Connecting
Optional
Control
- Part #
99-
BC02
The control
may be installed onto a flush mounted 2" x 4" electrical
switch box or it may be surface mounted onto a wall.
Only 1 master control should be installed to a ventilation system
(the Face Plate on this illustration may not be exactly the
same as yours).
ATTENTION
Pay special attention not to damage the Contact
Pins when attaching and detaching the Face Plate.
(Figure B)
RED
GRN
YEL
DET
Digital
Contr
ols
Figure
D
Terminal strip on
Aircom circuit
board
•
Yellow to YEL
•
Red to RED
•
Green to GRN
•
Use 3/20 wire
8
1.
Separate the Face Plate from the Back
Plate by firmly pulling apart (Figure A).
Be careful not to damage Face
Plate Contact Pins.
2.
For mounting the control without a
Decora plate, break off top and
bottom tabs and refer to Figure C for
mounting.
3.
Place the Back Plate of the control in the
desired location on the wall and pencil
mark the top and bottom screw holes
(Figure B or C).
4.
Remove the Back Plate and mark the
center hole for the wires in the middle of
the screw holes. Refer to Figure B or
C for placement.
5.
Cut in a 3/4 in by 1 in oval hole in the
wall to allow for the wire opening and
drill (two) 1/8 in holes for the screws and
wall anchors (Figure B or C).
6.
Pull 3 wire 20 gauge (min.) 100 ft length
(max.), through the opening in the wall.
7.
Connect red, green, and yellow to the
Wiring Terminals located on the Back
Plate (Figure B or C).
8.
Attach the Back Plate to the wall using
the 2 supplied screws and anchors.
9.
Attach the Face Plate to the Back Plate
(Figure A). Note: Be careful to
correctly align the Face Plate to avoid
damaging the Face Plate Contact Pins.
10.
Connect the 3 wire 20 gauge (min.) 100
ft length (max.) to the digital controls
terminal strip located on the Aircom
circuit board (Figure D).
Figure A
Keep top / bottom
vent openings clear
Figure B
1.625"
0.75
"
1
"
1.625"
1/8 in hole for
screw and
anchor
1 in x 3/4 in
for wire
opening
Wiring
Terminals
1/8 in hole
for screw and
anchor
oval hole
Break off tab
Figure C
Alternate Wall Mount
1/8 in hole for
screw and
anchor
1 in x 3/4 in
0.75
"
oval hole
1/8 in
for wire
hole for
opening
screw and
anchor
Wiring
Terminals
Break off tab
1
"
Wire hole
centered
between
screw
holes
Back Plate
Face Plate