF6
DF7
Data ID
0
ABS0
ABS1
ABS2
Data ID
1
ABM0 ABM1 ABM2
Data ID
2
ENID
Data ID
3
ABS0
ABS1
ABS2
ENID
ABM0 ABM1 ABM2
ALMC
Data ID
7
ABS0
ABS1
ABS2
Data ID
8
ABS0
ABS1
ABS2
Data ID
C
ABS0
ABS1
ABS2
Blank field means that no byte is transmitted.
Position is transmitted from LS byte to MS byte in binary output code.
High bits that are not used have fixed value = “0”.
ABS
: absolute value data within singleturn information, ABS0 is the low
byte, ABS2 is the high byte.
ABM
: multiturn data, ABM0 is the low byte, ABM2 is the high byte.
ENID : encoder ID, fixed value = 23h
ALMC : encoder error, see the ALMC table below
ALMC byte (the bit is high = “1” upon error occurrence):
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
BATT
MTERR
PSERR
Fixed to
“0”
Fixed to
“0”
STERR
BUSY
Fixed to
“0”
See the next “7.4.1 Encoder errors” section.