Manual F5021B - Parameter list
No.
Marking
Description
Stand.
Area
Unit
Value
F161
Block floor during time
Blocking of floors
(F137,F138,F139)
0: no blocking
1: block with time F131
2: blocking with key-switch
0
0
~
1
F162
Spare
Buffer
F163
OEPS Running
Operation with emergency-power-
supply
0: no
1: possible
0
0
~
1
F164
Load device type
Type of load-measure-equipment
and load-compensation at FU
start.
0: Load measurement via CAN-
Bus, over-load and full-load-switch
via the cabine module, load-
compensation calculated by the
main module.
1: Load measurement and
-compensation via CAN-Bus, over
load and full load calculated by the
main module.
2: Loadmeasurement and
-compensation via CAN-Bus, over
load- and full load switch via the
cabin module.
3: Load measurement via CAN-
Bus, over load, full load, load
compensation calculated by the
main board
2
0
~
3
F165
Door open selection.
Door open functionality:
Bit 1: no open/close during
inspection.
Bit 2: no opening of the door
during test-operation
Bit 3: door A basic position open
at main stop
Bit 4: door A basic position open
at every stop
Bit 5: door B basic position open
at main stop
Bit 6: door B basic position open
at every stop
0
0
~
65535
F166~
167
Spare
Buffer
F168
Lift numbering for IC
card service
RFID card reader
0: no RFID card reader
1~255 adress of the lift
0
0
~
255
F169
Setting landings for
up/down calls by IC
card
RFID card reader generates
0- downwards calls 1- upwards
calls
0
0
~
1
F170
IC card service floor 1
Floors which are only approved
with RFID:
Bit mask Interior calls 1~16
0
0
~
65535
Page 55
Содержание F5021
Страница 1: ...Manual F5021B Lift controller 32 bit system version E02 2 MA ...
Страница 4: ......
Страница 6: ......
Страница 16: ......
Страница 24: ...Manual F5021B Menu tree parameter Page 20 ...
Страница 36: ...Manual F5021B SM02 SM03 cabin module Plug SM03 Nr 1 SM03 Nr 2 SM03 Nr 8 JP8 floor 8 floor 16 floor 64 Page 32 ...
Страница 40: ......
Страница 50: ......