TFP (Turbulent Flow Precipitator) Technology removes health

threatening particles from the air far more effectively than most

other residential cleaners. It operates continuously at maximum

efficiency without the need for constant adjustment and cleanout.

Unlike some air cleaners, it introduces absolutely no ozone into

your home. It cleans the air throughout your home, benefiting all

the family, all the time. The TFP allows air to circulate freely,

without putting any extra load on your air distribution system.

Why do I need a TFP Air Cleaner?

The air in today's homes is 3 to 5 times more polluted than outdoor

air creating health problems such as asthma, allergies, headaches,

and fatigue for the home's occupants. The Lifebreath TFP Air

Cleaner will remove 99% of these polluting particles from your

home creating a clean and comfortable environment for you and

your family.

Will I notice a difference in the amount of dust in
my home?

We have received numerous testimonials from satisfied customers

attesting to the significant drop in dust found in the homes where a

TFP is installed.

Does the TFP generate harmful ozone?

The TFP series is an induced airflow system which requires no

electric charge.

Is the TFP a patented unique technology or just
another filter?

Airia Energy Systems hold the patent for this TFP technology.

The TFP series are the only one of its kind.

How much maintenance is involved? How often do
the filters need to be replaced?

As tested under average household dust loading, the TFP should

be inspected annually. Typically the primary collector should be

replaced annually and the secondary collector should be replaced

every 2 years.

Optional Installation Kit: Part# 99-7TFP
Includes:

– two 7” Duct Connection Collars
– 12.5’ of 7” Duct
– four Nylon Duct Zip Ties

Location

The TFP should be installed in a conditioned space with easy

access for maintenance and an annual check up. A TFP is usually

installed in a basement area where air flow noise will be negligible

to the occupants.

1 TFP
4 Mounting Brackets
4 Hanging Straps
2 Collar Connections
4 Port Collar Screws
8 Mounting Bracket Screws
4 Pieces of Mounting Foam
1 Set of Installation/Operating Instructions
1 Wiring Diagram
1 Warranty Card

There are three basic installation options. Select the best method

for your needs.
1. TFP to a Forced Air System; use Return/Return Method

(horizontal or vertical TFP installation)

2. TFP to a Fully Dedicated HRV System

- recommended when you wish to clean the incoming air from

the HRV

3. Stand Alone System – recommended for homes without forced

air systems (ie. radiantly heated homes).

3

Options

Installation

Overview

TFP Questions & Answers

Materials Supplied

Preferred Installation Options

Содержание Lifebreath TFP3000

Страница 1: ... up 11 Medical prescription 11 Wiring Diagram 12 Table of Contents TFP 3000 0108 LEAVE MANUAL FOR HOMEOWNER NOTE Due to ongoing research and product development specifications ratings and dimensions are subject to change without notice Models TFP3000 TFPC3000 TFP3000HEPA TFPC3000HEPA Operation and Installation Manual Exhaust Air Supply Air Console Portable Models TFPC3000 and TFPC3000HEPA Whole Ho...

Страница 2: ...unting pads for TFPC to stand on Exhaust Air Supply Air Model TFPC3000HEPA HEPA Filter TFP Collector T Replace collector annually Replace collector every 3 years Due to the performance characteristics of the TFP collector the Hepa filter only needs to be replaced every 3 years CONSOLE MODEL 60 TFPC 3000 CAUTION ATTENTION BLUE BLACK BLACK BLACK G Neutral WHITE Line BLACK Ground GREEN HIGH SPEED OFF...

Страница 3: ...ust another filter Airia Energy Systems hold the patent for this TFP technology The TFP series are the only one of its kind How much maintenance is involved How often do the filters need to be replaced As tested under average household dust loading the TFP should be inspected annually Typically the primary collector should be replaced annually and the secondary collector should be replaced every 2...

Страница 4: ...ommended Case Twenty gauge prepainted galvanized steel G60 for superior corrosion resistance Weight 55 lbs 24 4 Kgs Electrical Codes Conforms to CSA and UL standards Mounting the Wholehouse TFP very flexible a Mount to the furnace return b Mount between the HRV and the furnace c Hang from a joist and duct to the furnace d Stand alone installation Warranty Units carry a five year warranty on all re...

Страница 5: ...ning and replacement Annual inspection recommended Case Twenty gauge prepainted galvanized steel G60 for superior corrosion resistance Weight 55 lbs 24 4 Kgs Electrical Codes Conforms to CSA and UL standards Mounting the Wholehouse TFP very flexible a Mount to the furnace return b Mount between the HRV and the furnace c Hang from a joist and duct to the furnace d Stand alone installation Warranty ...

Страница 6: ... 8 32 X 3 4 mounting screws provided through the brackets and into position Tighten and secure 7 TFP should now sit securely against the plenum with the foam in between 8 Cut 2 7 holes in the return air plenum Install ducting to join TFP to the return air plenum Fig 2 NOTE Do not support the weight of the TFP on the duct Duct must be open and not pinched NOTE Due to possible noise transfer through...

Страница 7: ...ith the TFP is acceptable Consult a certified electrician ATTENTION TYPE 1 INSTALLATION Option C Vertical Design Use Option B when Option A is not practical For cedAir Fur nace Return Air Supply Air Air Cleaner The furnace fan and or HRV must operate continuously for Type 1 and Type 2 installations If they do not operate continuously then interlocking them electrically with the TFP is acceptable C...

Страница 8: ...xible ducting should be used on both sides of the TFP Fig 3 This will reduce vibration and noise transfer if present NOTE Please refer to the HRV installation manual for proper ducting of that appliance Breathing T The Breathing T is designed to assist in neutralizing pressure differences which can occur between the HRV and the TFP when joined together The Breathing T should be situated in an area...

Страница 9: ...ler than the size of the port collars 7 on the TFP 4 Ductwork should be kept as short and straight as possible to allow for good air circulation Note For installations of more than one return or supply greater than 5 e s p it is often necessary to add an in line fan to the system as a booster TYPE 3 INSTALLATION Independent Duct System No HRV This installation configuration is recommended for home...

Страница 10: ...10 Épurateur d air Bureau ou salle de classe Espace climatisé Air Cleaner TYPE 3 INSTALLATION Alternative Applications Office or Classroom Application Work Table Application ...

Страница 11: ...replacing the collectors make sure the directional arrows are noted and the collectors are installed correctly Close the door and restart TFP furnace and HRV fan When your TFP is installed with a forced air heating system you are still required to use the recommended furnace filter This may be a good time to inspect this filter as well When new collectors are required call your dealer Model TFP300...

Страница 12: ...d GREEN HIGH SPEED OFF LOW SPEED DEFOND SWITCH 120 VAC 60 Hz FAN MOTOR 1 2 3 TRANSFORMER TERMINAL BLOCK BLACK WHITE BLUE WHITE BLUE BLACK BLACK BLUE RED WHITE RED G GREEN YELLOW 370V 50 60HZ CAPACITOR 10UF DOOR SWITCH RED RED BROWN CAUTION ATTENTION info lifebreath com 12 ...

Отзывы: