FlightTransport Installation Guide
505-003686-00000 Rev A
2-27
2.10.1.
Dry Contact Alarm outputs
The FL 100 offers an optional alarm output to drive a relay or other
device upon system failure. The alarm relay has dry contacts which are
rated for a maximum of 200 mA. The alarm relay forms a “Make”
(Normally Open) connection between the two pins on any of the
following conditions:
Loss of power to the linkhead
Too much received power from Free Space (Overload)
Too low received power from Free Space (Beam is Blocked)
The dry alarm output pins are accessed with the same screw-type
connector that is used for the local power supply arrangement.
TOP
Dry Contact alarms
Connector