![Lifebreath CAF-D-L4A-36-P16 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/lifebreath/caf-d-l4a-36-p16/caf-d-l4a-36-p16_operation-sizing-and-installation-manual_1909141020.webp)
20
R W Y G
A/C Unit
Thermostat
To “Y”
To “C”
T30
SW1
T29
T28
RED
O
G
Y
W
R
C
T25
T17
K3
K4
K5
COM
N.O.
K6
COM
N.O.
COM
N.O.
COM
N.O.
T18
T19
T20
RELAY
FEED
T43
SPARE
T26 T27
GRN
YEL
P2
P3
R
24Vac
12Vac Com
Thermostat
DET
C
D
efr
os
t
Fr
ee
ze
Fan Hi
Fan Med
Fan Low
ON
P1
C4
C3
K7
K1
K2
K8
8
7
6
5
4
3
2
1
C2
C1
T3
1
T3
2
T3
3
T3
4
T3
5
T3
6
T3
7
T3
8
T3
9
T4
0
T4
1
T42
Contact 1
N.0. COM N.C. N.0. COM N.C. N.0. COM N.C. N.0 . COM
Contact 2
Contact 3
Contact 4
Digital Controls
DIP SWITCHES TO BE
ADJUSTED BY QUALIFIED
TECHNICIANS ONLY.
N.C
SEUL UN TECHNICIEN
QUALIFIÉ PEUT AJUSTÉ LES
COMMUTATEURS DIP.
CHASSIS
T44
T21
T22
T23
T24
AUX 1
AUX 2
T3
T4
T5
T6
Line/Ligne
T1
T2
T13
T14
T15
T16
Neutral/Neutre
T11
T12
2 AMPS
Standard 24 Volt
Thermostat
Connection
(Thermostats are not avail-
able through Airia)
Thermostat Heat Anticipator Settings
Mechanical Thermostats - start at .5 amp and may need to
be increased depending upon the residual heat left in the
hydronic coil and duct work.
Electronic Thermostats - to be set on electric style heat.
Off Season Circulation Timer
Water is periodically circulated through the space heating
loop during the summer and other periods of infrequent use.
The concern is that water which remains stationary in the
heating loop during the summer may be less than desirable
as domestic hot water when it is returned to the water heater
at system startup in the fall.
Basic Functions
C
- Common
R
- 24 volt Supply
W - Medium or High Fan Relay with Circulation Pump
(The speed depends on Dip Switch # 6 setting)
Y&G- Medium or High Fan Relay
(The speed depends on Dip Switch # 7 setting)
G
- Low Speed Fan Relay
O
- High Speed Fan Relay with Circulation Pump
Function and Controls
Standard Motor
Standard Motor DIP Switch Settings
(DIP #1-8 OFF is Factory Setting)
ON
8
7
6
5
4
3
2
1
DIP #2 to ON will disable the
Off Season Circulation Timer
DIP #6 to ON will select
Medium Speed for heating
(Factory setting is OFF for High
Speed)
DIP #7 to ON will select
Medium Speed for cooling
switch (Factory setting is OFF
for High Speed)
Do not adjust any other DIP switches than
indicated above.
WARNING
Do not energize the CAF until the plumbing is
connected and commissioned. Failure to do so
will damage the pump.
WARNING