background image

4

  

(13)

inDOMO HP

 - Platform lift

FINAL TESTS

IM.TEC.028.EN_rev.10.2

   -  November 2015

All rights reserved

This manual contains the list of final tests needed for lift commissioning by the installer. Upon the commissioning completed,  the  

installer will sign the protocol, indicating the exact date and the data of the installation company and  special notes, if any.

The manual must  be signed by the owner of the lift, to confirm the final commissioning and handover of the lift and the ownership 

of all the related documentation.

This manual must be filled in, following the instructions stated in the below paragraphs: the manual must be kept nearby the lift  as 

part of the conformity documents; the last page form must be  sent  to the Supplier within 15 days  from the date stated on the form 

itself, so that the warranty period can start in due time.   

Should the form not be sent as per the above instructions, the warranty will start on the date of shipment and will not exceed the 

standard term.

The single tests described below are to verify the correct assembly: each of them contains the requirements to be matched and the 

way to check them.

The operations described in this paragraph, can be carried out by adequately qualified personnel.

The below listed operations  are to support standard test procedures required by project and electrical drawings.

Should any of these operations lead to negative results,  the  related assembly operation must be repeated in accordance with 

installation instructions.

Before accessing the pit, open the main driving forse switch and activate the safe pit device.

Some of the operations require that the control cabinet be open and under power.

The tests are to be effected with the empty car, except those cases when the load is required.

NOTE 1

: When the tests are to be effected “with the maximum static load”, the car must be evenly loaded as follows:

Nominal car load (kg)

250

315

385

500

Weight to be loaded (kg)

313

394

481

625

NOTE 2

: When the tests are to be effected “with the maximum load”, the car must be evenly loaded with the weight equal to the 

nominal load  (indicated on the car plate).

NOTE 3

: When the instructions recommend to “Refresh”, go backwards through the steps described, to bring the lift back to the 

starting conditions.

COMMISSIONING AND HANDOVER

CONFORMITY TESTS

Содержание InDomo HP

Страница 1: ...a Caduti del Lavoro 16 43058 Bogolese Sorbolo PR Italy Phone 39 0521 695311 Fax 39 0521 695313 www verticogroup it info liftingitalia it 1 13 IM TEC 028 EN_rev 10 2 November 2015 inDOMOHP Platform lif...

Страница 2: ...5 2 4 ORIGINAL MATERIALS FROM LIFTINGITALIA 5 2 5 STRUCTURAL TEST 5 2 6 MAXIMUM STATIC PRESSURE 5 2 7 HYDRAULIC CIRCUIT 5 2 8 BLOCK VALVE 5 2 9 OVERLOAD MANOSTAT 6 2 10 ASCENT AND DESCENT SPEED 6 2 11...

Страница 3: ...due to sharp angles or protruding parts Risk of damage to mechanical parts e g during incorrect installation Fire hazard Hanging load Risk of skin injury Risk of falling No entry Materials to be prot...

Страница 4: ...y each of them contains the requirements to be matched and the way to check them The operations described in this paragraph can be carried out by adequately qualified personnel The below listed operat...

Страница 5: ...mities of the lift MAXIMUM LOAD 2 6 MAXIMUM STATIC PRESSURE Check the maximum static pressure with the maximum load i bring the car to the upper stop and open the valve of the pressure gauge ii Pay at...

Страница 6: ...ecision either fully loaded or empty car i use the landing operation panel for commands ii with a loaded car command an upwards travel letting the lift stop by itself iii open the landing door and wit...

Страница 7: ...ess and hold any operation button the car will descend to the lowest floor so the door can be open vi refresh 2 15 SHAFT CLOSURE The shaft must be closed completely 2 16 COMMANDS Check the correct exe...

Страница 8: ...he shaft wall in front of the entrance ii CAR WITHOUT DOORS the distance between the shaft and the entrances must be max 20 mm valid for the full travel height ii CAR WITH DOORS the horizontal distanc...

Страница 9: ...ximum 1 4 maximum static pressure described in the paragraph 2 4 of this manual v refresh 2 26 PULLEY SAFETY COVERS Check the presence and the correct assembly of the safety covers applied on the pull...

Страница 10: ...ons and humidity and can keep the constant temperature comprised between 5 and 40 C ii the area in front of the cabinet door is clean and its width and height are suffucient for a safe access iii a re...

Страница 11: ...ner ____________________________________________ Address ___________________________________________ ___________________________________________ Ph ______________________ Fax ____________________ Inst...

Страница 12: ...____________________________________ __________________________________________________________________ __________________________________________________________________ Date _______________ Installe...

Страница 13: ..._______________________________________________ __________________________________________________________________ __________________________________________________________________ Date _____________...

Отзывы: