54
10
Cable Handling Guide
Cable Connections, Tensioning and Inspection
Cable connections with threaded cable ends are required to be installed and maintained following the specifications
identified below. Failure to follow these specifications can lead to the dislocation of the threaded cable during use and
can cause serious injury. Along with securing the threaded cable end and jam nut, it is important to check the entire
unit and ensure that all hardware is securely fastened and not left loose upon completion of cable installation.
Use of non certified “techs” note: Service warranties may be void if a non-Life Fitness certified technician performs ser-
vice work. Replacement of any strength cables should be performed by a Life Fitness certified technician.
Tensioning Cable
Cables should have enough tension so it stays seated onto the pulley but not so tight that it pulls the head plate off the
weight plates below it.
If headplate has lifted (floating):
1. Loosen the hardware at the terminations until the headplate comes to rest on the weight plate below.
2. Tighten hardware to 20-25 FT-LBS (27.2 - 34.0Nm).
SEATED HEADPLATE
FLOATING HEADPLATE