background image

Lighting Systems

 

Baselyte-BSL26

Page 2 of 8  

2 Light T5 HO Indirect

Lightolier 

a Genlyte Company 

www.lightolier.com

63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470

We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.

Job Information 

Type:

Performance

Candlepower Curve

Candlepower Summary

Coefficients of Utilization

Module Lengths & Mounting Distances

Joiner

BSLESW

 = suspended standard white

End Set

BSLJS

 = suspended joiner

System Components & Accessories

Run Configuration 

Run

Length

 

4’ 

Module

8’

Module

2’ 

Module

Joiner

End Set

Mount

Power 

Mount*

4’ run

8’ run

2’ run

6’ run

2

2

20’ run

2

24’ run

2

2

28’ run

2

2

3

32’ run

2

3

Report No:

 207

Lamps: 

F54T5

Lumens per Lamp: 

4650

Efficiency:

 96.9%

Up:

 00.0%  

Down:

 0.0%

Zonal Lumen Summary

ZONE 

LUMENS    %BARE LAMP       %LUMINAIRE

-ODULE,ENGTH

-OUNTING$ISTANCE

-ODULE,ENGTH-OUNTING$ISTANCE

-ODULE,ENGTH-OUNTING$ISTANCE

@

@

@

CANDLEPOWER SUMMARY

ZONE

CANDLEPOWER

DEG.

0

22.5

45

67.5

90

180

2352

2352

2352

2352

2352

175

2339

2344

2352

2359

2363

165

2252

2281

2324

2362

2376

155

2092

2153

2252

2343

2374

145

1862

1966

2143

2269

2305

135

1572

1730

1970

2121

2163

125

1234

1460

1729

1899

1957

115

858

1119

1448

1621

1661

105

475

770

1082

1119

1139

95

113

267

458

389

406

90

5

4

13

6

8

85

0

0

0

0

0

75

0

0

0

0

0

65

0

0

0

0

0

55

0

0

0

0

0

45

0

0

0

0

0

35

0

0

0

0

0

25

0

0

0

0

0

15

0

0

0

0

0

5

0

0

0

0

0

0

0

0

0

0

0

COEFFICIENTS OF UTILIZATION

% EFFECTIVE CEILING CAVITY REFLECTANCE

80

70

50

% WALL REFLECTANCE

50

30

10

50

30

10

50

30

10

0

91

91

91

78

78

78

53

53

53

1

79

76

73

68

65

62

46

44

43

2

69

64

59

59

55

51

40

38

35

3

60

54

49

52

46

42

35

32

30

4

53

46

41

45

40

35

31

28

25

5

47

40

35

40

34

30

28

24

21

6

42

35

29

36

30

26

25

21

18

7

37

30

25

32

26

22

22

18

15

8

34

27

22

29

23

19

20

16

13

9

30

24

19

26

20

17

18

14

12

10 27

21

17

24

18

15

16

13

10

ZONAL LUMEN SUMMARY

ZONE LUMENS % BARE LAMP

%LUMINAIRE

0-90
90-180
0-180

8923

8923

0

0
100.0
100.0

0
95.9
95.9

COEFFICIENTS OF UTILIZATION

% EFFECTIVE CEILING CAVITY REFLECTANCE

80

70

50

% WALL REFLECTANCE

50

30

10

50

30

10

50

30

10

0

91

91

91

78

78

78

53

53

53

1

79

76

73

68

65

62

46

44

43

2

69

64

59

59

55

51

40

38

35

3

60

54

49

52

46

42

35

32

30

4

53

46

41

45

40

35

31

28

25

5

47

40

35

40

34

30

28

24

21

6

42

35

29

36

30

26

25

21

18

7

37

30

25

32

26

22

22

18

15

8

34

27

22

29

23

19

20

16

13

9

30

24

19

26

20

17

18

14

12

10 27

21

17

24

18

15

16

13

10

ZONAL LUMEN SUMMARY

ZONE LUMENS % BARE LAMP

%LUMINAIRE

0-90
90-180
0-180

8923

8923

0

0
100.0
100.0

0
95.9
95.9

*Note

: Additional power mounts may be required for some runs with T5 HO 

lamping options, longer runs, and runs with wiring options that are more complex. 
Please consult factory for assistance.

Note

: Shaded area indicates locations of emergency sections (emergency wiring  

controls all lamps or optional battery pack controls one or two lamps).

Содержание Baselyte-BSL26

Страница 1: ...277V Finish High quality white powder coat with textured matte finish Custom colors available Consult factory Mounting Aircraft cable gripper is tamper resistant and provides infinite vertical adjustm...

Страница 2: ...0 0 0 0 65 0 0 0 0 0 55 0 0 0 0 0 45 0 0 0 0 0 35 0 0 0 0 0 25 0 0 0 0 0 15 0 0 0 0 0 5 0 0 0 0 0 0 0 0 0 0 0 COEFFICIENTS OF UTILIZATION EFFECTIVE CEILING CAVITY REFLECTANCE 80 70 50 WALL REFLECTANCE...

Страница 3: ...ed aircraft cable Supported by T bar and secured to structure J Box 4 square supplied by others Fully adjustable vertically at fixture 65 lbs maximum load Canopy Diameter of 3 3 4 x 7 32 Cable 7x7 str...

Страница 4: ...th 1 Power Mount 2 4 8 12 3 Conductor BSLM3102P13 BSLM3104P13 BSLM3108P13 BSLM3112P13 4 Conductor BSLM3102P14 BSLM3104P14 BSLM3108P14 BSLM3112P14 7 Conductor BSLM3102P17 BSLM3104P17 BSLM3108P17 BSLM31...

Страница 5: ...or BSLM1102P23 BSLM1104P23 BSLM1108P23 BSLM1112P23 Non Power Mount BSLM1102N BSLM1104N BSLM1108N BSLM1112N Meets UBC OSHPD and DSA seismic requirements Canopy Diameter of 5 1 4 x 3 4 power Cable 7x7 s...

Страница 6: ...ance LP600 All lamps wired on one circuit plus a battery pack is wired to one lamp A hot lead is connected to the battery pack and would function as a trigger wire when connected to a constant hot by...

Страница 7: ...hing with Emergency Circuit Night Light EC NL One 4 section in two circuit fixture left right switching to be wired on a separate thru circuit Leads for both normal circuit and EC NL circuit wired to...

Страница 8: ...B switching in alternate 4 sections 2 Circuit A B Switching alternate 4 sections 2 Circuit A B Switching alternate 4 sections with Emergency Circuit Night Light EC NL One 4 section in a two circuit f...

Отзывы: