5. Installation
series – Matrix Application Mode – User's Manual
48
5. Installation
series – Matrix Application Mode – User's Manual
48
MA
TRIX APPLIC
A
TION MODE
Applied F-series endpoint firmware package: v1.5.4 | Applied R-series endpoint firmware package: v1.5.4 | Applied MMU firmware package: v1.3.3 | LDC software: v2.4.2b4
5.7. Fiber Optical Cable Connections
The section describes how to connect the fiber optical cables between two SFP+ modules and between two
Neutrik opticalCON connectors in case of F and R-series endpoint devices.
5.7.1. Connection between SFP+ Modules
Affected models:
▪
UBEX-PRO20-HDMI-F100
▪
UBEX-PRO20-HDMI-F110
Connect multimode or singlemode
fiber optical cables with LC simplex
connectors to the SFP+ modules like in
the illustration on the right.
ATTENTION!
Always check the
direction of the optical signal. The TX port of the module is higlighted with an arrow pointing outwards
the device, the RX port of the module is higlighted with another arrow pointing inwards the device.
5.7.2. Connection between BiDi (Bidirectional) SFP+ Modules
Affected models:
▪
UBEX-PRO20-HDMI-F100
▪
UBEX-PRO20-HDMI-F110
Connect multimode or singlemode
fiber optical cables with LC simplex
connectors to the BiDi SFP+ modules
like in the illustration on the right.
ATTENTION!
The Module A must be connected to the Module B. Always check the
wavelength
of the BiDi
modules. If the wavelengths are different, the cabling might be also different and the modules shall be
connected
across
.
5.7.3. Connection between Neutrik opticalCON DUO Connectors
Affected models:
▪
UBEX-PRO20-HDMI-R100
2xMM-2xDUO
▪
UBEX-PRO20-HDMI-R100
2xSM-2xDUO
Connect multimode or singlemode fiber optical
cables with LC simplex connectors to the Neutrik
opticalCON DUO connectors like in the illustration on
the right.
ATTENTION!
Always check the direction of the
optical signal.
The Port A must be connected to the
Port B.
5.7.4. Connection between Neutrik opticalCON DUO BiDi Connectors
Affected model:
▪
UBEX-PRO20-HDMI-R100
2xSM-BiDi-DUO
Connect multimode or singlemode fiber optical
cables with LC simplex connectors to the Neutrik
opticalCON DUO connectors like in the illustration on
the right.
ATTENTION!
Always check the direction of the
optical signal.
The Port A must be connected to the
Port B.