background image

 

Document

: LH-A136-15-OB-OPM-DR-1.00                                        

Page   24 of 37                              

                 © Lighthouse Technologies Ltd. 

HK:   T 

+852 2192 1688                     

F

   +852 2423 1092     

                [email protected]                            www.lighthouse-tech.com

 

3.3 

Power Cable Wiring 

 

3.3.1  AC Power 

 

An approved three-pole appliance coupler inside the panel connects to the AC supply. The AC power cable is then 

connected to the EMI filter and distributes to the power supply units.  Each panel has an earth point for grounding. 
 
Colour of Wire            A.C. Supply connection (for 100V)            A.C. Supply connection (for 240V) 

 

Brown   

           AC. Live  

 

 

             AC. Live  

 

Blue 

 

           AC. Neutral 

 

 

 

AC. Neutral 

Green/Yellow 

           AC. Protective earth 

 

 

AC. Protective earth 

 
 

3.3.2

 

Number of Power Cords 

 
1)

 

Countries using 110V AC : The product contains two input power supply cords intended for connection with 
two independent AC power source. 

 

2)

 

Countries using 220V AC : The product contains one input power supply cord intended for connection with one 
independent AC power source. 

 

3.3.3

 

DC Power 

 

DC  power  from  each  power  supply  unit  provides  low  voltage  power  to  the  assigned  electronics  components,  for 
example,  driver  board,  and  fans,  the  responding  color  of  the  wire  represents  the  relevant  component´

s  power 

connection, please note the list below for a clear cabling configuration. 
 
Colour of wire   

 

 

 

 

 

D.C. Supply connection 

 

White   

 

 

 

 

 

 

Green LED / Blue LED / Red LED /TTL  

Black 

 

 

 

 

 

 

 

GND  

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание A136-15-OB

Страница 1: ...Technologies Ltd HK T 852 2192 1688 F 852 2423 1092 info lighthouse tech com www lighthouse tech com 1 5625 mm Pixel Pitch with SMD LEDs A136 15 OB All in one LED Display A modular system for indoor a...

Страница 2: ...cking Store in a dry and airy place Suggest using below method to cleaning the Intelligent Modules IM Using electrostatic proof soft brush to clean the IM per month to keep the LEDs clean Clean with s...

Страница 3: ...3 3 2 2 Earth Leakage Considerations 23 3 2 3 Inrush current and Over current Considerations 23 3 2 4 Earthing 23 3 2 5 EMC Statement 23 3 2 6 FCC Statement 23 3 3 Power Cable Wiring 24 3 3 1 AC Power...

Страница 4: ...system components and interconnection methods If any details in this document are unclear please contact your local representative or the head office for more details 1 1 Brief Description of Purpose...

Страница 5: ...ratio 16 9 Ingress protection Front rear IP IP40 IP20 Operating storage temperature deg C 0 to 40 10 to 50 Operating storage humidity 90 Without condensation Pixel type and configuration R G B SMD 3 i...

Страница 6: ...dicator light Standby light red Power light green Button customizable Brightness Keys up down button Standby Power On Button Other Ports USB3 0 1xUSB3 0 supports Ultra highspeed USB device USB2 0 2xUS...

Страница 7: ...ini Card Convertor Board 2 in 1 36 7 12V 200W Switched Mode Power Supply 1 8 3 8V 189W Switched Mode Power Supply 18 9 EMI RFI AC power line filter 2 2 1 1 Component Placement There are five kinds of...

Страница 8: ...e is fitted with 28880 LEDs plus associated drive electronics Electrical connections low voltage power and digital data are made to the rear of each intelligent module from inside of the enclosure Fig...

Страница 9: ...lay is designed to be mounted on the stand sold separately or on the wall When installing it is important to ensure that the entire screen is correctly aligned both vertically and horizontally 3 1 Ins...

Страница 10: ...ion plate PANEL CENTER LINE HORIZONTAL PANEL CENTER LINE HORIZONTAL Step2 Install the right plate with connection plate PANEL CENTER LINE HORIZONTAL PANEL CENTER LINE HORIZONTAL Use 16pcs M3X12 screw...

Страница 11: ...RIZONTAL PANEL CENTER LINE HORIZONTAL PANEL CENTER LING VERTICAL PANEL CENTER LING VERTICAL Step4 Double check the dimension after assembling PANEL CENTER LINE HORIZONTAL PANEL CENTER LINE HORIZONTAL...

Страница 12: ...F 852 2423 1092 info lighthouse tech com www lighthouse tech com Step5 Remove the bottom connection plate after installation PANEL CENTER LINE HORIZONTAL PANEL CENTER LINE HORIZONTAL PANEL CENTER LIN...

Страница 13: ...F 852 2423 1092 info lighthouse tech com www lighthouse tech com 2 Screen assembly a First the 8 PCS fixed screw behind the box are assembled to the box and locked with tools b The following figure is...

Страница 14: ...nologies Ltd HK T 852 2192 1688 F 852 2423 1092 info lighthouse tech com www lighthouse tech com Installation Guides 1 The two members jointly lifted the right half cabinet and placed it on the Stand...

Страница 15: ...1688 F 852 2423 1092 info lighthouse tech com www lighthouse tech com 3 You need to connect all the cables and install back all the intelligent modules NETWORK CABLE 4PCS Please pay attention to the...

Страница 16: ...3 1092 info lighthouse tech com www lighthouse tech com 4 The cabinet is combined by sliding on the wall mount we must make sure that the steel block is properly connected to the positioning 5 After t...

Страница 17: ...1092 info lighthouse tech com www lighthouse tech com 6 Install and tighten 8 pcs black M4 flat head screws to both top and bottom side of the case 7 Install M4 screws 4 PCS M4 screws 4 PCS M4 screws...

Страница 18: ...om 8 All the intelligent modules LED Panel have labels stuck on the back side Please follow below number to install back the intelligent modules Install the Sensor Box 1 Take out a sensor box Run the...

Страница 19: ...t Module Step1 Power off the LED display Step2 Hold the 2pcs handles push the lock inward and pull the handles toward outside and then take it up Step3 Take the tool up and horizontaly fit it closely...

Страница 20: ...a spare intelligent module and locate the intelligent module to case please pay attention to the arrow direction on the back side of it Step2 Flatten the intelligent module Note When mounting an inte...

Страница 21: ...ighthouse tech com www lighthouse tech com Packaging NOTE The pictures are schematic diagrams Everything is subject to the infact products Carton 1 Pack up the IMs Pack up six intelligent modules into...

Страница 22: ...OB OPM DR 1 00 Page 22 of 37 Lighthouse Technologies Ltd HK T 852 2192 1688 F 852 2423 1092 info lighthouse tech com www lighthouse tech com 2 Pack up the mounting plate 3 Pack up the cabinet and put...

Страница 23: ...ausing unnecessary disconnection of the supply and be able to detect excess currents due to faults within the equipment during normal operation 3 2 4 Earthing Each panel is separately connected to the...

Страница 24: ...eutral Green Yellow AC Protective earth AC Protective earth 3 3 2 Number of Power Cords 1 Countries using 110V AC The product contains two input power supply cords intended for connection with two ind...

Страница 25: ...852 2423 1092 info lighthouse tech com www lighthouse tech com 4 Setting 4 1 The Introduction of A136 15 OB Screen Interface and Function 4 1 1 Remote Controller 4 1 2 Interface Specifications NOTE Th...

Страница 26: ...Document LH A136 15 OB OPM DR 1 00 Page 26 of 37 Lighthouse Technologies Ltd HK T 852 2192 1688 F 852 2423 1092 info lighthouse tech com www lighthouse tech com 4 1 3 Connection...

Страница 27: ...com www lighthouse tech com 4 2 Parameter Settings 4 2 1 Set Up the Connection Turn on the power of the screen use the standard USB cable to connect the computer with the screen open the software Cont...

Страница 28: ...use the standard USB cable to connect the PC and control the LED display through the gigabit network port 4 2 3 Parameter Settings Connect the PC to the display screen successfully the screen paramet...

Страница 29: ...can be set to the main screen PIP1 PIP2 at most the main screen and PIP1 PIP2 can be displayed at the same time Screen adjustment can adjust the color saturation brightness compensation and contrast o...

Страница 30: ...be used connections from the sending card The parameters of the software adjustment can be imported or exported All parameters become default after factory Settings are restored 4 2 6 Detect the Recei...

Страница 31: ...Make sure the IM is firmly mounted as which will affect the water resistance ability of the front panel 7 Power on the panel 8 Please make sure the replaced IM is functioning well Appendix B Trouble S...

Страница 32: ...the corresponding position 3 PSU problems The abnormal module position of IM is not bright the state of the PSU in the corresponding position is power supply abnormally Inspection Replace the PSU in...

Страница 33: ...particularly bright when the screen is white unlike others Inspection Switch calibration off again then switch to calibration on to confirm the existence of calibration data You can also switch IMs da...

Страница 34: ...ocument LH A136 15 OB OPM DR 1 00 Page 34 of 37 Lighthouse Technologies Ltd HK T 852 2192 1688 F 852 2423 1092 info lighthouse tech com www lighthouse tech com Appendix C A136 15 OB Mechanical Assembl...

Страница 35: ...Document LH A136 15 OB OPM DR 1 00 Page 35 of 37 Lighthouse Technologies Ltd HK T 852 2192 1688 F 852 2423 1092 info lighthouse tech com www lighthouse tech com...

Страница 36: ...ocument LH A136 15 OB OPM DR 1 00 Page 36 of 37 Lighthouse Technologies Ltd HK T 852 2192 1688 F 852 2423 1092 info lighthouse tech com www lighthouse tech com Appendix D A136 15 OB Data Wiring Diagra...

Страница 37: ...cument LH A136 15 OB OPM DR 1 00 Page 37 of 37 Lighthouse Technologies Ltd HK T 852 2192 1688 F 852 2423 1092 info lighthouse tech com www lighthouse tech com Appendix E A136 15 OB Power Wiring Diagra...

Отзывы: