background image

Lighting Systems

 

Baselyte-BSL26

Page 7 of 8  

2 Light T5 HO Indirect

Lightolier 

a Genlyte Company 

www.lightolier.com

63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470

We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.

Job Information 

Type:

Wiring Options: 2 Circuit Left/Right Switching

Type 6: 

Chloride standard 

CTP700

Type N

: Bodine standard 

LP550

Type F: 

Chloride high performance 

CTP300

Type 

Q

Bodine high performance 

LP600 

Fixture wired for two circuits (left/right switching), plus a battery pack is wired to one lamp. A 
hot lead is connected to the battery pack and would act as a ‘trigger’ wire when connected to a 
constant hot by installer. Leads for both normal circuit and battery pack are wired to fixture ends. 

2 Circuit Left/Right Switching with Emergency Battery Pack (EM)

2 Circuit Left/Right Switching with Emergency Circuit/Night Light (EC/NL)

One 4’ section in two circuit fixture (left/right switching) to be wired on a separate thru circuit. 
Leads for both normal circuit and EC/NL circuit wired to fixture ends. All lamps in EC/NL section to 
be wired together.

Type 4: 

2cct. w/EC/NL 

Fixture wired for two circuit. Lamps wired for left/right switching.

2 Circuit Left/Right Switching

Type 2: 

2cct.

Type 9:

 2cct. w/cct. thru wire

Type 

I

2cct. w/2cct. thru wire

One 4’ section in a two circuit fixture (left/right switching) to be wired on a separate thru circuit, 
in addition, a battery pack is wired to one lamp. Installer can connect ‘trigger’ wire to EC hot lead 
if controlled together or wired separately if controlled independently. Leads for both normal circuit, 
EC/NL and battery pack are wired to fixture ends. All lamps in EC/NL section to be wired together.

2 Circuit Left/Right Switching with Emergency Circuit/Night Light and Emergency Battery Pack

Type K: 

Chloride standard 

CTP700

%#.,

%#.,

%-

%#.,

%#.,%-

*Note: Multi-lamp battery packs are also available.

*Note: Multi-lamp battery packs are also available.

Содержание Baselyte-BSL26

Страница 1: ...277V Finish High quality white powder coat with textured matte finish Custom colors available Consult factory Mounting Aircraft cable gripper is tamper resistant and provides infinite vertical adjustm...

Страница 2: ...0 0 0 0 65 0 0 0 0 0 55 0 0 0 0 0 45 0 0 0 0 0 35 0 0 0 0 0 25 0 0 0 0 0 15 0 0 0 0 0 5 0 0 0 0 0 0 0 0 0 0 0 COEFFICIENTS OF UTILIZATION EFFECTIVE CEILING CAVITY REFLECTANCE 80 70 50 WALL REFLECTANCE...

Страница 3: ...ed aircraft cable Supported by T bar and secured to structure J Box 4 square supplied by others Fully adjustable vertically at fixture 65 lbs maximum load Canopy Diameter of 3 3 4 x 7 32 Cable 7x7 str...

Страница 4: ...th 1 Power Mount 2 4 8 12 3 Conductor BSLM3102P13 BSLM3104P13 BSLM3108P13 BSLM3112P13 4 Conductor BSLM3102P14 BSLM3104P14 BSLM3108P14 BSLM3112P14 7 Conductor BSLM3102P17 BSLM3104P17 BSLM3108P17 BSLM31...

Страница 5: ...or BSLM1102P23 BSLM1104P23 BSLM1108P23 BSLM1112P23 Non Power Mount BSLM1102N BSLM1104N BSLM1108N BSLM1112N Meets UBC OSHPD and DSA seismic requirements Canopy Diameter of 5 1 4 x 3 4 power Cable 7x7 s...

Страница 6: ...ance LP600 All lamps wired on one circuit plus a battery pack is wired to one lamp A hot lead is connected to the battery pack and would function as a trigger wire when connected to a constant hot by...

Страница 7: ...hing with Emergency Circuit Night Light EC NL One 4 section in two circuit fixture left right switching to be wired on a separate thru circuit Leads for both normal circuit and EC NL circuit wired to...

Страница 8: ...B switching in alternate 4 sections 2 Circuit A B Switching alternate 4 sections 2 Circuit A B Switching alternate 4 sections with Emergency Circuit Night Light EC NL One 4 section in a two circuit f...

Отзывы: