SPECIFICATION
Model
Rated power / frequency
Ice making current
Ice harvest current
Ice cubes number / tray
Protection against electric shock
Water inlet mode
Tap water inlet pressure
Refrigerant / Weight
Insulation materials
Applicable environmental level
Gross / net weight
Product size
DBJ-45
120V/60Hz
2.8A
4.3A
45
1 Level
Tap water / bucket water
100-800KPa
R134a / 0.26lb
Cyclopentane (C5H10)
SN / N
55.3 / 52.4 LBS
14.96*16.53*29.72 INCH
SAFETY PRECAUTIONS
1. The voltage of this appliance is: 120V~ / 60Hz. If the voltage is unstable or with large
fluctuation, please install a voltage regulator.
2. Make sure the appliance is earthed, and ensure effective earthing, as well as the
earth wire must not be connected to the water pipe or gas pipe.
3. In order to protect the compressor, do not start the appliance again within 5 minutes
after power off.
4. Do not connect other appliances to the same socket.
5. If the power cord is damaged, in order to avoid danger, it must be repaired or
replaced by professionals.
6. The electrical control system has a voltage of more than 36V. If maintenance is
required during using, please have it handled by a professional technician.
WARNING:
Do not operate the ice maker when there is a gas leak in its environment. Fire hazard
may occur due to sparks caused by unplugging or plugging or the start-stop controlled by
the temperature controller, the air source should be cut off first, and allow air to circulate.