Lifebreath Lifebreath TFP3000 Скачать руководство пользователя страница 5

info@lifebreath.com

5

Model TFP3000HEPA & TFPC3000HEPA Particle Capture Rate

• Model TFP3000HEPA - 99.97% efficient at .3 microns.
• A human hair is 100 microns wide.
• Spores and pollen are all larger than 8 microns.
• A micron is 1/1000 of a millimetre, or less than 1/2 of 1/10,000 of an

inch.

Note:
Minimum 16"
(406 mm) required 
for service

All duct connections are 7" (178 mm)

OFF/LOW/HIGH

SWITCH

34.25"

870 mm

14.5"

368 mm

14.75"

375 mm

16"

406 mm

FRONT

SIDE

END

Particle Size

(microns)

Percentage Caught

.3 or more

99.7%

Motors and Blowers

2 speed, high efficiency PSC Motor - 150 cfm/75 cfm.

110 watts - 120 VAC - standard three prong plug to receptacle.

The TFP is equipped with a standard power supply on 5’5”

(1.6 meters) cable.

OFF/LOW/HIGH Speed Selector Switch

Select 75 cfm (Low) or 150 cfm (High).

Airflow

150cfm @ .4" WC (High Speed)

75 cfm @ .4" WC (Low Speed)

Collectors

Model TFP3000

- One replaceable TFP collector and one

replaceable HEPA filter

Model TFPC3000HEPA CONSOLE

- One replaceable TFP

collector and one replaceable HEPA filter

• Easy to remove for cleaning and replacement

• Annual inspection recommended

Case

Twenty gauge prepainted galvanized steel (G60) for superior

corrosion resistance

Weight

55 lbs. (24.4 Kgs)

Electrical Codes

Conforms to CSA and UL standards

Mounting the Wholehouse TFP - very flexible

a. Mount to the furnace return

b. Mount between the HRV and the furnace

c. Hang from a joist and duct to the furnace

d. Stand alone installation

Warranty

Units carry a five year warranty on all replacement

parts except the collectors/filters.

Options

65-503R - One replacement TFP Collector

65-502R - One replacement HEPA filter

Optional Installation Kit: Part # 99-TFP

Includes - two 7” Duct Connection Collars

- 12.5’ of 7” Non-insulated Flex Duct

- four Nylon Duct Zip Ties

Specifications

TFP3000HEPA and TFPC3000HEPA

TFP3000HEPA

Console Portable
Model
TFPC3000HEPA

Exhaust

Air

Supply 

Air

Date: ___________________________________________
Tag: _____________________Qty:___________________
Project: _________________________________________
Engineer: _______________________________________

Contractor: ______________________________________
Supplier: ________________________________________
Quote#: _________________________________________
Submitted by: ____________________________________

Содержание Lifebreath TFP3000

Страница 1: ... up 11 Medical prescription 11 Wiring Diagram 12 Table of Contents TFP 3000 0108 LEAVE MANUAL FOR HOMEOWNER NOTE Due to ongoing research and product development specifications ratings and dimensions are subject to change without notice Models TFP3000 TFPC3000 TFP3000HEPA TFPC3000HEPA Operation and Installation Manual Exhaust Air Supply Air Console Portable Models TFPC3000 and TFPC3000HEPA Whole Ho...

Страница 2: ...unting pads for TFPC to stand on Exhaust Air Supply Air Model TFPC3000HEPA HEPA Filter TFP Collector T Replace collector annually Replace collector every 3 years Due to the performance characteristics of the TFP collector the Hepa filter only needs to be replaced every 3 years CONSOLE MODEL 60 TFPC 3000 CAUTION ATTENTION BLUE BLACK BLACK BLACK G Neutral WHITE Line BLACK Ground GREEN HIGH SPEED OFF...

Страница 3: ...ust another filter Airia Energy Systems hold the patent for this TFP technology The TFP series are the only one of its kind How much maintenance is involved How often do the filters need to be replaced As tested under average household dust loading the TFP should be inspected annually Typically the primary collector should be replaced annually and the secondary collector should be replaced every 2...

Страница 4: ...ommended Case Twenty gauge prepainted galvanized steel G60 for superior corrosion resistance Weight 55 lbs 24 4 Kgs Electrical Codes Conforms to CSA and UL standards Mounting the Wholehouse TFP very flexible a Mount to the furnace return b Mount between the HRV and the furnace c Hang from a joist and duct to the furnace d Stand alone installation Warranty Units carry a five year warranty on all re...

Страница 5: ...ning and replacement Annual inspection recommended Case Twenty gauge prepainted galvanized steel G60 for superior corrosion resistance Weight 55 lbs 24 4 Kgs Electrical Codes Conforms to CSA and UL standards Mounting the Wholehouse TFP very flexible a Mount to the furnace return b Mount between the HRV and the furnace c Hang from a joist and duct to the furnace d Stand alone installation Warranty ...

Страница 6: ... 8 32 X 3 4 mounting screws provided through the brackets and into position Tighten and secure 7 TFP should now sit securely against the plenum with the foam in between 8 Cut 2 7 holes in the return air plenum Install ducting to join TFP to the return air plenum Fig 2 NOTE Do not support the weight of the TFP on the duct Duct must be open and not pinched NOTE Due to possible noise transfer through...

Страница 7: ...ith the TFP is acceptable Consult a certified electrician ATTENTION TYPE 1 INSTALLATION Option C Vertical Design Use Option B when Option A is not practical For cedAir Fur nace Return Air Supply Air Air Cleaner The furnace fan and or HRV must operate continuously for Type 1 and Type 2 installations If they do not operate continuously then interlocking them electrically with the TFP is acceptable C...

Страница 8: ...xible ducting should be used on both sides of the TFP Fig 3 This will reduce vibration and noise transfer if present NOTE Please refer to the HRV installation manual for proper ducting of that appliance Breathing T The Breathing T is designed to assist in neutralizing pressure differences which can occur between the HRV and the TFP when joined together The Breathing T should be situated in an area...

Страница 9: ...ler than the size of the port collars 7 on the TFP 4 Ductwork should be kept as short and straight as possible to allow for good air circulation Note For installations of more than one return or supply greater than 5 e s p it is often necessary to add an in line fan to the system as a booster TYPE 3 INSTALLATION Independent Duct System No HRV This installation configuration is recommended for home...

Страница 10: ...10 Épurateur d air Bureau ou salle de classe Espace climatisé Air Cleaner TYPE 3 INSTALLATION Alternative Applications Office or Classroom Application Work Table Application ...

Страница 11: ...replacing the collectors make sure the directional arrows are noted and the collectors are installed correctly Close the door and restart TFP furnace and HRV fan When your TFP is installed with a forced air heating system you are still required to use the recommended furnace filter This may be a good time to inspect this filter as well When new collectors are required call your dealer Model TFP300...

Страница 12: ...d GREEN HIGH SPEED OFF LOW SPEED DEFOND SWITCH 120 VAC 60 Hz FAN MOTOR 1 2 3 TRANSFORMER TERMINAL BLOCK BLACK WHITE BLUE WHITE BLUE BLACK BLACK BLUE RED WHITE RED G GREEN YELLOW 370V 50 60HZ CAPACITOR 10UF DOOR SWITCH RED RED BROWN CAUTION ATTENTION info lifebreath com 12 ...

Отзывы: