3
Top
Side
Front
29.5"
29.5"
19"
47.5"
6"
6"
®
C L E A N A I R F U R N A C E
14"
12"
4"
19"
16"
Duct (coil)
Opening
17.25"
*Ventilation
Supply Air
Inlet
*Ventilation
Exhaust Air
Outlet
22"
*Return
Plenum
Latches
Blower Section
Service Clearance 1'
Service Clearance 3'
Core
Ventilation system has patented aluminum heat
recovery core for energy-efficient ventilation.
Filters
Washable air filters in exhaust and supply air streams of
ventilation section, 1" Pleated in return plenum side.
Case
Prepainted galvanized steel for superior corrosion
resistance.
Dimensions & Clearances
Options
99-186
Weatherhoods, Two - 6" c/w
1/4" mesh screen
99-130W
Remote Wall Mount Dehumidistat
Control 24 VAC only,
99-122
6” Balancing Damper
99-RSK6
6” Backdraft Damper
Warranty
Units carry a lifetime warranty on the heat recovery core and a
five year replacement parts warranty on all other components.
Specifications 18kw = (60,000 BTUH)
Voltage
240 VAC 60 Hz
Hp
1/3
Amps (total)
85
Stages
Single (4 sequence)
Ventilation
6"
Ducts
Return
14" x 22"
Plenum
Supply
17.25" x 16"
Airflow
1350 CFM @ .25 ESP
1180 CFM @ .5 ESP
Ventilation
140 CFM
Airflow
Effectiveness
70%
(HRV)
Note: All connections to be made by qualified contractors.
Net Weight 150 lbs. Shipping Weight 165lbs.
Specifications
60ELE-DF
Содержание 60ELE-DF
Страница 4: ...4 Figure 1 Blower Performance Curve ...
Страница 15: ...15 Date Particulars Maintenance and Service Record ...
Страница 16: ......