background image

Silhouette SD

Indirect/Direct pendant, 2 lamp, T5/HO

Page 1 of 3

Catalog number:
Notes:

Type:

5

2

4

3

1

2-1/4"

(5.72 cm)

6-1/16" (15.4 cm)

1-3/16" (3.02 cm)

Half scale

Ordering information

1

= 120v

2

= 277v

28

= 28 watts

54

= 54 watts

J

2

Voltage

Finish

Options

Type

Wattage

Length

Light 

source

J

= Joiner

WH

= White

AL

= Aluminum

2

= 2 lamp 

T5

4

=4 foot

8

=8 foot

M7

= 0-10v dimming

DS

= Dual switching

X4

= One additional pair of 

thru wires

X5

= Two additional pairs of 

thru wires

Family

SD

Silhouette 

SD

Features

1. Housing:

 Extruded aluminum. Die-cast end plate mechanically attached with 

no exposed fasteners. 

2.  Light source:

 Two T5 (28 or 54 watt as specified) fluorescent lamps  per 

4-foot section. Provided by others. Factory installed lamps optional  

(consult factory).

3. Reflector:

 Die-formed specular aluminum reflector.

4. Shielding:

 Die-formed 18 gauge CRS.

5. Diffuser:

 Translucent acrylic diffuser.

Electrical

Specify 120 volt or 277 volt. Three conductor, 18 gauge wire. For special circuiting, 

consult factory. Ballast is class "P" electronic, class "A" sound rating, less than 10% 

THD, thermally protected, end of lamp life cutoff. Standard ballast dimensions 

1-1/8" X 1", 0-10v dimming standard. For other dimming options consult factory.  

Factory installed ballast disconnect as required by National Electrical code.

Mountings

Cable suspension:

  5-1/4" (13.3 cm) diameter canopy powder coated matte 

white, 1/16" (0.16cm) diameter galvanized steel aircraft cable adjustable up to 48" 

(122cm). Gripping with cable adjustment. Draw tight connector create hairline 

seam between joiner modules.

Finish

Powder coated matte white or aluminum finish.  Custom colors available, consult factory.

Options and Accessories

L, T, X inline joiner blocks and emergency battery pack available. Consult factory.

Ordering Instructions

Individual Fixtures:

1. Order one JOINER MODULE.

2. Order one POWER FEED END SET.

3. Order one CABLE ASSEMBLY.

Continuous Rows:

1. Determine run length.

2. Order the appropriate number of JOINER MODULES to complete the run.

3. Order one POWER FEED END SET per run.

4. Order one CABLE ASSEMBLY per JOINER MODULE.

5.  For patterns that exceed amperage limits, order the appropriate number of 

CABLE/CORD FEEDS.

Square/Rectangle Patterns:

1. Order appropriate number of JOINER MODULES to complete the pattern size.

2. Order number and type of JOINER BLOCKS required.

3.  Order one CABLE/CORD ASSEMBLY or POWER FEED END SET to power the 

pattern.

4.  For patterns that exceed amperage limits, order the appropriate number of 

CABLE/CORD FEEDS.

Approvals

Certified to UL, CSA standards.

Отзывы: