manualshive.com logo in svg
background image

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  Page 4 of 13 

SC910D/SC910W DMX CONTROLLER 

Version 2.1   

 

 

 

 

 

 

 

 

   

OWNERS MANUAL  

 

 

 

 

 

 

 

 

 

    11/02/2020 

www.lightronics.com 

Lightronics Inc.   

 

 

 

 

 

 

 

 

509 Central Drive Virginia Beach, VA 23454  

 

 

 

 

 

   757 486 3588 

pair data  cable(s).  One  pair  carries  the  data,  while the 
other  pair  supplies  power  to  the  remote  stations. 
Multiple  smart  remotes  of  different  types  can  be 
connected to this bus.  
 
An  example  using  an  AC1109  and  an  AF2104  smart 
remote wall station is shown below. 
 

 

 
SC910W INSTALLATION 

 

The  SC910W  (or  wall  mount)  is  designed  to  fit  in  a 
standard  5  gang  “new  work”  style  junction  box.  Be 
certain to keep line voltage connections away from the 
SC910W and the junction box housing the unit. A trim 
plate is included with the SC910W. 

 

SC910W POWER & DMX CONNECTIONS 

 

The  SC910W  uses  an  external  12  Volt/3  Amp,  DC 
power supply, which is included. Connecting power to 
a wall mount will require connecting the positive wire 
to the +12V terminal and the negative wire to the -12V 
terminal on the two pin J1 connector located on the back 
of the device.   
 
When  making  power  and  DMX  connections  to  the 
device, make all low voltage connections and check DC 
output prior to mating the connector with the male pins 
located on the rear of the SC910W. Do not make any of 
the  connections  with  voltage  present  or  while  any 
devices on the DMX data chain are transmitting. 
 
DMX is installed in a similar way on the removable 6 
pin  connector  J2.  The  figure  below  shows  the  proper 
wiring of the power and DMX connections. 

 

 

 

SC910W SIMPLE REMOTE CONNECTIONS 
 

 

The  upper  five  terminals  of  J3  are  used  to  connect 
simple switch remote signals. They are marked as COM, 
SW1,  SW2,  SW3  and  COM.  The  COM  terminals  are 
connected to each other on the printed circuit board.  
 
An example with two switch remotes is shown below. 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
The  example  uses  a  Lightronics  APP01  switch  station 
and  a  typical  pushbutton  momentary  switch.  If  the 
SC910W  simple  switch  functions  are  set  to  factory 
default  operation,  then  the  switches  will  operate  as 
follows: 
  

1. 

Scene  #1  will  be  turned  on  when  the  toggle 
switch is pushed up. 

2. 

Scene  #1  will  be  turned  off  when  the  toggle 
switch is pushed down. 

3. 

Scene #2 will be turned on or off each time the 
pushbutton momentary switch is pressed

.  

 

Содержание SC910D

Страница 1: ...SC910D SC910W DMX CONTROLLER Version 2 1 11 02 2020...

Страница 2: ...DMX CHANNELS 6 OPERATION WITH ANOTHER DMX CONTROLLER 6 OPERATION WITH REMOTE STATIONS 6 __________________________________________________________________ SCENE OPERATION 6 RECORDING SCENES 6 RECALLI...

Страница 3: ...ONNECTIONS A 120 Volt AC power outlet is needed for the power supply The SC910D includes a 12 Volt 3 Amp DC power supply that has a 2 1mm barrel connector with POSITIVE center pin TURN OFF ALL CONSOLE...

Страница 4: ...of the device When making power and DMX connections to the device make all low voltage connections and check DC output prior to mating the connector with the male pins located on the rear of the SC910...

Страница 5: ...itted ON DMX is being received DMX is being transmitted REC SWITCH AND REC LED The RECORD switch is a pushbutton recessed below the face plate to prevent accidental operation of the record function It...

Страница 6: ...evel for each of the DMX channels to regain normal operation to a value of 0 on the fader It is important to note which channels have been parked so they can be changed later if needed OPERATION WITH...

Страница 7: ...full for each fixture to one push button a control group can be created Each fixture s respective RED GREEN and BLUE channel can then be assigned to a common fader allowing for seamless control of th...

Страница 8: ...onds Numbers 0100 and larger will be recorded as even minutes and the last two digits will not be used In other words seconds will be ignored After accessing a function 11 32 as described in ACCESSING...

Страница 9: ...FUTURE EXPANSION SCENE 8 ALL SCENES RECORD LOCKOUT Disables scene recording Applies to all scenes SETTING SYSTEM CONFIGURATION OPTIONS 2 Function Code 38 SCENE 1 SAVED FOR FUTURE EXPANSION SCENE 2 MA...

Страница 10: ...4 using the steps outlined in ACCESSING AND SETTING FUNCTIONS the indicators for the current starting scene will flash back as a four digit code The following steps will allow you to change the curren...

Страница 11: ...ses are set to the proper DMX channels Make sure the DMX daisy chain is wired properly and terminated CLEANING The best way to prolong the life of your SC910 is to keep it dry cool and clean COMPLETEL...

Страница 12: ...20 331 340 300 30 81 90 50 30 341 350 300 10 30 91 100 50 30 10 351 360 300 50 101 110 100 361 370 300 50 10 111 120 100 10 371 380 300 50 20 121 130 100 20 381 390 300 50 30 131 140 100 30 391 400 30...

Страница 13: ...Page 13 of 13 SC910D SC910W DMX CONTROLLER Version 2 1 OWNERS MANUAL 11 02 2020 www lightronics com Lightronics Inc 509 Central Drive Virginia Beach VA 23454 757 486 3588 SC910 PROGRAMMING DIAGRAM...

Страница 14: ...not cover loss or damage direct or indirect arising from the use or inability to use this product F Lightronics reserves the right to make any changes modifications or updates as deemed appropriate by...

Отзывы: