3. remove the spent battery;
4. install and connect the new battery;
5. switch the 5Vdc power supply on; the ERROR LED is on or blinks;
6. switch the 5Vdc power supply off;
7. switch the 5Vdc power supply on;
8. the ERROR LED is off;
9. the singleturn and multiturn positions are provided properly: the
singleturn position is exactly the same the encoder was in when you
stopped it; the multiturn position is different than before;
10. slowly turn the disk: both WARNING and ERROR LEDs must be off;
11. if the ERROR LED lights up, go on turning the disk until the ERROR LED
goes off; then go on turning the disk until the ERROR LED lights up
again; finally go on turning the disk until the ERROR LED goes off;
12. stop rotating the disk;
13. remove the battery;
14. short-circuit the battery input terminals and discharge the residual
voltage (connect the WHITE and BLUE wires);
15. switch the 5Vdc power supply off;
16. install and connect the battery again;
17. switch the 5Vdc power supply on; the ERROR LED is on or blinks;
18. switch the 5Vdc power supply off;
19. switch the 5Vdc power supply on;
20. the ERROR LED is off;
21. if you turn the disk, both WARNING and ERROR LEDs are off.
4.6 1Vpp sinusoidal output signals
NOTE
Sinusoidal output signals are only available in SSI and BiSS C-mode encoder
versions (...BG1-... and ...SC1-... order codes).
For any further information on the 1Vpp sinusoidal signals please refer to the “8
- Sine/Cosine output signals” section on page 52.
4.7 Diagnostic LEDs
For any further information on the diagnostic LEDs please refer to the “9 -
Diagnostic LEDs” section on page 54.