10. Appendix
RAP-B511 series
– User's Manual
70
10.2.
Wiring Guide for RS-232 Data Transmission
Room Automation Panel is built with 3-pole Phoenix connector. See
the below examples of connecting to a DCE (Data Circuit-terminating
Equipment) or a DTE (Data Terminal Equipment) type device:
Lightware device and a DCE
D-SUB 9 - Phoenix
Lightware device and a DTE
D-SUB 9 - Phoenix
TX RX
1
6
9
5
2: TX data transmit
3: RX data receive
5: Ground
TX RX
1
6
9
5
2: TX data receive
3: RX data transmit
5: Ground
INFO: The RAP-B511 series works as a DCE unit according to its
pin-out.
10.3. Factory Default Settings
Parameter
Setting/Value
Button settings
Button enabled
true
Operation mode
0
Interaction state
true
EnabLED
true
LED function for True state
off
LED function for False state
off
Button LED lowbright level
2
Button LED highbright level
5
Network settings
IP address
192.168.0.100
Subnet mask
255.255.255.0
Static gateway
192.168.0.1
DHCP
Disabled
LW2 port number
10001
LW3 port number
6107
HTTP port number
80
RS-232 settings
Control protocol
LW2
Baud rate
57600
Databits
8
Parity
No
Stopbits
1
Operation mode
Command Injection
Command injection port nr.
8001
Recognizer delimiter
0D0A
Recognizer Timeout
0 (disabled)
Recognizer Active property timeout
50
Parameter
Setting/Value
IR port settings
Command injection status
Enabled
Command injection input port nr.
9001
GPIO port settings
Output level
High
Direction
Input