Lighting Systems
Baselyte-BSL5
Page 4 of 8
2 Light T5 HO Direct/Indirect
Lightolier
a Genlyte Company
www.lightolier.com
63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.
Job Information
Type:
Mount Type: T-Bar Fixed Position (1/4-20 Threaded Rod)
Mount Type: T-Bar Variable Position
Mount Type: Support or Open-Joist Ceiling
Supension Length
Non-Power Mount
1-Power Mount
2-Power Mount
1-Power Mount
2’
4’
8’
12’
3 Conductor
BSLM2102P13 BSLM2104P13 BSLM2108P13 BSLM2112P13
4 Conductor
BSLM2102P14 BSLM2104P14 BSLM2108P14 BSLM2112P14
2-Power Mount
3 Conductor
BSLM2102P23 BSLM2104P23 BSLM2108P23 BSLM2112P23
Non-Power Mount
BSLM2102N
BSLM2104N
BSLM2108N
BSLM2112N
Supension Length
1-Power Mount
2’
4’
8’
12’
3 Conductor
BSLM5102P13 BSLM5104P13 BSLM5108P13 BSLM5112P13
4 Conductor
BSLM5102P14 BSLM5104P14 BSLM5108P14 BSLM5112P14
7 Conductor
BSLM5102P17 BSLM5104P17 BSLM5108P17 BSLM5112P17
2-Power Mount
3 Conductor
BSLM5102P23 BSLM5104P23 BSLM5108P23 BSLM5112P23
Non-Power Mount
BSLM5102N
BSLM5104N
BSLM5108N
BSLM5112N
Supension Length
1-Power Mount
2’
4’
8’
12’
3 Conductor
BSLM3102P13 BSLM3104P13 BSLM3108P13 BSLM3112P13
4 Conductor
BSLM3102P14 BSLM3104P14 BSLM3108P14 BSLM3112P14
7 Conductor
BSLM3102P17 BSLM3104P17 BSLM3108P17 BSLM3112P17
2-Power Mount
3 Conductor
BSLM3102P23 BSLM3104P23 BSLM3108P23 BSLM3112P23
Non-Power Mount
BSLM3102N
BSLM3104N
BSLM3108N
BSLM3112N
Non-Power Mount
1-Power Mount
2-Power Mount
Non-Power Mount
1-Power Mount
2-Power Mount
• Meets UBC, OSHPD and DSA seismic requirements
• Canopy: Diameter of 5 /4“x 3/4” (power)
• Cable: 7x7 stranded aircraft cable
• Tile cut-out hole: Diameter of 2 /2” (power) or 3/4” (non-power)
• J-Box: Integral J-Box supplied
• /4 - 20 all thread rod (supplied by others)
• Fully vertically adjustable at fixture
•
Meets UBC, OSHPD and DSA seismic requirements
•
Canopy: Diameter of 5
/4
“x
3/4
”
(power)
• Cable: 7x7 stranded aircraft cable
• Versatile mount, fully adjustable to accomodate open sloped ceilings
• J-Box: 4” octogonal box (supplied by others)
• Fully vertically adjustable at fixture
• Meets UBC, OSHPD and DSA seismic requirements
• Canopy: Diameter of 3“x 7/32”
• Cable: 7x7 stranded aircraft cable
• Tile cut-out hole: Diameter of 2 /4”
• Aligned by T-bar and secured to structure
• J-Box 4” square (supplied by others)
• Fully vertically adjustable at fixture
• Adjusts to both ” and /2” high T-bar systems
*Note
: Supports 5/6”, 9/6” and slot grid ceiling types.