Lighting Systems
Baselyte-BSL5
Page 2 of 8
2 Light T5 HO Direct/Indirect
Lightolier
a Genlyte Company
www.lightolier.com
63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.
Job Information
Type:
Performance
Candlepower Curve
Candlepower Summary
Coefficients of Utilization
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
Module Lengths & Mounting Distances
Joiner
BSLESW
= suspended standard white
End Set
BSLJS
= suspended joiner
System Components & Accessories
Run Configuration
*Note
: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.
Report No:
20640
Lamps:
F54T5
Lumens per Lamp:
4650
Efficiency:
82.2%
Up:
79.4%
Down:
20.6%
Run
Length
4’
Module
8’
Module
2’
Module
Joiner
End Set
Mount
Power
Mount*
4’ run
8’ run
2’ run
6’ run
2
2
20’ run
2
24’ run
2
2
28’ run
2
2
3
32’ run
2
2
3
Zonal Lumen Summary
ZONE
LUMENS %BARE LAMP %LUMINAIRE
CANDLEPOWER SUMMARY
ZONE
CANDLEPOWER
DEG.
0
22.5
45
67.5
90
180
1598
1598
1598
1598
1598
175
1590
1592
1596
1601
1602
165
1536
1546
1557
1567
1573
155
1434
1449
1474
1493
1505
145
1286
1306
1365
1439
1461
135
1092
1123
1249
1357
1397
125
865
922
1111
1274
1338
115
613
712
988
1191
1254
105
339
524
804
847
904
95
84
222
379
363
427
90
5
34
48
61
59
85
15
33
56
63
68
75
55
54
77
91
99
65
113
131
82
96
103
55
259
254
190
101
99
45
431
338
355
266
254
35
609
510
469
445
447
25
770
726
593
533
548
15
901
915
857
745
730
5
979
981
998
999
1007
0
987
987
987
987
987
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80
70
50
% WALL REFLECTANCE
50
30
10
50
30
10
50
30
10
0
82
82
82
73
73
73
55
55
55
1
72
69
66
63
61
59
48
46
45
2
63
58
54
56
52
48
42
40
37
3
55
50
45
49
44
41
37
34
32
4
49
43
38
44
38
34
33
30
27
5
44
37
33
39
34
30
30
26
23
6
39
33
28
35
30
26
27
23
20
7
35
29
25
31
26
22
24
21
18
8
32
26
22
28
23
20
22
18
16
9
29
23
19
26
21
18
20
17
14
10 26
21
17
24
19
16
19
15
13
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP
%LUMINAIRE
0-90
90-180
0-180
7646
6073
1573
20.6
79.4
100.0
16.9
65.3
82.2
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80
70
50
% WALL REFLECTANCE
50
30
10
50
30
10
50
30
10
0
82
82
82
73
73
73
55
55
55
1
72
69
66
63
61
59
48
46
45
2
63
58
54
56
52
48
42
40
37
3
55
50
45
49
44
41
37
34
32
4
49
43
38
44
38
34
33
30
27
5
44
37
33
39
34
30
30
26
23
6
39
33
28
35
30
26
27
23
20
7
35
29
25
31
26
22
24
21
18
8
32
26
22
28
23
20
22
18
16
9
29
23
19
26
21
18
20
17
14
10 26
21
17
24
19
16
19
15
13
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP
%LUMINAIRE
0-90
90-180
0-180
7646
6073
1573
20.6
79.4
100.0
16.9
65.3
82.2
Note
: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).