58
DYNAMIC
ANCHOR
Minimum
Concrete
Thickness
Minimum Drill
Depth in Concrete
Minimum Concrete
Embedment
Minimum concrete
compressive strength
KH-EZ 3/8”
4-7/8” (124mm)
1/2” beyond anchor
length
3-1/4” (83mm)
3000psi
HUS-H 8mm
120mm (4-3/4”)
10mm beyond anchor
length
75mm (2-3/32”)
20 N/mm2
HSL-3 M/40
4-3/4” (120mm)
1/2” beyond anchor
length
2-13/32” (60mm)
3000psi
HST M 12
140mm (5-1/2”)
10mm beyond anchor
length
70mm (2.8”)
20 N/mm2
Anchor Specifications
Pullout Force
Life Fitness specifies Hilti™ static and dynamic anchors. According to the anchor manufacturer, the recommended
design pullout force (in tension) for the specified anchors, when properly installed in cracked concrete, is provided
in the side table. This table should be used for reference only; for additional and up-to-date information on the
anchor capabilities or the design pullout force in other substrates, please consult Hilti directly at
https://www.us.hilti.com.
SELECTED ANCHOR
DESIGN RESISTANCE IN TENSION
KH-EZ 3/8” x 4”
1535 lb
KH-EZ 3/8” x 5”
1535 lb
HUS-H 8mm x 120mm
3.3 kN
HUS-H 8mm x 140mm
3.3 kN
HSL-3/8 4”
2000 lb
HST M12 x 115/20
8 kN
HST M12 x 195/200
8kN
* Design strength extracted from the Hilti Anchor Fastening Technology Manual issued September 2014.
Tools Required
Adhere to manufacturer’s equipment warnings and guidelines. Follow manufacturer’s instructions for
proper usage.
Floor scanner/rebar detector (optional)
Safety glasses
1” L-shape SDS rotary hammer
Extension cord
1/4” x 12” (6mm x 305mm) carbide drill bit (for 1/4” (6mm) anchors)
Impact wrench
3/8” x 12” (8mm x 305mm) carbide drill bit (for 3/8” (8mm) anchors)
Vacuum (for debris)
WARNING!
Содержание Hammer Strength HD Elite Power Rack
Страница 2: ......
Страница 13: ...10 6 STORAGE BASES AND CABLE STATIONS ...
Страница 14: ...11 7 UPRIGHTS PULL UP BARS AND RACK CONNECTORS ...