Silhouette SD

Indirect/Direct pendant, 2 lamp, T5/HO

Page 3 of 3

Philips Lightolier

e: [email protected]

t:  (508) 679-8131,  Technical info. (978) 657-7600

w: www.lightolier.com
SD  September 7, 2012
Specifications are subject to change without notice. 

© Koninklijke Philips Electronics N.V., 2012. All rights reserved.

Zonal lumen summary

Zone

Lumens

% Lamp

% Fixt.

0- 90

979

16.9

20.5

90-180

3790

65.3

79.5

0-180

4769

82.2

100.0

Photometry

Efficiency: 

 82.2% 

Lumens:

   

2900 lm

Lamps:

   

(2) F28T5

Catalog number:

 SD241281WH 

Report number:

 

LRL 299-1F

Vertical

Horizontal Angle

Angle

0

22.5

45

67.5

90

0

286

286

286

286

286

5

286

286

289

287

287

15

281

284

286

286

282

25

269

270

272

272

272

35

243

246

247

238 239

45

204

210

201

198

198

55

173

172

166

119

172

65

113

112

125

139

143

75

71

83

102

117

120

85

21

46

64

76

80

95

10

29

47

58

61

105

47

71

71

73

75

115

219

314

284

270

256

125

389

513

555

549

536

135

582 688

781

823 780

145

732

810

885

967

974

155

890

942 1059 1097 1112

165

1006 1029 1097 1128 1142

175

1051 1081 1104 1117 1111

180

1088 1089 1094 1096 1097

Ceiling: 

80

70

50

Wall:

70 50 30 70 50 30 50 30 10

RCR 0 82 82 82 73 73 73 55 55 55

1 75 71 68 66 63 60 48 46 44

2 68 62 57 60 55 51 42 39 37

3 62 54 49 54 48 43 37 33 31

4 57 48 42 50 43 37 32 29 26

5 52 43 36 45 38 32 29 25 22

6 47 38 32 42 34 28 26 22 19

7 44 34 28 38 30 25 23 19 17

8 40 31 25 36 27 22 21 17 15

9 37 28 22 33 25 20 19 15

13

10 35 25 19 31 22 17 17 14

11

Based on a floor reflectance of 0.2

Candela distribution

Coefficients of utilization (%)

Candela curve

8” (20.32cm)

4”
(10.16cm)

4” (10.16cm)

3.4”

(8.64cm)

4.6” (11.68cm)

4” (10.16cm)

8”

(20.32cm)

4”
(10.16cm)

2,000

700

500

400

200

FOOTCANDLE

20

30

50

70 100

1

2

3

4 5

7

10

20

30 40 50 70 100

200

ROOM AREA IN SQUARE FEET

NUMBER OF FIXTURES REQUIRED

300

1,000

100

90˚
85˚

95˚

105˚

75˚

65˚

55˚

115˚

125˚

180˚  175˚      165˚        155˚          145˚               135˚

0˚    5˚        15˚           25˚            35˚                 45˚

500

250

750

500

1000

250

1250

1250

1000

750

0

90˚

90˚
85˚

95˚

105˚

75˚

65˚

55˚

115˚

125˚

180˚  175˚      165˚        155˚          145˚               135˚

0˚    5˚        15˚           25˚            35˚                 45˚

500

250

750

500

1000

250

1250

1250

1000

750

0

90˚

Calculations are for 28 watt T5 lamps, for 54 watt T5 lamps  

multiply by 1.7

Quick calculator and ceiling brightness

8” (20.32cm)

4”
(10.16cm)

4” (10.16cm)

3.4”

(8.64cm)

4.6” (11.68cm)

4” (10.16cm)

8”

(20.32cm)

4”
(10.16cm)

2,000

700

500

400

200

FOOTCANDLE

20

30

50

70 100

1

2

3

4 5

7

10

20

30 40 50 70 100

200

ROOM AREA IN SQUARE FEET

NUMBER OF FIXTURES REQUIRED

300

1,000

100

90˚
85˚

95˚

105˚

75˚

65˚

55˚

115˚

125˚

180˚  175˚      165˚        155˚          145˚               135˚

0˚    5˚        15˚           25˚            35˚                 45˚

500

250

750

500

1000

250

1250

1250

1000

750

0

90˚

90˚
85˚

95˚

105˚

75˚

65˚

55˚

115˚

125˚

180˚  175˚      165˚        155˚          145˚               135˚

0˚    5˚        15˚           25˚            35˚                 45˚

500

250

750

500

1000

250

1250

1250

1000

750

0

90˚

1.  Find room area on vertical axis.

2.  Move across chart to footcandle 

curve.

3.  Move down to horizontal axis and 

read number of fixtures required.

Reflectance of 80% ceiling, 50% walls and 20% floor. Light loss factor is .85, Room size is 50' x 50',  

Run Spacing 10’. Ceiling Height 9’ to 12’. Values are taken from the center of the room.

Suspension Length

12"

 18"

 24"

Footlamberts Above Fixture 

209

143

110

Footlamberts Between Fixtures 

20.7

21.1

23.9

Ceiling Brightness Ratio 

10.1

6.8

4.6